Companies

Invotech Unclaimed

1103 listing(s) in HVAC Builder's catalog from Invotech's published data, selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; Invotech has not claimed it.

Compressor maps by refrigerant: R22 350, R404A 220, R407C 162, R410A 132, R448A 56, R449A 56, R452A 56, R134a 55, R454C 8, R455A 8.

Are you Invotech?

Claim this page from the supplier portal: register as a supplier (company name and contact email), open the Company tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the supplier portal

Listings

All kindsCompressor 681
All marketsNA 681EU 422
All tagsR22 231R404A 148R407C 105R410A 77R134a 36R448A 28R449A 28R452A 28
SortNewestName A–ZSupplier A–Z

Showing 193–216 of 681

Invotech YH128T3-100 (R407C air-conditioning scroll, 60 Hz, 220 V 1P)

R407C compressor — 14.8 kW cooling, 4.68 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH128T5-100 (R407C air-conditioning scroll, 60 Hz, 380 V 3P)

R407C compressor — 14.8 kW cooling, 4.53 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH128T7-100 (R407C air-conditioning scroll, 60 Hz, 220 V 3P)

R407C compressor — 14.8 kW cooling, 4.53 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH128T8-100 (R407C air-conditioning scroll, 60 Hz, 575 V 3P)

R407C compressor — 14.8 kW cooling, 4.53 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH133A1-100 (R22 air-conditioning scroll, 60 Hz, 460 V 3P)

R22 compressor — 16.1 kW cooling, 4.66 kW input, COP 3.45 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Invotech YH133A3-100 (R22 air-conditioning scroll, 60 Hz, 220 V 1P)

R22 compressor — 16.1 kW cooling, 4.88 kW input, COP 3.30 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Invotech YH133A5-100 (R22 air-conditioning scroll, 60 Hz, 380 V 3P)

R22 compressor — 16.1 kW cooling, 4.66 kW input, COP 3.45 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Invotech YH133A7-100 (R22 air-conditioning scroll, 60 Hz, 220 V 3P)

R22 compressor — 16.1 kW cooling, 4.66 kW input, COP 3.45 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Invotech YH133A8-100 (R22 air-conditioning scroll, 60 Hz, 575 V 3P)

R22 compressor — 16.1 kW cooling, 4.66 kW input, COP 3.45 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Invotech YH133T1-100 (R407C air-conditioning scroll, 60 Hz, 460 V 3P)

R407C compressor — 15.4 kW cooling, 4.70 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH133T3-100 (R407C air-conditioning scroll, 60 Hz, 220 V 1P)

R407C compressor — 15.4 kW cooling, 4.92 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH133T5-100 (R407C air-conditioning scroll, 60 Hz, 380 V 3P)

R407C compressor — 15.4 kW cooling, 4.70 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH133T7-100 (R407C air-conditioning scroll, 60 Hz, 220 V 3P)

R407C compressor — 15.4 kW cooling, 4.70 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH133T8-100 (R407C air-conditioning scroll, 60 Hz, 575 V 3P)

R407C compressor — 15.4 kW cooling, 4.70 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH140A1-100 (R22 air-conditioning scroll, 60 Hz, 460 V 3P)

R22 compressor — 16.9 kW cooling, 4.94 kW input, COP 3.42 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Invotech YH140A3-100 (R22 air-conditioning scroll, 60 Hz, 220 V 1P)

R22 compressor — 16.9 kW cooling, 5.13 kW input, COP 3.30 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Invotech YH140A5-100 (R22 air-conditioning scroll, 60 Hz, 380 V 3P)

R22 compressor — 16.9 kW cooling, 4.94 kW input, COP 3.42 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Invotech YH140A7-100 (R22 air-conditioning scroll, 60 Hz, 220 V 3P)

R22 compressor — 16.9 kW cooling, 4.94 kW input, COP 3.42 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Invotech YH140A8-100 (R22 air-conditioning scroll, 60 Hz, 575 V 3P)

R22 compressor — 16.9 kW cooling, 4.94 kW input, COP 3.42 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · NA

Invotech YH140T1-100 (R407C air-conditioning scroll, 60 Hz, 460 V 3P)

R407C compressor — 16.2 kW cooling, 4.99 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH140T3-100 (R407C air-conditioning scroll, 60 Hz, 220 V 1P)

R407C compressor — 16.2 kW cooling, 5.18 kW input, COP 3.13 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH140T5-100 (R407C air-conditioning scroll, 60 Hz, 380 V 3P)

R407C compressor — 16.2 kW cooling, 4.99 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH140T7-100 (R407C air-conditioning scroll, 60 Hz, 220 V 3P)

R407C compressor — 16.2 kW cooling, 4.99 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Invotech YH140T8-100 (R407C air-conditioning scroll, 60 Hz, 575 V 3P)

R407C compressor — 16.2 kW cooling, 4.99 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA
‹ Previous1789101129Next ›

How the model reads against Invotech's data

Invotech scroll maps read from the Invowin selection tool's own database1 103 maps (R22, R410A, R404A, R407C, R134a, R448A, R449A, R452A, R455A, R454C; 50 and 60 Hz)nomenclature median +0.5 %, worst 5.1 %; the tool's SI cubics carried exactly, ×1000 and ÷3600; 990 flow sets close within 15 %, 113 whole low-temperature families sit at a flat 0.76–0.85 of Q/Δh and ship without their flow set, each recorded with its ratio

From the validation page; every row is held by a test.

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.

HVAC Builder · engineering results are estimates from catalog data and published correlations: ASHRAE, IAPWS-IF97, AHRI 540, EnergyPlus, CoolProp · weather data: PVGIS © European Union, JRC · contact: leads@hvacbuilder.app · bugs: bugs@hvacbuilder.app · validation · changelog · manufacturers · catalog · tools · Systems · Components · Suppliers · Privacy