Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. We confirm each claim by hand before it takes effect; from then the page and its listings are yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page
Listings
Showing 1–13 of 13
Cambridge Air Solutions S1200 direct gas-fired space heater, 3 HP (1,200 MBH input at a 160 °F rise)
Air heater, 323.6 kW at 2.62 m³/s.
Cambridge Air Solutions S1200 direct gas-fired space heater, 5 HP (1,200 MBH input at a 140 °F rise)
Air heater, 323.6 kW at 3.13 m³/s.
Cambridge Air Solutions S1600 direct gas-fired space heater, 5 HP (1,499 MBH input at a 160 °F rise)
Air heater, 404.2 kW at 3.28 m³/s.
Cambridge Air Solutions S1850 direct gas-fired space heater, 5 HP (1,850 MBH input at a 160 °F rise)
Air heater, 498.8 kW at 4.04 m³/s.
Cambridge Air Solutions S1850 direct gas-fired space heater, 7½ HP (1,850 MBH input at a 140 °F rise)
Air heater, 498.8 kW at 4.82 m³/s.
Cambridge Air Solutions S2200 direct gas-fired space heater, 10 HP (2,200 MBH input at a 140 °F rise)
Air heater, 593.2 kW at 5.73 m³/s.
Cambridge Air Solutions S2200 direct gas-fired space heater, 7½ HP (2,200 MBH input at a 160 °F rise)
Air heater, 593.2 kW at 4.81 m³/s.
Cambridge Air Solutions S3200 direct gas-fired space heater, 10 HP (2,718 MBH input at a 160 °F rise)
Air heater, 732.8 kW at 5.94 m³/s.
Cambridge Air Solutions S3200 direct gas-fired space heater, 15 HP (3,107 MBH input at a 160 °F rise)
Air heater, 837.7 kW at 6.79 m³/s.
Cambridge Air Solutions S400 direct gas-fired space heater, 1 HP (400 MBH input at a 160 °F rise)
Air heater, 107.8 kW at 0.87 m³/s.
Cambridge Air Solutions S800 direct gas-fired space heater, 3 HP (757 MBH input at a 160 °F rise)
Air heater, 204.1 kW at 1.65 m³/s.
Cambridge Air Solutions S950 direct gas-fired space heater, 2 HP (950 MBH input at a 160 °F rise)
Air heater, 256.1 kW at 2.08 m³/s.
Cambridge Air Solutions S950 direct gas-fired space heater, 3 HP (950 MBH input at a 140 °F rise, with filter section)
Air heater, 256.1 kW at 2.48 m³/s.
How the model reads against Cambridge Air Solutions' data
| Direct gas-fired heaters against their maker's own capacity table: the heater model's sensible duty to a discharge target, its gas at the listing's efficiency | 43 printed cells; 13 listings | the manual's formula gives every cell within 0.14 % (the worst, the S800's 757 MBH at 3 500 cfm, is its airflow printed round). Listed at 0.92 of each row's input and its inlet airflow as printed — the table states its airflow at the blower's inlet density, which is how the model reads a heater's — the model burns every printed input within +0.18 % and discharges within 0.4 °F of 160 °F, each cell at its own inlet and airflow. What the model leaves out: a direct-fired burner puts its combustion water into the air it heats — 0.146 kg per kWh of gas from methane's stoichiometry, 3.9 g/kg on the supply at the 160 °F rating, four times what 0 °F air can hold — and the model carries none of it, so the supply's temperature, heat and gas are the table's and its moisture is the outdoor air's: a 3.5 °C dew point reads as −17.8 °C |