992 listing(s) in HVAC Builder's catalog from EVAPCO's published data and 992 system(s) modelled on it — 0 built by hand and 992 derived from the listings themselves — selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; EVAPCO has not claimed it.

Are you EVAPCO?

Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page

Listings

All kindsCooling tower 992
Any certificationCTI STD-201 (validation C13A-99R28) 822
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 1–24 of 992

EVAPCO AT 110-2I12 cooling tower

Cooling tower — 995 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 30.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-2I18 cooling tower

Cooling tower — 1271 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 40.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-2J12 cooling tower

Cooling tower — 1209 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 34.7 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-2J18 cooling tower

Cooling tower — 1538 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 46.2 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-2K12 cooling tower

Cooling tower — 1336 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 38.0 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-2K18 cooling tower

Cooling tower — 1704 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 50.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-2L12 cooling tower

Cooling tower — 1428 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 40.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-2L18 cooling tower

Cooling tower — 1840 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 54.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-2M12 cooling tower

Cooling tower — 1498 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 43.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-2M18 cooling tower

Cooling tower — 1950 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 57.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-3I12 cooling tower

Cooling tower — 1157 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 30.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-3I18 cooling tower

Cooling tower — 1459 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 40.0 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-3J12 cooling tower

Cooling tower — 1354 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 34.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-3J18 cooling tower

Cooling tower — 1731 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 45.4 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-3K12 cooling tower

Cooling tower — 1481 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 37.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-3K18 cooling tower

Cooling tower — 1915 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 49.8 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-3L12 cooling tower

Cooling tower — 1582 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 40.1 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-3L18 cooling tower

Cooling tower — 2064 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 53.4 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-3M12 cooling tower

Cooling tower — 1665 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 42.4 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-3M18 cooling tower

Cooling tower — 2186 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 56.5 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-3N18 cooling tower

Cooling tower — 2397 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 61.9 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-4I12 cooling tower

Cooling tower — 1214 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 29.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-4I18 cooling tower

Cooling tower — 1595 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 39.3 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower

EVAPCO AT 110-4J12 cooling tower

Cooling tower — 1411 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 33.6 m³/s of air.

catalogCTI STD-201 (validation C13A-99R28) ✓
Cooling tower
123…42Next ›

How the model reads against EVAPCO's data

Cooling-tower model, zero fitted parameters856mean −0.03 K, RMS 0.064 K, worst 0.24 K — NTU from the vendor's own Eurovent column, the shipped default exponent (−0.7, the joint minimum with Marley's table)
Cooling-tower model against a fourth maker's whole open-tower range, nothing fitted to it45 945 over 992 machinesmean −0.083 K, RMS 0.220 K, worst 1.89 K on leaving water. 0.098 K at the 78 °F rating wet bulb, where the NTU is derived, rising to 0.283 and 0.288 K at 50 and 90 °F. The fill's loading exponent was swept on either half of the range and the shipped default (−0.7, the joint minimum of EVAPCO's own LPT bulletin and Marley's table) is the minimum for this range too, so it carries no constant of its own — unlike BAC's five, which wanted −0.9 to −1.3

From the validation page; every row is held by a test.

Worked cases that run EVAPCO machines

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.