Companies

Copeland Unclaimed

4776 listing(s) in HVAC Builder's catalog from Copeland's published data, selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; Copeland has not claimed it.

Compressor maps by refrigerant: R407C 636, R448A 508, R407F 443, R407A 435, R404A 343, R449A 332, R134a 239, R454C 232, R410A 230, R507 221, R455A 219, R454A 214, R513A 212, R22 182, R290 145, R454B 101, R450A 32, R1234yf 22, R32 16, R452A 14.

Are you Copeland?

Claim this page from the supplier portal: register as a supplier (company name and contact email), open the Company tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the supplier portal

Listings

All kindsCompressor 77
All marketsNA 105APAC 77EU 77
All tagsR407C 233R407F 172R404A 159R448A 136R407A 133R449A 122R507 115R134a 92R454C 82R455A 80R22 77R454A 77+8 more — search by name instead
SortNewestName A–ZSupplier A–Z

Showing 1–24 of 77

Copeland 6DUNR49ME-TSE (R22 Discus recip, 50 Hz, MD)

R22 compressor — 125.8 kW cooling, 43.76 kW input, COP 2.87 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland 6DUNR49ML-AWD (R22 Discus recip, 50 Hz, MD)

R22 compressor — 125.8 kW cooling, 43.76 kW input, COP 2.87 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland 6DUXR49ME-TSE (R22 Discus recip, 50 Hz, MD)

R22 compressor — 125.8 kW cooling, 43.76 kW input, COP 2.87 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland 6DUXR49ML-AWD (R22 Discus recip, 50 Hz, MD)

R22 compressor — 125.8 kW cooling, 43.76 kW input, COP 2.87 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland 6DVNR49ME-TSE (R22 Discus recip, 50 Hz, MD)

R22 compressor — 125.8 kW cooling, 43.76 kW input, COP 2.87 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland 6DVNR49ML-AWD (R22 Discus recip, 50 Hz, MD)

R22 compressor — 125.8 kW cooling, 43.76 kW input, COP 2.87 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland 6DVXR49ME-TSE (R22 Discus recip, 50 Hz, MD)

R22 compressor — 125.8 kW cooling, 43.76 kW input, COP 2.87 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland 6DVXR49ML-AWD (R22 Discus recip, 50 Hz, MD)

R22 compressor — 125.8 kW cooling, 43.76 kW input, COP 2.87 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland 6DZNR49ME-TSE (R22 Discus recip, 50 Hz, MD)

R22 compressor — 125.8 kW cooling, 43.76 kW input, COP 2.87 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland CR18K6-PFV (R22 hermetic recip, 50 Hz, AC)

R22 compressor — 4.3 kW cooling, 1.44 kW input, COP 2.98 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland CR21K8M-PFZ (R22 hermetic recip, 50 Hz, HT)

R22 compressor — 5.1 kW cooling, 1.60 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland CR22K6-TFD (R22 hermetic recip, 50 Hz, AC)

R22 compressor — 5.4 kW cooling, 1.76 kW input, COP 3.07 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland CR22K6E-TFD (R22 hermetic recip, 50 Hz, AC)

R22 compressor — 5.4 kW cooling, 1.76 kW input, COP 3.07 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland CR22K6M-PF1 (R22 hermetic recip, 50 Hz, HT)

R22 compressor — 5.4 kW cooling, 1.76 kW input, COP 3.08 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland CR22K8M-PFZ (R22 hermetic recip, 50 Hz, HT)

R22 compressor — 5.3 kW cooling, 1.70 kW input, COP 3.12 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland CR23K8M-PF1 (R22 hermetic recip, 50 Hz, HT)

R22 compressor — 5.7 kW cooling, 1.77 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland CR24K6M-TFD (R22 hermetic recip, 50 Hz, HT)

R22 compressor — 5.8 kW cooling, 1.97 kW input, COP 2.96 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland CR27K9M-PFZ (R22 hermetic recip, 50 Hz, HT)

R22 compressor — 6.3 kW cooling, 1.99 kW input, COP 3.19 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland CR30K6M-PF1 (R22 hermetic recip, 50 Hz, HT)

R22 compressor — 7.1 kW cooling, 2.36 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland CR30K8M-PF1 (R22 hermetic recip, 50 Hz, HT)

R22 compressor — 7.3 kW cooling, 2.32 kW input, COP 3.16 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland CR31K8M-PFZ (R22 hermetic recip, 50 Hz, HT)

R22 compressor — 7.7 kW cooling, 2.45 kW input, COP 3.14 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland CR32K6M-PFZ (R22 hermetic recip, 50 Hz, HT)

R22 compressor — 8.0 kW cooling, 2.73 kW input, COP 2.92 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland CR33K8M-PFZ (R22 hermetic recip, 50 Hz, HT)

R22 compressor — 7.7 kW cooling, 2.51 kW input, COP 3.06 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC

Copeland CR34K6M-TFD (R22 hermetic recip, 50 Hz, HT)

R22 compressor — 8.3 kW cooling, 2.82 kW input, COP 2.93 at the AHRI 7.2/54.4 °C rating point.

catalogR22
Compressor · EU, APAC
1234Next ›

How the model reads against Copeland's data

Compressor maps converted from the vendor's own rating database4 776 mapsevery basis median within 3.2 % of the nomenclature; the vendor's polynomial substituted exactly, never refitted

From the validation page; every row is held by a test.

Worked cases that run Copeland machines

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.

HVAC Builder · engineering results are estimates from catalog data and published correlations: ASHRAE, IAPWS-IF97, AHRI 540, EnergyPlus, CoolProp · weather data: PVGIS © European Union, JRC · contact: leads@hvacbuilder.app · bugs: bugs@hvacbuilder.app · validation · changelog · manufacturers · catalog · tools · Systems · Components · Suppliers · Privacy