Companies

Embraco Unclaimed

1283 listing(s) in HVAC Builder's catalog from Embraco's published data, selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; Embraco has not claimed it.

Compressor maps by refrigerant: R134a 518, R600a 315, R290 285, R404A 141, R22 11, R1234yf 10, R422D 2, R502 1.

Are you Embraco?

Claim this page from the supplier portal: register as a supplier (company name and contact email), open the Company tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the supplier portal

Listings

All kindsCompressor 285
All marketsAPAC 285CN 285EU 285LATAM 285NA 285
All tagsR134a 518R600a 315R290 285R404A 141R22 11R1234yf 10R422D 2R502 1
SortNewestName A–ZSupplier A–Z

Showing 49–72 of 285

Embraco EMC3121U (R290 hermetic, LBP, EN12900, 60 Hz)

R290 compressor — 0.8 kW cooling, 0.29 kW input, COP 2.69 at the AHRI 7.2/54.4 °C rating point.

catalogR290
Compressor · APAC, CN, EU, LATAM, NA

Embraco EMC3121U (R290 hermetic, MBP, EN12900, 50 Hz)

R290 compressor — 0.6 kW cooling, 0.23 kW input, COP 2.72 at the AHRI 7.2/54.4 °C rating point.

catalogR290
Compressor · APAC, CN, EU, LATAM, NA

Embraco EMC3121U (R290 hermetic, MBP, EN12900, 50-60 Hz)

R290 compressor — 0.8 kW cooling, 0.28 kW input, COP 2.79 at the AHRI 7.2/54.4 °C rating point.

catalogR290
Compressor · APAC, CN, EU, LATAM, NA

Embraco EMC3121U (R290 hermetic, MBP, EN12900, 60 Hz)

R290 compressor — 0.8 kW cooling, 0.29 kW input, COP 2.69 at the AHRI 7.2/54.4 °C rating point.

catalogR290
Compressor · APAC, CN, EU, LATAM, NA

Embraco EMC3125U (R290 hermetic, LBP, EN12900, 50 Hz)

R290 compressor — 0.8 kW cooling, 0.27 kW input, COP 2.89 at the AHRI 7.2/54.4 °C rating point.

catalogR290
Compressor · APAC, CN, EU, LATAM, NA

Embraco EMC3125U (R290 hermetic, LBP, EN12900, 50-60 Hz)

R290 compressor — 0.9 kW cooling, 0.34 kW input, COP 2.56 at the AHRI 7.2/54.4 °C rating point.

catalogR290
Compressor · APAC, CN, EU, LATAM, NA

Embraco EMC3125U (R290 hermetic, LBP, EN12900, 60 Hz)

R290 compressor — 0.9 kW cooling, 0.33 kW input, COP 2.61 at the AHRI 7.2/54.4 °C rating point.

catalogR290
Compressor · APAC, CN, EU, LATAM, NA

Embraco EMC3125U (R290 hermetic, MBP, EN12900, 50 Hz)

R290 compressor — 0.8 kW cooling, 0.27 kW input, COP 2.89 at the AHRI 7.2/54.4 °C rating point.

catalogR290
Compressor · APAC, CN, EU, LATAM, NA

Embraco EMC3125U (R290 hermetic, MBP, EN12900, 50-60 Hz)

R290 compressor — 0.9 kW cooling, 0.34 kW input, COP 2.56 at the AHRI 7.2/54.4 °C rating point.

catalogR290
Compressor · APAC, CN, EU, LATAM, NA

Embraco EMC3125U (R290 hermetic, MBP, EN12900, 60 Hz)

R290 compressor — 0.9 kW cooling, 0.33 kW input, COP 2.61 at the AHRI 7.2/54.4 °C rating point.

catalogR290
Compressor · APAC, CN, EU, LATAM, NA

Embraco EMC3130U (R290 hermetic, LBP, EN12900, 50 Hz)

R290 compressor — 0.8 kW cooling, 0.31 kW input, COP 2.71 at the AHRI 7.2/54.4 °C rating point.

catalogR290
Compressor · APAC, CN, EU, LATAM, NA

Embraco EMC3130U (R290 hermetic, LBP, EN12900, 60 Hz)

R290 compressor — 1.0 kW cooling, 0.41 kW input, COP 2.48 at the AHRI 7.2/54.4 °C rating point.

catalogR290
Compressor · APAC, CN, EU, LATAM, NA

Embraco EMC3130U (R290 hermetic, MBP, EN12900, 50 Hz)

R290 compressor — 0.8 kW cooling, 0.31 kW input, COP 2.71 at the AHRI 7.2/54.4 °C rating point.

catalogR290
Compressor · APAC, CN, EU, LATAM, NA

Embraco EMC3130U (R290 hermetic, MBP, EN12900, 60 Hz)

R290 compressor — 1.0 kW cooling, 0.41 kW input, COP 2.48 at the AHRI 7.2/54.4 °C rating point.

catalogR290
Compressor · APAC, CN, EU, LATAM, NA

Embraco EMC3134U (R290 hermetic, LBP, EN12900, 50 Hz)

R290 compressor — 1.0 kW cooling, 0.37 kW input, COP 2.78 at the AHRI 7.2/54.4 °C rating point.

catalogR290
Compressor · APAC, CN, EU, LATAM, NA

Embraco EMC3134U (R290 hermetic, LBP, EN12900, 50-60 Hz)

R290 compressor — 1.2 kW cooling, 0.45 kW input, COP 2.58 at the AHRI 7.2/54.4 °C rating point.

catalogR290
Compressor · APAC, CN, EU, LATAM, NA

Embraco EMC3134U (R290 hermetic, LBP, EN12900, 60 Hz)

R290 compressor — 1.5 kW cooling, 0.44 kW input, COP 3.43 at the AHRI 7.2/54.4 °C rating point.

catalogR290
Compressor · APAC, CN, EU, LATAM, NA

Embraco EMC3134U (R290 hermetic, MBP, EN12900, 50 Hz)

R290 compressor — 1.0 kW cooling, 0.37 kW input, COP 2.78 at the AHRI 7.2/54.4 °C rating point.

catalogR290
Compressor · APAC, CN, EU, LATAM, NA

Embraco EMC3134U (R290 hermetic, MBP, EN12900, 50-60 Hz)

R290 compressor — 1.2 kW cooling, 0.45 kW input, COP 2.58 at the AHRI 7.2/54.4 °C rating point.

catalogR290
Compressor · APAC, CN, EU, LATAM, NA

Embraco EMC3134U (R290 hermetic, MBP, EN12900, 60 Hz)

R290 compressor — 1.5 kW cooling, 0.44 kW input, COP 3.43 at the AHRI 7.2/54.4 °C rating point.

catalogR290
Compressor · APAC, CN, EU, LATAM, NA

Embraco EMC3140U (R290 hermetic, LBP, EN12900, 50 Hz)

R290 compressor — 1.1 kW cooling, 0.45 kW input, COP 2.50 at the AHRI 7.2/54.4 °C rating point.

catalogR290
Compressor · APAC, CN, EU, LATAM, NA

Embraco EMC3140U (R290 hermetic, LBP, EN12900, 60 Hz)

R290 compressor — 1.4 kW cooling, 0.55 kW input, COP 2.50 at the AHRI 7.2/54.4 °C rating point.

catalogR290
Compressor · APAC, CN, EU, LATAM, NA

Embraco EMC3140U (R290 hermetic, MBP, EN12900, 50 Hz)

R290 compressor — 1.1 kW cooling, 0.45 kW input, COP 2.50 at the AHRI 7.2/54.4 °C rating point.

catalogR290
Compressor · APAC, CN, EU, LATAM, NA

Embraco EMC3140U (R290 hermetic, MBP, EN12900, 60 Hz)

R290 compressor — 1.4 kW cooling, 0.55 kW input, COP 2.50 at the AHRI 7.2/54.4 °C rating point.

catalogR290
Compressor · APAC, CN, EU, LATAM, NA
‹ Previous1234512Next ›

How the model reads against Embraco's data

Embraco hermetic and variable-capacity compressor maps, fitted from the maker's published tables1 283 maps from 815 models (R134a 518, R600a 315, R290 285, R404A 141, R22 11, R1234yf 10, R422D 2, R502 1); 178 variable-capacity models with a table per speedfitted at the order each table's levels determine (three condensing levels: quadratic in tc), the tables are reproduced at a median RMS of 0.08 % (p90 0.20 %); every map reads the standard's own rating point within 0.08 % at the median and 0.4 % at the ninetieth percentile; every carried flow set closes the identity once the rating's own return-gas and liquid temperatures are read off the node (ASHRAE rates with the liquid at 32.2 °C, 22 K under the condenser). 72 tables withheld and listed by reason: blend groups published as one table, variable-capacity models with fewer than three speeds tabulated, three with a COP under 0.5 at the rating point, three duplicates

From the validation page; every row is held by a test.

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.

HVAC Builder · engineering results are estimates from catalog data and published correlations: ASHRAE, IAPWS-IF97, AHRI 540, EnergyPlus, CoolProp · weather data: PVGIS © European Union, JRC · contact: leads@hvacbuilder.app · bugs: bugs@hvacbuilder.app · validation · changelog · manufacturers · catalog · tools · Systems · Components · Suppliers · Privacy