Companies

Copeland Unclaimed

4776 listing(s) in HVAC Builder's catalog from Copeland's published data, selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; Copeland has not claimed it.

Compressor maps by refrigerant: R407C 636, R448A 508, R407F 443, R407A 435, R404A 343, R449A 332, R134a 239, R454C 232, R410A 230, R507 221, R455A 219, R454A 214, R513A 212, R22 182, R290 145, R454B 101, R450A 32, R1234yf 22, R32 16, R452A 14.

Are you Copeland?

Claim this page from the supplier portal: register as a supplier (company name and contact email), open the Company tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the supplier portal

Listings

All kindsCompressor 401
All marketsNA 401APAC 233EU 233
All tagsR407C 401R448A 371R407A 302R407F 271R449A 210R404A 184R454C 150R134a 145R513A 145R410A 141R455A 139R454A 137+8 more — search by name instead
SortNewestName A–ZSupplier A–Z

Showing 145–168 of 401

Copeland 6DVXF13ML-AWD (R407C Discus recip, 60 Hz, LD)

R407C compressor — 72.3 kW cooling, 104.61 kW input, COP 0.69 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Copeland 6DVXR49ME-TSE (R407C Discus recip, 60 Hz, MD)

R407C compressor — 150.1 kW cooling, 52.57 kW input, COP 2.86 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Copeland 6DVXR49ML-AWD (R407C Discus recip, 60 Hz, MD)

R407C compressor — 150.1 kW cooling, 52.57 kW input, COP 2.86 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Copeland 6DWNR32ME-TSK (R407C Discus recip, 60 Hz, AC)

R407C compressor — 68.6 kW cooling, 30.99 kW input, COP 2.21 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Copeland 6DWNR32ML-TSK (R407C Discus recip, 60 Hz, AC)

R407C compressor — 99.6 kW cooling, 30.99 kW input, COP 3.21 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Copeland 6DYNR32ME-TSK (R407C Discus recip, 60 Hz, AC)

R407C compressor — 99.6 kW cooling, 30.99 kW input, COP 3.21 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Copeland 6DYNR32ML-TSK (R407C Discus recip, 60 Hz, AC)

R407C compressor — 99.6 kW cooling, 30.99 kW input, COP 3.21 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Copeland 6DZNF13ME-TSE (R407C Discus recip, 60 Hz, LD)

R407C compressor — 72.3 kW cooling, 104.61 kW input, COP 0.69 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Copeland 6DZNR49ME-TSE (R407C Discus recip, 60 Hz, MD)

R407C compressor — 150.1 kW cooling, 52.57 kW input, COP 2.86 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Copeland 6DZNR49ML-AWD (R407C Discus recip, 60 Hz, MD)

R407C compressor — 150.1 kW cooling, 52.57 kW input, COP 2.86 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Copeland 6YBNR27ML-TSK (R407C Discus recip, 60 Hz, AC)

R407C compressor — 99.6 kW cooling, 30.99 kW input, COP 3.21 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Copeland 6YGNR35ME-TSN (R407C Discus recip, 60 Hz, AC)

R407C compressor — 119.8 kW cooling, 38.02 kW input, COP 3.15 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Copeland 6YGNR35ML-TSN (R407C Discus recip, 60 Hz, AC)

R407C compressor — 119.8 kW cooling, 38.02 kW input, COP 3.15 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Copeland 6YGXR35ME-TSN (R407C Discus recip, 60 Hz, AC)

R407C compressor — 119.8 kW cooling, 38.02 kW input, COP 3.15 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Copeland 6YHNR32ML-TSK (R407C Discus recip, 60 Hz, AC)

R407C compressor — 110.6 kW cooling, 34.20 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Copeland 6YJNR39ML-TSN (R407C Discus recip, 60 Hz, AC)

R407C compressor — 138.7 kW cooling, 42.88 kW input, COP 3.24 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Copeland 6YKNR32ME-TSK (R407C Discus recip, 60 Hz, AC)

R407C compressor — 110.6 kW cooling, 34.20 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Copeland 6YKNR32ML-TSK (R407C Discus recip, 60 Hz, AC)

R407C compressor — 110.6 kW cooling, 34.20 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Copeland 6YKXR32ME-TSK (R407C Discus recip, 60 Hz, AC)

R407C compressor — 110.6 kW cooling, 34.20 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Copeland 6YMNR35ME-TSN (R407C Discus recip, 60 Hz, AC)

R407C compressor — 119.8 kW cooling, 38.02 kW input, COP 3.15 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Copeland 6YMNR35ML-TSN (R407C Discus recip, 60 Hz, AC)

R407C compressor — 119.8 kW cooling, 38.02 kW input, COP 3.15 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Copeland 6YNNR35ME-FSD (R407C Discus recip, 60 Hz, AC)

R407C compressor — 119.8 kW cooling, 38.02 kW input, COP 3.15 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Copeland 6YRNR39ME-TSN (R407C Discus recip, 60 Hz, AC)

R407C compressor — 138.7 kW cooling, 42.88 kW input, COP 3.24 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA

Copeland 6YSNR39ME-TSN (R407C Discus recip, 60 Hz, AC)

R407C compressor — 138.7 kW cooling, 42.88 kW input, COP 3.24 at the AHRI 7.2/54.4 °C rating point.

catalogR407C
Compressor · NA
‹ Previous15678917Next ›

How the model reads against Copeland's data

Compressor maps converted from the vendor's own rating database4 776 mapsevery basis median within 3.2 % of the nomenclature; the vendor's polynomial substituted exactly, never refitted

From the validation page; every row is held by a test.

Worked cases that run Copeland machines

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.

HVAC Builder · engineering results are estimates from catalog data and published correlations: ASHRAE, IAPWS-IF97, AHRI 540, EnergyPlus, CoolProp · weather data: PVGIS © European Union, JRC · contact: leads@hvacbuilder.app · bugs: bugs@hvacbuilder.app · validation · changelog · manufacturers · catalog · tools · Systems · Components · Suppliers · Privacy