Catalog · Ziehl-Abegg

Ziehl-Abegg FE3owlet FG080-ADI.6N.V5L1 art. 182467 (axial Ø800, AC 3~ 400/460 V, with guard grille)

Fan — Fan rated 2.29 m³/s at 0.47 kW.

A Ziehl-Abegg listing, from the manufacturer's published data.

Units: SI · US customary

Published specification

Design air flow2.29 m³/s
Shaft power0.47 kW
External static72 Pa

Manufacturer's product page

Open this part in the app — as a component of its own, carrying the catalog's figures; or open the builder and pick it from the catalog picker. The solver runs it with the catalog's own data, at your design point or across a year of weather.

Same family

fansZiehl-Abegg FE3owlet FG080-SDA.6N.V5P1 art. 180393 (axial Ø800, AC 3~ 400/460 V, without guard grille)
fansZiehl-Abegg FE3owlet FG080-SDS.6N.V5P1 art. 180394 (axial Ø800, AC 3~ 400/460 V, with guard grille)
fansZiehl-Abegg FE3owlet FG080-SDQ.6N.V5P1 art. 180395 (axial Ø800, AC 3~ 400/460 V, square full bell mouth)
fansZiehl-Abegg FE3owlet FG080-SDK.6N.V5P1 art. 180396 (axial Ø800, AC 3~ 400/460 V, with guard grille)
fansZiehl-Abegg FE3owlet FG080-SDI.6N.V5P1 art. 180397 (axial Ø800, AC 3~ 400/460 V, with guard grille)
fansZiehl-Abegg FE3owlet FG080-SDF.6N.V5P1 art. 180398 (axial Ø800, AC 3~ 400/460 V, without guard grille)
fansZiehl-Abegg FE3owlet FG080-SDA.6N.A5P1 art. 180415 (axial Ø800, AC 3~ 400/460 V, without guard grille)
fansZiehl-Abegg FE3owlet FG080-SDQ.6N.A5P1 art. 180416 (axial Ø800, AC 3~ 400/460 V, square full bell mouth)
fansZiehl-Abegg FE3owlet FG080-SDA.6N.V5N1 art. 182451 (axial Ø800, AC 3~ 400/460 V, without guard grille)
fansZiehl-Abegg FE3owlet FG080-SDS.6N.V5N1 art. 182452 (axial Ø800, AC 3~ 400/460 V, with guard grille)
fansZiehl-Abegg FE3owlet FG080-SDQ.6N.V5N1 art. 182453 (axial Ø800, AC 3~ 400/460 V, square full bell mouth)
fansZiehl-Abegg FE3owlet FG080-SDK.6N.V5N1 art. 182454 (axial Ø800, AC 3~ 400/460 V, with guard grille)

How the model reads against this maker's data

Ziehl-Abegg FE2owlet axial fans read from their own product pages30 listings (Ø250–910, ECblue and AC); 4 with curvesevery listing's design point and nameplate power are the page's printed optimum; a curve is listed only where the article's own printed maxima and optimum sit on the chart — the FN025 and FN030 4IA articles do, within 0.1 / 0.8 / 1.2 % (head, foot, optimum) — and its power curve peaks within 1.5 % of the duty table's curve-I figure; the solver reads the printed P1 back at the design point within 1 %

From the validation page; every row is held by a test.

Listed from published data; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.