43 Embraco EMI compressor maps from the maker's published data — 23 model codes on R134a (25), R290 (10), R600a (8). Every model is a page of its own with its AHRI 540 / EN 12900 map sampled across the published envelope, and every one is selectable in the builder, which solves it with the catalog's own figures.

Model codeListingRefrigerantEvaporating range °CkW at 7.2 / 54.4 °C
EMI28HEREmbraco EMI28HER (R134a hermetic, LBP, ASHRAE, 50-60 Hz)R134a-35 … -10
Embraco EMI28HER (R134a hermetic, LBP, ASHRAE, 60 Hz)R134a-35 … -10
EMI30CEPEmbraco EMI30CEP (R600a hermetic, LBP, ASHRAE, 50 Hz)R600a-35 … -10
EMI30CNPEmbraco EMI30CNP (R600a hermetic, LBP, ASHRAE, 50-60 Hz)R600a-35 … -5
Embraco EMI30CNP (R600a hermetic, MBP, EN12900, 50-60 Hz)R600a-35 … -5
EMI30HEREmbraco EMI30HER (R134a hermetic, LBP, ASHRAE, 50-60 Hz)R134a-35 … -10
Embraco EMI30HER (R134a hermetic, LBP, ASHRAE, 60 Hz)R134a-35 … -10
Embraco EMI30HER (R134a hermetic, MBP, EN12900, 60 Hz)R134a-35 … -5
EMI30HEXEmbraco EMI30HEX (R134a hermetic, LBP, ASHRAE, 60 Hz)R134a-35 … -5
Embraco EMI30HEX (R134a hermetic, MBP, EN12900, 60 Hz)R134a-35 … -5
EMI32CLPEmbraco EMI32CLP (R600a hermetic, LBP, EN12900, 50 Hz)R600a-35 … -10
EMI40CNCEmbraco EMI40CNC (R600a hermetic, LBP, ASHRAE, 60 Hz)R600a-35 … -10
Embraco EMI40CNC (R600a hermetic, LBP, EN12900, 50-60 Hz)R600a-35 … -10
EMI40CNPEmbraco EMI40CNP (R600a hermetic, LBP, ASHRAE, 50-60 Hz)R600a-35 … -5
Embraco EMI40CNP (R600a hermetic, MBP, EN12900, 50-60 Hz)R600a-35 … -5
EMI40HNPEmbraco EMI40HNP (R134a hermetic, LBP, ASHRAE, 60 Hz)R134a-35 … -10
EMI40HNREmbraco EMI40HNR (R134a hermetic, LBP, ASHRAE, 60 Hz)R134a-35 … -10
EMI45HEPEmbraco EMI45HEP (R134a hermetic, LBP, EN12900, 50 Hz)R134a-35 … -10
EMI45HEREmbraco EMI45HER (R134a hermetic, LBP, ASHRAE, 50-60 Hz)R134a-35 … -10
Embraco EMI45HER (R134a hermetic, LBP, ASHRAE, 60 Hz)R134a-35 … -10
EMI50HEREmbraco EMI50HER (R134a hermetic, LBP, ASHRAE, 50-60 Hz)R134a-35 … -10
Embraco EMI50HER (R134a hermetic, LBP, ASHRAE, 60 Hz)R134a-35 … -10
EMI50UEREmbraco EMI50UER (R290 hermetic, LBP, EN12900, 50-60 Hz)R290-35 … -5
Embraco EMI50UER (R290 hermetic, LBP, EN12900, 60 Hz)R290-35 … -5
Embraco EMI50UER (R290 hermetic, MBP, EN12900, 50-60 Hz)R290-35 … -5
Embraco EMI50UER (R290 hermetic, MBP, EN12900, 60 Hz)R290-35 … -5
EMI55HEREmbraco EMI55HER (R134a hermetic, LBP, ASHRAE, 50-60 Hz)R134a-35 … -10
Embraco EMI55HER (R134a hermetic, LBP, ASHRAE, 60 Hz)R134a-35 … -10
EMI60HEPEmbraco EMI60HEP (R134a hermetic, LBP, ASHRAE, 50-60 Hz)R134a-35 … -10
EMI60HEREmbraco EMI60HER (R134a hermetic, LBP, ASHRAE, 50-60 Hz)R134a-35 … -10
Embraco EMI60HER (R134a hermetic, LBP, ASHRAE, 60 Hz)R134a-35 … -10
EMI60HSREmbraco EMI60HSR (R134a hermetic, LBP, ASHRAE, 60 Hz)R134a-35 … -15
EMI70HDREmbraco EMI70HDR (R134a hermetic, HBP, EN12900, 60 Hz)R134a-5 … 150.7
EMI70HEREmbraco EMI70HER (R134a hermetic, LBP, ASHRAE, 50 Hz)R134a-35 … -10
Embraco EMI70HER (R134a hermetic, LBP, ASHRAE, 60 Hz)R134a-35 … -10
EMI70HNREmbraco EMI70HNR (R134a hermetic, LBP, ASHRAE, 60 Hz)R134a-35 … -5
Embraco EMI70HNR (R134a hermetic, MBP, EN12900, 60 Hz)R134a-35 … -5
EMI70UEREmbraco EMI70UER (R290 hermetic, LBP, EN12900, 50-60 Hz)R290-35 … -5
Embraco EMI70UER (R290 hermetic, LBP, EN12900, 60 Hz)R290-35 … -5
Embraco EMI70UER (R290 hermetic, MBP, EN12900, 50-60 Hz)R290-35 … -5
Embraco EMI70UER (R290 hermetic, MBP, EN12900, 60 Hz)R290-35 … -5
EMI90UEXEmbraco EMI90UEX (R290 hermetic, LBP, EN12900, 60 Hz)R290-35 … -5
Embraco EMI90UEX (R290 hermetic, MBP, EN12900, 60 Hz)R290-35 … -5

The rating is the map read at the AHRI 540 air-conditioning point; a dash means the point lies outside the machine's own envelope (a refrigeration compressor is not rated there). The evaporating range is the published envelope's.

Open the builder and pick any of them from the catalog picker, or read one at your own conditions in the compressor-map lookup.

Other Embraco ranges: EM (152) · NT (78) · NEK (77) · EMT (76) · EMY (65) · EMX (63) · NEU (62) · EMC (42) · EMU (32) · FFU (32) · FFI (29) · NJ (28) · FMFT (24) · FF (20) · EGAS (19) · EMR (18) · every Embraco listing.

HVAC Builder · engineering results are estimates from catalog data and published correlations: ASHRAE, IAPWS-IF97, AHRI 540, EnergyPlus, CoolProp · weather data: PVGIS © European Union, JRC · contact: leads@hvacbuilder.app · bugs: bugs@hvacbuilder.app · validation · changelog · manufacturers · catalog · refrigerants · tools · Systems · Components · Suppliers · Privacy