1103 listing(s) in HVAC Builder's catalog from Invotech's published data, selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; Invotech has not claimed it.

Compressor maps by refrigerant: R22 350, R404A 220, R407C 162, R410A 132, R448A 56, R449A 56, R452A 56, R134a 55, R454C 8, R455A 8.

Are you Invotech?

Claim this page from the supplier portal: register as a supplier (company name and contact email), open the Company tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the supplier portal

Listings

All kindsCompressor 55
All marketsNA 36EU 19
All tagsR22 350R404A 220R407C 162R410A 132R448A 56R449A 56R452A 56R134a 55R454C 8R455A 8
SortNewestName A–ZSupplier A–Z

Showing 25–48 of 55

Invotech YW180J1-100 (R134a heat-pump water heater scroll, 50 Hz, 380 V 3P)

R134a compressor — 17.2 kW cooling, 5.29 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · EU

Invotech YW180J1-100 (R134a heat-pump water heater scroll, 60 Hz, 460 V 3P)

R134a compressor — 20.6 kW cooling, 6.28 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · NA

Invotech YW180J5-100 (R134a heat-pump water heater scroll, 60 Hz, 380 V 3P)

R134a compressor — 20.6 kW cooling, 6.28 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · NA

Invotech YW180J7-100 (R134a heat-pump water heater scroll, 60 Hz, 220 V 3P)

R134a compressor — 20.6 kW cooling, 6.28 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · NA

Invotech YW180J8-100 (R134a heat-pump water heater scroll, 60 Hz, 575 V 3P)

R134a compressor — 20.6 kW cooling, 6.28 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · NA

Invotech YW200J1-100 (R134a heat-pump water heater scroll, 50 Hz, 380 V 3P)

R134a compressor — 20.0 kW cooling, 6.01 kW input, COP 3.32 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · EU

Invotech YW200J1-100 (R134a heat-pump water heater scroll, 60 Hz, 460 V 3P)

R134a compressor — 24.0 kW cooling, 7.20 kW input, COP 3.33 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · NA

Invotech YW200J5-100 (R134a heat-pump water heater scroll, 60 Hz, 380 V 3P)

R134a compressor — 24.0 kW cooling, 7.20 kW input, COP 3.33 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · NA

Invotech YW200J7-100 (R134a heat-pump water heater scroll, 60 Hz, 220 V 3P)

R134a compressor — 24.0 kW cooling, 7.20 kW input, COP 3.33 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · NA

Invotech YW200J8-100 (R134a heat-pump water heater scroll, 60 Hz, 575 V 3P)

R134a compressor — 24.0 kW cooling, 7.20 kW input, COP 3.33 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · NA

Invotech YW240J1-100 (R134a heat-pump water heater scroll, 50 Hz, 380 V 3P)

R134a compressor — 22.4 kW cooling, 6.76 kW input, COP 3.32 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · EU

Invotech YW240J1-100 (R134a heat-pump water heater scroll, 60 Hz, 460 V 3P)

R134a compressor — 26.9 kW cooling, 8.04 kW input, COP 3.35 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · NA

Invotech YW240J5-100 (R134a heat-pump water heater scroll, 60 Hz, 380 V 3P)

R134a compressor — 26.9 kW cooling, 8.04 kW input, COP 3.35 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · NA

Invotech YW240J7-100 (R134a heat-pump water heater scroll, 60 Hz, 220 V 3P)

R134a compressor — 26.9 kW cooling, 8.04 kW input, COP 3.35 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · NA

Invotech YW240J8-100 (R134a heat-pump water heater scroll, 60 Hz, 575 V 3P)

R134a compressor — 26.9 kW cooling, 8.04 kW input, COP 3.35 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · NA

Invotech YW290J1-100 (R134a heat-pump water heater scroll, 50 Hz, 380 V 3P)

R134a compressor — 30.3 kW cooling, 8.79 kW input, COP 3.44 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · EU

Invotech YW38J1-100 (R134a heat-pump water heater scroll, 50 Hz, 380 V 3P)

R134a compressor — 3.7 kW cooling, 1.32 kW input, COP 2.84 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · EU

Invotech YW38J1-100 (R134a heat-pump water heater scroll, 60 Hz, 460 V 3P)

R134a compressor — 4.5 kW cooling, 1.54 kW input, COP 2.93 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · NA

Invotech YW38J2-102 (R134a heat-pump water heater scroll, 50 Hz, 220 V 1P)

R134a compressor — 3.7 kW cooling, 1.39 kW input, COP 2.69 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · EU

Invotech YW390J1-100 (R134a heat-pump water heater scroll, 50 Hz, 380 V 3P)

R134a compressor — 39.8 kW cooling, 11.89 kW input, COP 3.35 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · EU

Invotech YW470J1-100 (R134a heat-pump water heater scroll, 50 Hz, 380 V 3P)

R134a compressor — 45.8 kW cooling, 13.77 kW input, COP 3.33 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · EU

Invotech YW55J1-100 (R134a heat-pump water heater scroll, 50 Hz, 380 V 3P)

R134a compressor — 5.3 kW cooling, 1.60 kW input, COP 3.29 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · EU

Invotech YW55J1-100 (R134a heat-pump water heater scroll, 60 Hz, 460 V 3P)

R134a compressor — 6.3 kW cooling, 2.00 kW input, COP 3.15 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · NA

Invotech YW55J2-100 (R134a heat-pump water heater scroll, 50 Hz, 220 V 1P)

R134a compressor — 5.3 kW cooling, 1.70 kW input, COP 3.10 at the AHRI 7.2/54.4 °C rating point.

catalogR134a
Compressor · EU
‹ Previous123Next ›

How the model reads against Invotech's data

Invotech scroll maps read from the Invowin selection tool's own database1 103 maps (R22, R410A, R404A, R407C, R134a, R448A, R449A, R452A, R455A, R454C; 50 and 60 Hz)nomenclature median +0.5 %, worst 5.1 %; the tool's SI cubics carried exactly, ×1000 and ÷3600; 990 flow sets close within 15 %, 113 whole low-temperature families sit at a flat 0.76–0.85 of Q/Δh and ship without their flow set, each recorded with its ratio

From the validation page; every row is held by a test.

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.

HVAC Builder · engineering results are estimates from catalog data and published correlations: ASHRAE, IAPWS-IF97, AHRI 540, EnergyPlus, CoolProp · weather data: PVGIS © European Union, JRC · contact: leads@hvacbuilder.app · bugs: bugs@hvacbuilder.app · validation · changelog · manufacturers · catalog · tools · Systems · Components · Suppliers · Privacy