Companies

Invotech Unclaimed

1103 listing(s) in HVAC Builder's catalog from Invotech's published data, selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; Invotech has not claimed it.

Compressor maps by refrigerant: R22 350, R404A 220, R407C 162, R410A 132, R448A 56, R449A 56, R452A 56, R134a 55, R454C 8, R455A 8.

Are you Invotech?

Claim this page from the supplier portal: register as a supplier (company name and contact email), open the Company tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the supplier portal

Listings

All kindsCompressor 1103
All marketsNA 681EU 422
All tagsR22 350R404A 220R407C 162R410A 132R448A 56R449A 56R452A 56R134a 55R454C 8R455A 8
SortNewestName A–ZSupplier A–Z

Showing 817–840 of 1103

Invotech YM86E3G-100 (R452A medium-temperature refrigeration scroll, 60 Hz, 220 V 1P)

R452A compressor — 15.6 kW cooling, 6.61 kW input, COP 2.36 at the AHRI 7.2/54.4 °C rating point.

catalogR452A
Compressor · NA

Invotech YM86E5G-100 (R404A medium-temperature refrigeration scroll, 60 Hz, 380 V 3P)

R404A compressor — 16.0 kW cooling, 6.21 kW input, COP 2.58 at the AHRI 7.2/54.4 °C rating point.

catalogR404A
Compressor · NA

Invotech YM86E6G-100 (R404A medium-temperature refrigeration scroll, 50 Hz, 220 V 3P)

R404A compressor — 13.3 kW cooling, 5.18 kW input, COP 2.58 at the AHRI 7.2/54.4 °C rating point.

catalogR404A
Compressor · EU

Invotech YM86E7G-100 (R404A medium-temperature refrigeration scroll, 60 Hz, 220 V 3P)

R404A compressor — 16.0 kW cooling, 6.21 kW input, COP 2.58 at the AHRI 7.2/54.4 °C rating point.

catalogR404A
Compressor · NA

Invotech YM86E7G-100 (R448A medium-temperature refrigeration scroll, 60 Hz, 220 V 3P)

R448A compressor — 16.6 kW cooling, 6.18 kW input, COP 2.69 at the AHRI 7.2/54.4 °C rating point.

catalogR448A
Compressor · NA

Invotech YM86E7G-100 (R449A medium-temperature refrigeration scroll, 60 Hz, 220 V 3P)

R449A compressor — 16.6 kW cooling, 6.18 kW input, COP 2.69 at the AHRI 7.2/54.4 °C rating point.

catalogR449A
Compressor · NA

Invotech YM86E7G-100 (R452A medium-temperature refrigeration scroll, 60 Hz, 220 V 3P)

R452A compressor — 15.7 kW cooling, 6.23 kW input, COP 2.52 at the AHRI 7.2/54.4 °C rating point.

catalogR452A
Compressor · NA

Invotech YM86E8G-100 (R404A medium-temperature refrigeration scroll, 60 Hz, 575 V 3P)

R404A compressor — 16.0 kW cooling, 6.21 kW input, COP 2.58 at the AHRI 7.2/54.4 °C rating point.

catalogR404A
Compressor · NA

Invotech YM86U1G-100 (R454C medium-temperature refrigeration scroll, 50 Hz, 380 V 3P)

R454C compressor — 13.0 kW cooling, 4.14 kW input, COP 3.14 at the AHRI 7.2/54.4 °C rating point.

catalogR454C
Compressor · EU

Invotech YM86U1G-100 (R455A medium-temperature refrigeration scroll, 50 Hz, 380 V 3P)

R455A compressor — 14.2 kW cooling, 4.52 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point.

catalogR455A
Compressor · EU

Invotech YSF100A1G-V100 (R22 low-temperature freezing scroll, 50 Hz, 380 V 3P)

R22 compressor — 33.8 kW cooling, 12.59 kW input, COP 2.68 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU

Invotech YSF100A4G-V100 (R22 low-temperature freezing scroll, 60 Hz, 460 V 3P)

R22 compressor — 40.2 kW cooling, 15.35 kW input, COP 2.62 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Invotech YSF100A5G-V100 (R22 low-temperature freezing scroll, 60 Hz, 380 V 3P)

R22 compressor — 40.5 kW cooling, 15.03 kW input, COP 2.70 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Invotech YSF100A7G-V100 (R22 low-temperature freezing scroll, 60 Hz, 220 V 3P)

R22 compressor — 40.5 kW cooling, 15.03 kW input, COP 2.70 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Invotech YSF100E1G-V100 (R404A low-temperature freezing scroll, 50 Hz, 380 V 3P)

R404A compressor — 34.3 kW cooling, 13.41 kW input, COP 2.56 at the AHRI 7.2/54.4 °C rating point.

catalogR404A
Compressor · EU

Invotech YSF100E4G-V100 (R404A low-temperature freezing scroll, 60 Hz, 460 V 3P)

R404A compressor — 40.0 kW cooling, 16.75 kW input, COP 2.39 at the AHRI 7.2/54.4 °C rating point.

catalogR404A
Compressor · NA

Invotech YSF100E5G-V100 (R404A low-temperature freezing scroll, 60 Hz, 380 V 3P)

R404A compressor — 41.2 kW cooling, 16.13 kW input, COP 2.55 at the AHRI 7.2/54.4 °C rating point.

catalogR404A
Compressor · NA

Invotech YSF100E7G-V100 (R404A low-temperature freezing scroll, 60 Hz, 220 V 3P)

R404A compressor — 41.2 kW cooling, 16.13 kW input, COP 2.55 at the AHRI 7.2/54.4 °C rating point.

catalogR404A
Compressor · NA

Invotech YSF125A1G-V100 (R22 low-temperature freezing scroll, 50 Hz, 380 V 3P)

R22 compressor — 41.7 kW cooling, 15.40 kW input, COP 2.71 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU

Invotech YSF125A4G-V100 (R22 low-temperature freezing scroll, 60 Hz, 460 V 3P)

R22 compressor — 49.8 kW cooling, 19.00 kW input, COP 2.62 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Invotech YSF125E1G-V100 (R404A low-temperature freezing scroll, 50 Hz, 380 V 3P)

R404A compressor — 42.4 kW cooling, 16.65 kW input, COP 2.55 at the AHRI 7.2/54.4 °C rating point.

catalogR404A
Compressor · EU

Invotech YSF125E4G-V100 (R404A low-temperature freezing scroll, 60 Hz, 460 V 3P)

R404A compressor — 49.5 kW cooling, 20.73 kW input, COP 2.39 at the AHRI 7.2/54.4 °C rating point.

catalogR404A
Compressor · NA

Invotech YSF60A1G-V100 (R22 low-temperature freezing scroll, 50 Hz, 380 V 3P)

R22 compressor — 19.8 kW cooling, 7.41 kW input, COP 2.67 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU

Invotech YSF60A4G-V100 (R22 low-temperature freezing scroll, 60 Hz, 460 V 3P)

R22 compressor — 23.6 kW cooling, 9.18 kW input, COP 2.57 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA
‹ Previous1333435363746Next ›

How the model reads against Invotech's data

Invotech scroll maps read from the Invowin selection tool's own database1 103 maps (R22, R410A, R404A, R407C, R134a, R448A, R449A, R452A, R455A, R454C; 50 and 60 Hz)nomenclature median +0.5 %, worst 5.1 %; the tool's SI cubics carried exactly, ×1000 and ÷3600; 990 flow sets close within 15 %, 113 whole low-temperature families sit at a flat 0.76–0.85 of Q/Δh and ship without their flow set, each recorded with its ratio

From the validation page; every row is held by a test.

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.

HVAC Builder · engineering results are estimates from catalog data and published correlations: ASHRAE, IAPWS-IF97, AHRI 540, EnergyPlus, CoolProp · weather data: PVGIS © European Union, JRC · contact: leads@hvacbuilder.app · bugs: bugs@hvacbuilder.app · validation · changelog · manufacturers · catalog · tools · Systems · Components · Suppliers · Privacy