Catalog · Cambridge Air Solutions

Cambridge Air Solutions S1200 direct gas-fired space heater, 5 HP (1,200 MBH input at a 140 °F rise)

Heater — Air heater, 323.6 kW at 3.13 m³/s.

A Cambridge Air Solutions listing, from the manufacturer's published data.

Units: SI · US customary

Published specification

Capacity323.6 kW
Design air flow3.13 m³/s
Efficiency (the model's)0.901 kW heat per kW of gas (gross) — what the latent heat of its water leaves. The manual gives 0.92, its conversion from sensible to total heat, so the model burns 2.1 % more gas than the input the manual prints
Combustion water (the model's)0.146 kg/kWh of gas (gross), into the air it heats (a direct-fired burner)

Manufacturer's product page

Open this part in the app — as a component of its own, carrying the catalog's figures; or open the builder and pick it from the catalog picker. The solver runs it with the catalog's own data, at your design point or across a year of weather.

Same family

HeaterCambridge Air Solutions S1200 direct gas-fired space heater, 3 HP (1,200 MBH input at a 160 °F rise)

How the model reads against this maker's data

Direct gas-fired heaters against their maker's own capacity table: the heater model's sensible duty to a discharge target, its gas at the listing's efficiency, and the burner's combustion water in the supply43 printed cells; 13 listingsthe manual's formula gives every cell within 0.14 % (the worst, the S800's 757 MBH at 3 500 cfm, is its airflow printed round). Listed at 0.92 of each row's input — the sensible output by the manual's own split — and its inlet airflow as printed (the table states its airflow at the blower's inlet density, which is how the model reads a heater's), the model discharges within 0.4 °F of 160 °F, each cell at its own inlet and airflow. And it carries the burner's water (since 10 Oct 2026): a direct-fired burner fires into the air it heats, and methane makes 0.146 kg of water per kWh of gross input, whose latent heat is 9.9 % of it. So the listings carry that water and an efficiency of 0.901 — the most of its input a methane burner can put into sensible heat, where the manual converts at the 92 % Cambridge certifies — and the supply's moisture is the burner's: 4.0 g/kg added at the 160 °F rating and 3.5 at 140 °F — on saturated 0 °F air a supply at a 3.7 °C dew point, where the model without the water read −17.8 °C. The price is gas: the model burns 2.1 to 2.3 % more than every printed cell, and on the nine listings rated at their burner's maximum — the S400 1 HP, the S950 2 and 3 HP, the S1200 3 and 5 HP, the S1850 5 and 7½ HP and the S2200 7½ and 10 HP, 20 of the 43 cells — that is 2.1 % past the maximum the gas-pressure table prints (408 MBH on the S400's 400 MBH burner)

From the validation page; every row is held by a test.

Listed from published data; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.