Companies

Embraco Unclaimed

1,283 listings in HVAC Builder's catalog from Embraco's published data, selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; Embraco has not claimed it.

Compressor maps by refrigerant: R134a 518, R600a 315, R290 285, R404A 141, R22 11, R1234yf 10, R422D 2, R502 1.

Embraco compressor ranges

Each range on a page of its own: every model code with its refrigerants, frequencies and ratings, and every model a page.

Are you Embraco?

Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. We confirm each claim by hand before it takes effect; from then the page and its listings are yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page

Components

Showing 1–24 of 1,283

NameTypeRatingMarketsOpen in the builder
Embraco EG100HLR (R134a hermetic, LBP, ASHRAE, 50 Hz) CatalogCompressorsR134a compressor — 0.19 kW cooling, 0.14 kW input, COP 1.32 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Embraco EGAS100CLP (R600a hermetic, LBP, EN12900, 50-60 Hz) CatalogCompressorsR600a compressor — 0.20 kW cooling, 0.15 kW input, COP 1.35 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Embraco EGD60HLC (R134a hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsR134a compressor — 0.13 kW cooling, 0.08 kW input, COP 1.60 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Embraco EGM80CLC (R600a hermetic, LBP, ASHRAE, 50 Hz) CatalogCompressorsR600a compressor — 0.15 kW cooling, 0.09 kW input, COP 1.66 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Embraco EGU110HLC (R134a hermetic, LBP, ASHRAE, 50-60 Hz) CatalogCompressorsR134a compressor — 0.25 kW cooling, 0.16 kW input, COP 1.60 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Embraco EGUS100HLP (R134a hermetic, LBP, ASHRAE, 50-60 Hz) CatalogCompressorsR134a compressor — 0.23 kW cooling, 0.14 kW input, COP 1.63 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Embraco EGX100CLC (R600a hermetic, LBP, ASHRAE, 50 Hz) CatalogCompressorsR600a compressor — 0.16 kW cooling, 0.09 kW input, COP 1.78 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Embraco EGYS100HLP (R134a hermetic, LBP, ASHRAE, 50 Hz) CatalogCompressorsR134a compressor — 0.19 kW cooling, 0.11 kW input, COP 1.64 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Embraco EGZ70HLP (R134a hermetic, LBP, EN12900, 60 Hz) CatalogCompressorsR134a compressor — 0.15 kW cooling, 0.10 kW input, COP 1.55 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Embraco EGZS100HLC (R134a hermetic, LBP, EN12900, 50-60 Hz) CatalogCompressorsR134a compressor — 0.21 kW cooling, 0.14 kW input, COP 1.58 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Embraco EHU2140GK (R404A hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsR404A compressor — 0.27 kW cooling, 0.24 kW input, COP 1.12 at -35/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Embraco EHX2155U (R290 hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsR290 compressor — 0.36 kW cooling, 0.26 kW input, COP 1.37 at -35/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Embraco EM20HBR (R134a hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsR134a compressor — 0.20 kW cooling, 0.10 kW input, COP 1.97 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Embraco EMB32CLC (R600a hermetic, LBP, ASHRAE, 50 Hz) CatalogCompressorsR600a compressor — 0.08 kW cooling, 0.04 kW input, COP 1.90 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Embraco EMC20CLT (R600a hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsR600a compressor — 0.05 kW cooling, 0.03 kW input, COP 1.42 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Embraco EMD20CLT (R600a hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsR600a compressor — 0.05 kW cooling, 0.03 kW input, COP 1.62 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Embraco EMDS55CLC (R600a hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsR600a compressor — 0.14 kW cooling, 0.08 kW input, COP 1.70 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Embraco EME20CLT (R600a hermetic, LBP, EN12900, 50 Hz) CatalogCompressorsR600a compressor — 0.05 kW cooling, 0.03 kW input, COP 1.80 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Embraco EMH60HER (R134a hermetic, LBP, ASHRAE, 60 Hz) CatalogCompressorsR134a compressor — 0.14 kW cooling, 0.10 kW input, COP 1.41 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Embraco EMI28HER (R134a hermetic, LBP, ASHRAE, 50-60 Hz) CatalogCompressorsR134a compressor — 0.07 kW cooling, 0.06 kW input, COP 1.11 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Embraco EMIE30HER (R134a hermetic, LBP, ASHRAE, 50-60 Hz) CatalogCompressorsR134a compressor — 0.07 kW cooling, 0.05 kW input, COP 1.25 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Embraco EMIS10HLR (R134a hermetic, LBP, ASHRAE, 60 Hz) CatalogCompressorsR134a compressor — 0.03 kW cooling, 0.05 kW input, COP 0.52 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Embraco EMM32CLC (R600a hermetic, LBP, ASHRAE, 50 Hz) CatalogCompressorsR600a compressor — 0.08 kW cooling, 0.04 kW input, COP 1.90 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Embraco EMR100HLC (R134a hermetic, LBP, EN12900, 50-60 Hz) CatalogCompressorsR134a compressor — 0.19 kW cooling, 0.14 kW input, COP 1.43 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
123…54Next ›

How the model reads against Embraco's data

Embraco hermetic and variable-capacity compressor maps, fitted from the maker's published tables1 283 maps from 815 models (R134a 518, R600a 315, R290 285, R404A 141, R22 11, R1234yf 10, R422D 2, R502 1); 178 variable-capacity models with a table per speedfitted at the order each table's levels determine (three condensing levels: quadratic in tc), the tables are reproduced at a median RMS of 0.08 % (p90 0.20 %); every map reads the standard's own rating point within 0.08 % at the median and 0.4 % at the ninetieth percentile; every carried flow set closes the identity once the rating's own return-gas and liquid temperatures are read off the node (ASHRAE rates with the liquid at 32.2 °C, 22 K under the condenser). 72 tables withheld and listed by reason: blend groups published as one table, variable-capacity models with fewer than three speeds tabulated, three with a COP under 0.5 at the rating point, three duplicates

From the validation page; every row is held by a test.

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.