Companies

Invotech Unclaimed

1103 listing(s) in HVAC Builder's catalog from Invotech's published data, selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; Invotech has not claimed it.

Compressor maps by refrigerant: R22 350, R404A 220, R407C 162, R410A 132, R448A 56, R449A 56, R452A 56, R134a 55, R454C 8, R455A 8.

Are you Invotech?

Claim this page from the supplier portal: register as a supplier (company name and contact email), open the Company tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the supplier portal

Listings

All kindsCompressor 422
All marketsNA 681EU 422
All tagsR22 119R404A 72R407C 57R410A 55R448A 28R449A 28R452A 28R134a 19R454C 8R455A 8
SortNewestName A–ZSupplier A–Z

Showing 361–384 of 422

Invotech YW102T2-100 (R407C heat-pump water heater scroll, 50 Hz, 220 V 1P)

R407C compressor — 10.8 kW cooling, 3.61 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · EU

Invotech YW110A1-100 (R22 heat-pump water heater scroll, 50 Hz, 380 V 3P)

R22 compressor — 12.1 kW cooling, 3.87 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU

Invotech YW110A2-100 (R22 heat-pump water heater scroll, 50 Hz, 220 V 1P)

R22 compressor — 12.1 kW cooling, 3.89 kW input, COP 3.11 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU

Invotech YW110C1-100 (R410A heat-pump water heater scroll, 50 Hz, 380 V 3P)

R410A compressor — 12.6 kW cooling, 4.29 kW input, COP 2.93 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU

Invotech YW110C2-100 (R410A heat-pump water heater scroll, 50 Hz, 220 V 1P)

R410A compressor — 12.6 kW cooling, 4.40 kW input, COP 2.86 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU

Invotech YW110T1-100 (R407C heat-pump water heater scroll, 50 Hz, 380 V 3P)

R407C compressor — 11.6 kW cooling, 3.91 kW input, COP 2.98 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · EU

Invotech YW110T2-100 (R407C heat-pump water heater scroll, 50 Hz, 220 V 1P)

R407C compressor — 11.6 kW cooling, 3.93 kW input, COP 2.96 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · EU

Invotech YW120J1-100 (R134a heat-pump water heater scroll, 50 Hz, 380 V 3P)

R134a compressor — 11.2 kW cooling, 3.36 kW input, COP 3.34 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · EU

Invotech YW132J1-100 (R134a heat-pump water heater scroll, 50 Hz, 380 V 3P)

R134a compressor — 13.0 kW cooling, 3.95 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · EU

Invotech YW135A1-100 (R22 heat-pump water heater scroll, 50 Hz, 380 V 3P)

R22 compressor — 14.9 kW cooling, 4.61 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU

Invotech YW135A2-100 (R22 heat-pump water heater scroll, 50 Hz, 220 V 1P)

R22 compressor — 14.9 kW cooling, 4.78 kW input, COP 3.11 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU

Invotech YW135C1-100 (R410A heat-pump water heater scroll, 50 Hz, 380 V 3P)

R410A compressor — 15.4 kW cooling, 5.17 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU

Invotech YW135C2-100 (R410A heat-pump water heater scroll, 50 Hz, 220 V 1P)

R410A compressor — 15.4 kW cooling, 5.34 kW input, COP 2.90 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU

Invotech YW135T1-100 (R407C heat-pump water heater scroll, 50 Hz, 380 V 3P)

R407C compressor — 14.3 kW cooling, 4.65 kW input, COP 3.07 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · EU

Invotech YW135T2-100 (R407C heat-pump water heater scroll, 50 Hz, 220 V 1P)

R407C compressor — 14.3 kW cooling, 4.82 kW input, COP 2.96 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · EU

Invotech YW140J1-100 (R134a heat-pump water heater scroll, 50 Hz, 380 V 3P)

R134a compressor — 13.3 kW cooling, 4.10 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · EU

Invotech YW152A2-100 (R22 heat-pump water heater scroll, 50 Hz, 220 V 1P)

R22 compressor — 16.7 kW cooling, 5.33 kW input, COP 3.14 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU

Invotech YW152C2-100 (R410A heat-pump water heater scroll, 50 Hz, 220 V 1P)

R410A compressor — 16.0 kW cooling, 5.53 kW input, COP 2.90 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU

Invotech YW152T2-100 (R407C heat-pump water heater scroll, 50 Hz, 220 V 1P)

R407C compressor — 16.1 kW cooling, 5.38 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · EU

Invotech YW155J1-100 (R134a heat-pump water heater scroll, 50 Hz, 380 V 3P)

R134a compressor — 14.4 kW cooling, 4.40 kW input, COP 3.27 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · EU

Invotech YW160A1-100 (R22 heat-pump water heater scroll, 50 Hz, 380 V 3P)

R22 compressor — 17.6 kW cooling, 5.46 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU

Invotech YW160C1-100 (R410A heat-pump water heater scroll, 50 Hz, 380 V 3P)

R410A compressor — 17.7 kW cooling, 5.91 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU

Invotech YW160T1-100 (R407C heat-pump water heater scroll, 50 Hz, 380 V 3P)

R407C compressor — 16.9 kW cooling, 5.51 kW input, COP 3.07 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · EU

Invotech YW180J1-100 (R134a heat-pump water heater scroll, 50 Hz, 380 V 3P)

R134a compressor — 17.2 kW cooling, 5.29 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · EU
‹ Previous11415161718Next ›

How the model reads against Invotech's data

Invotech scroll maps read from the Invowin selection tool's own database1 103 maps (R22, R410A, R404A, R407C, R134a, R448A, R449A, R452A, R455A, R454C; 50 and 60 Hz)nomenclature median +0.5 %, worst 5.1 %; the tool's SI cubics carried exactly, ×1000 and ÷3600; 990 flow sets close within 15 %, 113 whole low-temperature families sit at a flat 0.76–0.85 of Q/Δh and ship without their flow set, each recorded with its ratio

From the validation page; every row is held by a test.

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.

HVAC Builder · engineering results are estimates from catalog data and published correlations: ASHRAE, IAPWS-IF97, AHRI 540, EnergyPlus, CoolProp · weather data: PVGIS © European Union, JRC · contact: leads@hvacbuilder.app · bugs: bugs@hvacbuilder.app · validation · changelog · manufacturers · catalog · tools · Systems · Components · Suppliers · Privacy