Companies

Drake Chillers Unclaimed

2 system(s) modelled in HVAC Builder on Drake Chillers' own published data. This page is listed by HVAC Builder from published data; Drake Chillers has not claimed it.

Are you Drake Chillers?

Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. We confirm each claim by hand before it takes effect; from then the page and its listings are yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page

Systems modelled on Drake Chillers' published data

Built in this model on the maker's own published data — not verified by Drake Chillers. Each page names the document it was read from and what the model was held to.

Drake PAC360D3 (30 HP air-cooled scroll chiller, R407C) — modelledDrake Chillers PAC360D data sheet (Pac360d-z+ref.pdf, Drake Refrigeration, Inc.) — the R407C performance table: tons and EER against leaving fluid from 35 to 65 °F and ambient from 80 to 105 °F, the two ZB114KCE named in the product information (docs/drake-chillers-source.json)
Drake PAC360D6 (30 HP air-cooled scroll chiller, R404A) — modelledDrake Chillers PAC360D data sheet (Pac360d-z+ref.pdf, Drake Refrigeration, Inc.) — the R404A performance table: tons and EER against leaving fluid from 0 to 55 °F and ambient from 80 to 105 °F, the two ZB114KCE named in the product information (docs/drake-chillers-source.json)

How the model reads against Drake Chillers' data

Drake Chillers PAC360D (30 HP, R407C and R404A), modelled — one air-cooled chiller on the catalog's maps of the compressor its sheet names, on both refrigerants it is sold on44 + the pinned cellthe pinned 45 °F row within −1.9 to +1.7 % on tons and −2.8 to 0 % on compressor power; every water row's ambient trend on both fluids, each cell against its row's 95 °F cell, at 1.2 % RMS on tons (worst 3.3) and 1.9 % on power (worst 4.7); and at 55 °F, the one leaving temperature both tables print, R404A's capacity over R407C's within −1.6 to −2.9 % of the sheet's ratio. Recorded, not held to the sheet: the sheet holds its evaporator at one approach whatever the duty ("selected upon requirements"), so one fixed conductance reads +6 to +11 % at 35 °F and −14 to −15 % at 65 °F; R404A's power over R407C's reads 4.9–8.7 % above the sheet's at 55 °F — the condenser model holds the refrigerant at its dew point, which credits R407C with half its 4.7 K glide, while the sheet's two tables are one condenser on the mean condensing temperature; the 0–25 °F R404A rows want glycol

From the validation page; every row is held by a test.

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.