Cambridge Air Solutions Unclaimed
13 listings in HVAC Builder's catalog from Cambridge Air Solutions' published data, selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; Cambridge Air Solutions has not claimed it.
- Heaters — 13
Are you Cambridge Air Solutions?
Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. We confirm each claim by hand before it takes effect; from then the page and its listings are yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page
Components
Showing 1–13 of 13
How the model reads against Cambridge Air Solutions' data
| Direct gas-fired heaters against their maker's own capacity table: the heater model's sensible duty to a discharge target, its gas at the listing's efficiency, and the burner's combustion water in the supply | 43 printed cells; 13 listings | the manual's formula gives every cell within 0.14 % (the worst, the S800's 757 MBH at 3 500 cfm, is its airflow printed round). Listed at 0.92 of each row's input — the sensible output by the manual's own split — and its inlet airflow as printed (the table states its airflow at the blower's inlet density, which is how the model reads a heater's), the model discharges within 0.4 °F of 160 °F, each cell at its own inlet and airflow. And it carries the burner's water (since 10 Oct 2026): a direct-fired burner fires into the air it heats, and methane makes 0.146 kg of water per kWh of gross input, whose latent heat is 9.9 % of it. So the listings carry that water and an efficiency of 0.901 — the most of its input a methane burner can put into sensible heat, where the manual converts at the 92 % Cambridge certifies — and the supply's moisture is the burner's: 4.0 g/kg added at the 160 °F rating and 3.5 at 140 °F — on saturated 0 °F air a supply at a 3.7 °C dew point, where the model without the water read −17.8 °C. The price is gas: the model burns 2.1 to 2.3 % more than every printed cell, and on the nine listings rated at their burner's maximum — the S400 1 HP, the S950 2 and 3 HP, the S1200 3 and 5 HP, the S1850 5 and 7½ HP and the S2200 7½ and 10 HP, 20 of the 43 cells — that is 2.1 % past the maximum the gas-pressure table prints (408 MBH on the S400's 400 MBH burner) |
From the validation page; every row is held by a test.
Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.