Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. We confirm each claim by hand before it takes effect; from then the page and its listings are yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page
Listings
Showing 1–1 of 1
U.S. Boiler Baseray 9A cast-iron baseboard, per foot of active length (1 gpm)
Hydronic emitter rated per foot of active length: 0.122 kW at an excess of 63.9 K, exponent 1.238.
How the model reads against U.S. Boiler's data
| A hydronic baseboard rated per foot, against its maker's own table: the emitter's power law read from one printed column, the figure ÷ 1.15 and over 65 °F entering air, carried to every other water temperature by an exponent fitted on the printed columns | 18 water cells and the steam rating; 1 listing | listed at the 180 °F, 1 gpm column — 480 Btu/h a foot ÷ 1.15, 0.122 kW over 0.3048 m at 63.9 K — with n 1.238, the least-squares fit of all nine 1 gpm columns as printed against 65 °F (largest deviation of the fit 1.7 %), the model reads every 1 gpm cell within 3.2 % (+3.17 % at 150 °F: the listing holds the 180 °F cell as printed, 480, where the fit's line reads 473), on a run of one foot and of ten. The fit is the printed table's, not a measurement's: the sheet does not say which columns were tested, and from 170 °F up its 1 gpm row is a straight line, 5 Btu/h a foot per °F, which no power law draws. That fit stands over the model's default exponent (the owner's call of 10 Oct 2026, recorded with the data): at 1.3 the model would read the 1 gpm cells −0.8 to +5.1 %; which columns were tested is a question for U.S. Boiler. The model has no flow term, so it reads every 4 gpm cell 2.5 to 5.9 % under — the uplift the sheet prints and the model leaves out. In a room: the rating is over 65 °F entering air and the model reads Δt over the air entering the part, the room's in a building, so a 68–70 °F room reads 3.2–5.4 % under the tested rating at 180 °F average water and 4.9–8.2 % at 140 °F, which the listing's page states. Not modelled: the steam rating (860 Btu/h at 215 °F), which the sheet's own 3.40 sq ft of EDR does not give (816) |
From the validation page; every row is held by a test.