1103 listing(s) in HVAC Builder's catalog from Invotech's published data, selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; Invotech has not claimed it.
Compressor maps by refrigerant: R22 350, R404A 220, R407C 162, R410A 132, R448A 56, R449A 56, R452A 56, R134a 55, R454C 8, R455A 8.
Claim this page from the supplier portal: register as a supplier (company name and contact email), open the Company tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the supplier portal
Showing 145–168 of 681
R404A compressor — 22.7 kW cooling, 10.07 kW input, COP 2.26 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 22.7 kW cooling, 10.07 kW input, COP 2.26 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 22.7 kW cooling, 10.07 kW input, COP 2.26 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 26.7 kW cooling, 11.38 kW input, COP 2.34 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 26.7 kW cooling, 11.38 kW input, COP 2.34 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 26.7 kW cooling, 11.38 kW input, COP 2.34 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 30.9 kW cooling, 12.82 kW input, COP 2.41 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 30.9 kW cooling, 12.82 kW input, COP 2.41 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 30.9 kW cooling, 12.82 kW input, COP 2.41 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 35.0 kW cooling, 14.48 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 35.0 kW cooling, 14.48 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 35.0 kW cooling, 14.48 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 12.8 kW cooling, 3.83 kW input, COP 3.35 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 12.8 kW cooling, 3.92 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 12.8 kW cooling, 3.83 kW input, COP 3.35 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 12.8 kW cooling, 3.83 kW input, COP 3.35 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 12.8 kW cooling, 3.83 kW input, COP 3.35 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 12.3 kW cooling, 3.87 kW input, COP 3.19 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 12.3 kW cooling, 3.96 kW input, COP 3.11 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 12.3 kW cooling, 3.87 kW input, COP 3.19 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 12.3 kW cooling, 3.87 kW input, COP 3.19 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 12.3 kW cooling, 3.87 kW input, COP 3.19 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 14.4 kW cooling, 4.25 kW input, COP 3.38 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 14.4 kW cooling, 4.38 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.
| Invotech scroll maps read from the Invowin selection tool's own database | 1 103 maps (R22, R410A, R404A, R407C, R134a, R448A, R449A, R452A, R455A, R454C; 50 and 60 Hz) | nomenclature median +0.5 %, worst 5.1 %; the tool's SI cubics carried exactly, ×1000 and ÷3600; 990 flow sets close within 15 %, 113 whole low-temperature families sit at a flat 0.76–0.85 of Q/Δh and ship without their flow set, each recorded with its ratio |
From the validation page; every row is held by a test.
Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.