Companies

Copeland Unclaimed

4776 listing(s) in HVAC Builder's catalog from Copeland's published data, selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; Copeland has not claimed it.

Compressor maps by refrigerant: R407C 636, R448A 508, R407F 443, R407A 435, R404A 343, R449A 332, R134a 239, R454C 232, R410A 230, R507 221, R455A 219, R454A 214, R513A 212, R22 182, R290 145, R454B 101, R450A 32, R1234yf 22, R32 16, R452A 14.

Are you Copeland?

Claim this page from the supplier portal: register as a supplier (company name and contact email), open the Company tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the supplier portal

Listings

All kindsCompressor 182
All marketsNA 105APAC 77EU 77
All tagsR407C 636R448A 508R407F 443R407A 435R404A 343R449A 332R134a 239R454C 232R410A 230R507 221R455A 219R22 182+8 more — search by name instead
SortNewestName A–ZSupplier A–Z

Showing 169–182 of 182

Copeland ZS26KAE-TF5 (R22 scroll, 50 Hz, HT)

R22 compressor — 9.5 kW cooling, 3.16 kW input, COP 3.00 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland ZS26KAE-TF5 (R22 scroll, 60 Hz, HT)

R22 compressor — 11.4 kW cooling, 3.79 kW input, COP 3.00 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Copeland ZS29KAE-TF5 (R22 scroll, 50 Hz, HT)

R22 compressor — 9.5 kW cooling, 3.16 kW input, COP 3.00 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland ZS29KAE-TF5 (R22 scroll, 60 Hz, HT)

R22 compressor — 12.9 kW cooling, 4.14 kW input, COP 3.12 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Copeland ZS33KAE-TF5 (R22 scroll, 50 Hz, HT)

R22 compressor — 12.1 kW cooling, 3.98 kW input, COP 3.04 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland ZS33KAE-TF5 (R22 scroll, 60 Hz, HT)

R22 compressor — 14.5 kW cooling, 4.78 kW input, COP 3.04 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Copeland ZSH09KAE-TF5 (R22 scroll, 50 Hz, MT)

R22 compressor — 3.5 kW cooling, 1.27 kW input, COP 2.76 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland ZSH09KAE-TF5 (R22 scroll, 60 Hz, MT)

R22 compressor — 4.2 kW cooling, 1.52 kW input, COP 2.76 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Copeland ZSH13KAE-TF5 (R22 scroll, 50 Hz, MT)

R22 compressor — 4.8 kW cooling, 1.65 kW input, COP 2.89 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland ZSH13KAE-TF5 (R22 scroll, 60 Hz, MT)

R22 compressor — 5.7 kW cooling, 1.98 kW input, COP 2.89 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Copeland ZSH19KAE-TF5 (R22 scroll, 50 Hz, MT)

R22 compressor — 6.6 kW cooling, 2.20 kW input, COP 3.00 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland ZSH19KAE-TF5 (R22 scroll, 60 Hz, MT)

R22 compressor — 7.9 kW cooling, 2.64 kW input, COP 3.00 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Copeland ZSH20KAE-TF5 (R22 scroll, 50 Hz, MT)

R22 compressor — 7.9 kW cooling, 2.68 kW input, COP 2.95 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland ZSH20KAE-TF5 (R22 scroll, 60 Hz, MT)

R22 compressor — 9.5 kW cooling, 3.22 kW input, COP 2.95 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA
‹ Previous1678

How the model reads against Copeland's data

Compressor maps converted from the vendor's own rating database4 776 mapsevery basis median within 3.2 % of the nomenclature; the vendor's polynomial substituted exactly, never refitted

From the validation page; every row is held by a test.

Worked cases that run Copeland machines

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.

HVAC Builder · engineering results are estimates from catalog data and published correlations: ASHRAE, IAPWS-IF97, AHRI 540, EnergyPlus, CoolProp · weather data: PVGIS © European Union, JRC · contact: leads@hvacbuilder.app · bugs: bugs@hvacbuilder.app · validation · changelog · manufacturers · catalog · tools · Systems · Components · Suppliers · Privacy