Companies

Copeland Unclaimed

4776 listing(s) in HVAC Builder's catalog from Copeland's published data, selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; Copeland has not claimed it.

Compressor maps by refrigerant: R407C 636, R448A 508, R407F 443, R407A 435, R404A 343, R449A 332, R134a 239, R454C 232, R410A 230, R507 221, R455A 219, R454A 214, R513A 212, R22 182, R290 145, R454B 101, R450A 32, R1234yf 22, R32 16, R452A 14.

Are you Copeland?

Claim this page from the supplier portal: register as a supplier (company name and contact email), open the Company tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the supplier portal

Listings

All kindsCompressor 1737
All marketsNA 2995APAC 1737EU 1737
All tagsR407C 233R407F 172R404A 159R448A 136R407A 133R449A 122R507 115R134a 92R454C 82R455A 80R22 77R454A 77+8 more — search by name instead
SortNewestName A–ZSupplier A–Z

Showing 1441–1464 of 1737

Copeland ZPD83KCE-TF0 (R410A scroll, 50 Hz, AC)

R410A compressor — 20.3 kW cooling, 6.38 kW input, COP 3.18 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU, APAC

Copeland ZPD91KCE-TFD (R410A scroll, 50 Hz, AC)

R410A compressor — 21.6 kW cooling, 6.89 kW input, COP 3.14 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU, APAC

Copeland ZPDT18MCE-TF5 (R410A scroll, 50 Hz, AC)

R410A compressor — 43.1 kW cooling, 13.67 kW input, COP 3.15 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU, APAC

Copeland ZPDT31MCE-TFD (R410A scroll, 50 Hz, AC)

R410A compressor — 74.0 kW cooling, 23.24 kW input, COP 3.18 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU, APAC

Copeland ZPDU10M5E-TFD (R410A scroll, 50 Hz, AC)

R410A compressor — 25.1 kW cooling, 8.58 kW input, COP 2.92 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU, APAC

Copeland ZPDU22MCE-TFD (R410A scroll, 50 Hz, AC)

R410A compressor — 51.5 kW cooling, 16.15 kW input, COP 3.19 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU, APAC

Copeland ZPDU42MCE-TE5 (R410A scroll, 50 Hz, AC)

R410A compressor — 100.5 kW cooling, 31.07 kW input, COP 3.24 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU, APAC

Copeland ZPDU76K5E-TFD (R410A scroll, 50 Hz, AC)

R410A compressor — 19.1 kW cooling, 6.05 kW input, COP 3.15 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU, APAC

Copeland ZPI232KCE-TED (R410A scroll, 50 Hz, AC)

R410A compressor — 56.7 kW cooling, 16.96 kW input, COP 3.34 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU, APAC

Copeland ZPS104KCE-TFD (R410A scroll, 50 Hz, AC)

R410A compressor — 25.9 kW cooling, 7.93 kW input, COP 3.27 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU, APAC

Copeland ZPS122KCE-TFD (R410A scroll, 50 Hz, AC)

R410A compressor — 30.1 kW cooling, 9.31 kW input, COP 3.24 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU, APAC

Copeland ZPS26LXE-TFD (R410A scroll, 50 Hz, AC)

R410A compressor — 6.1 kW cooling, 2.16 kW input, COP 2.84 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU, APAC

Copeland ZPS27LXE-TF5 (R410A scroll, 50 Hz, AC)

R410A compressor — 6.2 kW cooling, 2.15 kW input, COP 2.88 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU, APAC

Copeland ZPS35LXE-TFD (R410A scroll, 50 Hz, AC)

R410A compressor — 8.8 kW cooling, 2.94 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU, APAC

Copeland ZPS38LXE-TF5 (R410A scroll, 50 Hz, AC)

R410A compressor — 6.2 kW cooling, 2.15 kW input, COP 2.88 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU, APAC

Copeland ZPS40LXE-TF5 (R410A scroll, 50 Hz, AC)

R410A compressor — 9.9 kW cooling, 3.22 kW input, COP 3.06 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU, APAC

Copeland ZPS67KCE-TFD (R410A scroll, 50 Hz, AC)

R410A compressor — 16.1 kW cooling, 5.40 kW input, COP 2.98 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU, APAC

Copeland ZPS76KCE-TFD (R410A scroll, 50 Hz, AC)

R410A compressor — 18.0 kW cooling, 6.12 kW input, COP 2.94 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU, APAC

Copeland ZPS83KCE-TFD (R410A scroll, 50 Hz, AC)

R410A compressor — 19.8 kW cooling, 6.64 kW input, COP 2.98 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU, APAC

Copeland ZPS91KCE-TFD (R410A scroll, 50 Hz, AC)

R410A compressor — 21.5 kW cooling, 6.82 kW input, COP 3.15 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU, APAC

Copeland ZPSU11MXE-TFD (R410A scroll, 50 Hz, AC)

R410A compressor — 27.3 kW cooling, 8.87 kW input, COP 3.08 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU, APAC

Copeland ZPSU58K5E-TFD (R410A scroll, 50 Hz, AC)

R410A compressor — 14.0 kW cooling, 4.83 kW input, COP 2.91 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU, APAC

Copeland ZPSU60K5E-TFD (R410A scroll, 50 Hz, AC)

R410A compressor — 14.7 kW cooling, 4.89 kW input, COP 3.00 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU, APAC

Copeland ZPSU69LXE-TFD (R410A scroll, 50 Hz, AC)

R410A compressor — 16.9 kW cooling, 5.79 kW input, COP 2.92 at the AHRI 7.2/54.4 °C rating point.

catalogR410A
Compressor · EU, APAC
‹ Previous1596061626373Next ›

How the model reads against Copeland's data

Compressor maps converted from the vendor's own rating database4 776 mapsevery basis median within 3.2 % of the nomenclature; the vendor's polynomial substituted exactly, never refitted

From the validation page; every row is held by a test.

Worked cases that run Copeland machines

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.

HVAC Builder · engineering results are estimates from catalog data and published correlations: ASHRAE, IAPWS-IF97, AHRI 540, EnergyPlus, CoolProp · weather data: PVGIS © European Union, JRC · contact: leads@hvacbuilder.app · bugs: bugs@hvacbuilder.app · validation · changelog · manufacturers · catalog · tools · Systems · Components · Suppliers · Privacy