1 system(s) modelled in HVAC Builder on Gree's published performance data and validated against it. This page is listed by HVAC Builder from published data; Gree has not claimed it.

Are you Gree?

Claim this page from the supplier portal: register as a supplier (company name and contact email), open the Company tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the supplier portal

Systems modelled on Gree's published data

Built in this model on the maker's published performance grid and validated against it — not verified by Gree. Each page names its source and says so.

Gree GMV5 GMV-168WM/B (14 ton, 49 kW) — modelledGree GMV5 DC-inverter VRF units technical sales guide (460 V heat pump) — GMV-168WM/B cooling capacity table, 100 % combination at 66.2 °F WB / 80.6 °F DB indoor, total capacity and power input against outdoor dry bulb (docs/gree-vrf-source.json)

How the model reads against Gree's data

Heat-pump frost/defrost derate43, from five makersRMS 0.023, where the makers stand 0.029 from each other at the forty temperatures they share — the one generic curve is closer to each of them than they are to one another, and none is served much worse than any other (0.019–0.028 apiece). The EnergyPlus model this replaced had the shape inverted (deepest just below its 5 °C cutoff, then a 29-point step across it) and read up to 0.15 low
VRF (multi-split): capacity against the connected-capacity ratioeight makersthey agree on a two-regime law — exactly linear below 100 % connection, saturating above it by +2 to +8 % at 130 %, with Samsung allowing no credit above 130 % — and the model reproduces both without a correction term: below full connection each indoor coil caps its own take, above it the outdoor unit's map is the ceiling (+0 %, the conservative end of the band). The standards themselves rate only at unity connection (±5 %)
Gree GMV5 GMV-168WM/B (14 ton), modelled — the validated machine scaled to another frame, against Gree's published grid8every dimension of the 20 HP graph scaled by 49.2/56 at once and modulated to Gree's capacity, the machine draws −4 to +1 % of Gree's power input — nothing re-fitted

From the validation page; every row is held by a test.

Worked cases that run Gree machines

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.

HVAC Builder · engineering results are estimates from catalog data and published correlations: ASHRAE, IAPWS-IF97, AHRI 540, EnergyPlus, CoolProp · weather data: PVGIS © European Union, JRC · contact: leads@hvacbuilder.app · bugs: bugs@hvacbuilder.app · validation · changelog · manufacturers · catalog · tools · Systems · Components · Suppliers · Privacy