Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. We confirm each claim by hand before it takes effect; from then the page and its listings are yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page

Listings

All kindsRecovery core 71
All marketsNA 71
Any certificationAHRI 1060 (air-to-air energy recovery component) 71
SortNewestName A–ZSupplier A–ZCapacity ↑Capacity ↓

Showing 25–48 of 71

DRI HRW-2200-MS 200 (H.M. & SEG) (N) total energy recovery wheel

by DRI

Sensible-and-latent recovery core, 1.765 m² face a stream, 3.53 / 3.53 m³/s.

catalogAHRI 1060 (air-to-air energy recovery component)
Recovery core · NA

DRI HRW-2200-MS 200 (MonoG) (N) total energy recovery wheel

by DRI

Sensible-and-latent recovery core, 1.765 m² face a stream, 3.53 / 3.53 m³/s.

catalogAHRI 1060 (air-to-air energy recovery component)
Recovery core · NA

DRI HRW-2200-MS 270A (H.M. & SEG) (N) total energy recovery wheel

by DRI

Sensible-and-latent recovery core, 1.765 m² face a stream, 3.53 / 3.53 m³/s.

catalogAHRI 1060 (air-to-air energy recovery component)
Recovery core · NA

DRI HRW-2200-MS 270A (MonoG) (N) total energy recovery wheel

by DRI

Sensible-and-latent recovery core, 1.765 m² face a stream, 3.53 / 3.53 m³/s.

catalogAHRI 1060 (air-to-air energy recovery component)
Recovery core · NA

DRI HRW-2400-MS 200 (H.M. & SEG) (N) total energy recovery wheel

by DRI

Sensible-and-latent recovery core, 2.113 m² face a stream, 4.23 / 4.23 m³/s.

catalogAHRI 1060 (air-to-air energy recovery component)
Recovery core · NA

DRI HRW-2400-MS 200 (MonoG) (N) total energy recovery wheel

by DRI

Sensible-and-latent recovery core, 2.113 m² face a stream, 4.23 / 4.23 m³/s.

catalogAHRI 1060 (air-to-air energy recovery component)
Recovery core · NA

DRI HRW-2400-MS 270A (H.M. & SEG) (N) total energy recovery wheel

by DRI

Sensible-and-latent recovery core, 2.113 m² face a stream, 4.23 / 4.23 m³/s.

catalogAHRI 1060 (air-to-air energy recovery component)
Recovery core · NA

DRI HRW-2400-MS 270A (MonoG) (N) total energy recovery wheel

by DRI

Sensible-and-latent recovery core, 2.113 m² face a stream, 4.23 / 4.23 m³/s.

catalogAHRI 1060 (air-to-air energy recovery component)
Recovery core · NA

DRI HRW-2600-MS 200 (N) total energy recovery wheel

by DRI

Sensible-and-latent recovery core, 2.493 m² face a stream, 4.99 / 4.99 m³/s.

catalogAHRI 1060 (air-to-air energy recovery component)
Recovery core · NA

DRI HRW-2600-MS 270A (N) total energy recovery wheel

by DRI

Sensible-and-latent recovery core, 2.493 m² face a stream, 4.99 / 4.99 m³/s.

catalogAHRI 1060 (air-to-air energy recovery component)
Recovery core · NA

DRI HRW-2800-MS 200 (N) total energy recovery wheel

by DRI

Sensible-and-latent recovery core, 2.903 m² face a stream, 5.81 / 5.81 m³/s.

catalogAHRI 1060 (air-to-air energy recovery component)
Recovery core · NA

DRI HRW-2800-MS 270A (N) total energy recovery wheel

by DRI

Sensible-and-latent recovery core, 2.903 m² face a stream, 5.81 / 5.81 m³/s.

catalogAHRI 1060 (air-to-air energy recovery component)
Recovery core · NA

DRI HRW-3000-MS 200 (N) total energy recovery wheel

by DRI

Sensible-and-latent recovery core, 3.344 m² face a stream, 6.69 / 6.69 m³/s.

catalogAHRI 1060 (air-to-air energy recovery component)
Recovery core · NA

DRI HRW-3000-MS 270A (N) total energy recovery wheel

by DRI

Sensible-and-latent recovery core, 3.344 m² face a stream, 6.69 / 6.69 m³/s.

catalogAHRI 1060 (air-to-air energy recovery component)
Recovery core · NA

DRI HRW-3200-MS 200 (N) total energy recovery wheel

by DRI

Sensible-and-latent recovery core, 3.817 m² face a stream, 7.63 / 7.63 m³/s.

catalogAHRI 1060 (air-to-air energy recovery component)
Recovery core · NA

DRI HRW-3200-MS 270A (N) total energy recovery wheel

by DRI

Sensible-and-latent recovery core, 3.817 m² face a stream, 7.63 / 7.63 m³/s.

catalogAHRI 1060 (air-to-air energy recovery component)
Recovery core · NA

DRI HRW-3400-MS 200 (N) total energy recovery wheel

by DRI

Sensible-and-latent recovery core, 4.320 m² face a stream, 8.64 / 8.64 m³/s.

catalogAHRI 1060 (air-to-air energy recovery component)
Recovery core · NA

DRI HRW-3400-MS 270A (N) total energy recovery wheel

by DRI

Sensible-and-latent recovery core, 4.320 m² face a stream, 8.64 / 8.64 m³/s.

catalogAHRI 1060 (air-to-air energy recovery component)
Recovery core · NA

DRI HRW-3600-MS 200 (N) total energy recovery wheel

by DRI

Sensible-and-latent recovery core, 4.855 m² face a stream, 9.71 / 9.71 m³/s.

catalogAHRI 1060 (air-to-air energy recovery component)
Recovery core · NA

DRI HRW-3600-MS 270A (N) total energy recovery wheel

by DRI

Sensible-and-latent recovery core, 4.855 m² face a stream, 9.71 / 9.71 m³/s.

catalogAHRI 1060 (air-to-air energy recovery component)
Recovery core · NA

DRI HRW-3800-MS 200 (N) total energy recovery wheel

by DRI

Sensible-and-latent recovery core, 5.420 m² face a stream, 10.84 / 10.84 m³/s.

catalogAHRI 1060 (air-to-air energy recovery component)
Recovery core · NA

DRI HRW-3800-MS 270A (N) total energy recovery wheel

by DRI

Sensible-and-latent recovery core, 5.420 m² face a stream, 10.84 / 10.84 m³/s.

catalogAHRI 1060 (air-to-air energy recovery component)
Recovery core · NA

DRI HRW-400-MS 200 (N) total energy recovery wheel

by DRI

Sensible-and-latent recovery core, 0.050 m² face a stream, 0.10 / 0.10 m³/s.

catalogAHRI 1060 (air-to-air energy recovery component)
Recovery core · NA

DRI HRW-4000-MS 200 (N) total energy recovery wheel

by DRI

Sensible-and-latent recovery core, 6.017 m² face a stream, 12.03 / 12.03 m³/s.

catalogAHRI 1060 (air-to-air energy recovery component)
Recovery core · NA
‹ Previous123Next ›

How the model reads against DRI's data

Total energy recovery wheels against their maker's own tables: the sensible-and-latent exchanger, both its efficiencies read off face-velocity curves (a latent one that falls with velocity, humidityEffectivenessCurve)71 listings (36 MS-200, 35 MS-270A) at 9 velocities and 2 rating conditions: 1 278 solves, each filled from the catalog by its referencethe solve reads the printed sensible effectiveness exactly on the streams' capacity rates — the model's own definition, which reads its curve on the smaller one, so this holds the face velocity each curve is read at, not the physics — and the printed latent within a point at every velocity (the MS-270A's listings carry its winter row, a point above its summer one). Through the outlet enthalpy it reads every printed total within a point: worst −0.73 (summer) and +0.54 (winter) points on the MS-200, +0.47 and −0.77 on the MS-270A — whose summer latent row would miss its winter total by 1.11 at 3.5 m/s, which is why the winter row is listed. Not within a point on the standard's definition: on the mass flows alone, AHRI 1060's form, the summer sensible reads up to 1.15 points under the printed figure, and more than a point under at 7 of the 18 summer cells (the MS-200 at 1 and 1.5 m/s, the MS-270A at 1 to 3 m/s) — the humid outdoor air's specific heat against the drier return's, 1.28 % — while every winter cell reads exactly. Which definition a listed core should read is open, and recorded with the data. Not carried: the printed pressure drop — 74 to 241 Pa from 1 to 5 m/s on the MS-200, 76 to 325 on the MS-270A, where a core reads the model's default of 38 to 938 Pa — and the rotor's drive motor (0.09 to 1.1 kW)

From the validation page; every row is held by a test.

Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.