Companies

Invotech Unclaimed

1103 listing(s) in HVAC Builder's catalog from Invotech's published data, selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; Invotech has not claimed it.

Compressor maps by refrigerant: R22 350, R404A 220, R407C 162, R410A 132, R448A 56, R449A 56, R452A 56, R134a 55, R454C 8, R455A 8.

Are you Invotech?

Claim this page from the supplier portal: register as a supplier (company name and contact email), open the Company tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the supplier portal

Listings

All kindsCompressor 162
All marketsNA 105EU 57
All tagsR22 350R404A 220R407C 162R410A 132R448A 56R449A 56R452A 56R134a 55R454C 8R455A 8
SortNewestName A–ZSupplier A–Z

Showing 25–48 of 162

Invotech YH133T1-100 (R407C air-conditioning scroll, 50 Hz, 380 V 3P)

R407C compressor — 12.8 kW cooling, 3.91 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · EU

Invotech YH133T1-100 (R407C air-conditioning scroll, 60 Hz, 460 V 3P)

R407C compressor — 15.4 kW cooling, 4.70 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH133T2-100 (R407C air-conditioning scroll, 50 Hz, 220 V 1P)

R407C compressor — 12.8 kW cooling, 4.10 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · EU

Invotech YH133T3-100 (R407C air-conditioning scroll, 60 Hz, 220 V 1P)

R407C compressor — 15.4 kW cooling, 4.92 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH133T5-100 (R407C air-conditioning scroll, 60 Hz, 380 V 3P)

R407C compressor — 15.4 kW cooling, 4.70 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH133T6-100 (R407C air-conditioning scroll, 50 Hz, 220 V 3P)

R407C compressor — 12.8 kW cooling, 3.91 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · EU

Invotech YH133T7-100 (R407C air-conditioning scroll, 60 Hz, 220 V 3P)

R407C compressor — 15.4 kW cooling, 4.70 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH133T8-100 (R407C air-conditioning scroll, 60 Hz, 575 V 3P)

R407C compressor — 15.4 kW cooling, 4.70 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH140T1-100 (R407C air-conditioning scroll, 50 Hz, 380 V 3P)

R407C compressor — 13.5 kW cooling, 4.16 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · EU

Invotech YH140T1-100 (R407C air-conditioning scroll, 60 Hz, 460 V 3P)

R407C compressor — 16.2 kW cooling, 4.99 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH140T2-100 (R407C air-conditioning scroll, 50 Hz, 220 V 1P)

R407C compressor — 13.5 kW cooling, 4.31 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · EU

Invotech YH140T3-100 (R407C air-conditioning scroll, 60 Hz, 220 V 1P)

R407C compressor — 16.2 kW cooling, 5.18 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH140T5-100 (R407C air-conditioning scroll, 60 Hz, 380 V 3P)

R407C compressor — 16.2 kW cooling, 4.99 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH140T6-100 (R407C air-conditioning scroll, 50 Hz, 220 V 3P)

R407C compressor — 13.5 kW cooling, 4.16 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · EU

Invotech YH140T7-100 (R407C air-conditioning scroll, 60 Hz, 220 V 3P)

R407C compressor — 16.2 kW cooling, 4.99 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH140T8-100 (R407C air-conditioning scroll, 60 Hz, 575 V 3P)

R407C compressor — 16.2 kW cooling, 4.99 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH150T1-100 (R407C air-conditioning scroll, 50 Hz, 380 V 3P)

R407C compressor — 14.5 kW cooling, 4.45 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · EU

Invotech YH150T1-100 (R407C air-conditioning scroll, 60 Hz, 460 V 3P)

R407C compressor — 17.4 kW cooling, 5.34 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH150T2-100 (R407C air-conditioning scroll, 50 Hz, 220 V 1P)

R407C compressor — 14.5 kW cooling, 4.62 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · EU

Invotech YH150T3-100 (R407C air-conditioning scroll, 60 Hz, 220 V 1P)

R407C compressor — 17.4 kW cooling, 5.55 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH150T5-100 (R407C air-conditioning scroll, 60 Hz, 380 V 3P)

R407C compressor — 17.4 kW cooling, 5.34 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH150T6-100 (R407C air-conditioning scroll, 50 Hz, 220 V 3P)

R407C compressor — 14.5 kW cooling, 4.45 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · EU

Invotech YH150T7-100 (R407C air-conditioning scroll, 60 Hz, 220 V 3P)

R407C compressor — 17.4 kW cooling, 5.34 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH150T8-100 (R407C air-conditioning scroll, 60 Hz, 575 V 3P)

R407C compressor — 17.4 kW cooling, 5.34 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA
‹ Previous12347Next ›

How the model reads against Invotech's data

Invotech scroll maps read from the Invowin selection tool's own database1 103 maps (R22, R410A, R404A, R407C, R134a, R448A, R449A, R452A, R455A, R454C; 50 and 60 Hz)nomenclature median +0.5 %, worst 5.1 %; the tool's SI cubics carried exactly, ×1000 and ÷3600; 990 flow sets close within 15 %, 113 whole low-temperature families sit at a flat 0.76–0.85 of Q/Δh and ship without their flow set, each recorded with its ratio

From the validation page; every row is held by a test.

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.

HVAC Builder · engineering results are estimates from catalog data and published correlations: ASHRAE, IAPWS-IF97, AHRI 540, EnergyPlus, CoolProp · weather data: PVGIS © European Union, JRC · contact: leads@hvacbuilder.app · bugs: bugs@hvacbuilder.app · validation · changelog · manufacturers · catalog · tools · Systems · Components · Suppliers · Privacy