Copeland YFH04KAE-TF5 (R407C scroll, 60 Hz, LT)
Compressor — R407C compressor — 0.75 kW cooling, 0.83 kW input, COP 0.91 at -35/35 °C (evaporating/condensing), inside its published envelope.
A Copeland listing, from the manufacturer's published data.
Units: SI · US customary
Published specification
| Model | Copeland YFH04KAE-TF5 (R407C scroll, 60 Hz, LT) |
| Refrigerant | R407C |
| Performance data | AHRI 540 / EN 12900 10-coefficient map |
| Reference superheat / subcool | 30.5 / 0.0 K |
| Cooling capacity @ -35/35 °C | 0.75 kW |
| Input power @ -35/35 °C | 0.83 kW |
| COP @ -35/35 °C | 0.91 |
The map across its envelope
AHRI 540 / EN 12900 ten-coefficient polynomials in evaporating and condensing temperature, rated at 30.5 K superheat and 0.0 K subcooling; the solver corrects them to the operating superheat and subcooling. Envelope: the manufacturer's 6-sided polygon. The mass-flow coefficient set is published too, and the solver checks it against the capacity set.
| te / tc °C | Capacity kW | Power kW | COP |
|---|---|---|---|
| -35 / 35 | 0.75 | 0.83 | 0.91 |
| -25 / 35 | 1.25 | 0.88 | 1.42 |
| -20 / 35 | 1.60 | 0.90 | 1.77 |
Conditions across the published envelope, which does not reach the AHRI air-conditioning rating point (7.2/54.4 °C) — the map is not read there. The whole map — every condition, the envelope and the curves — is in the builder: open this machine in the app. It solves any point inside the envelope, and warns past it.
Open this compressor in the app — the compressor-map tab, with its rating at any condition, its envelope, capacity and power lines and curves plotted, and the refrigerant's pressure–temperature chart a click away; or open the builder and pick it from the catalog picker — the solver runs it with the catalog's own figures, at your design point or across a year of weather.
Same family
| Compressor | Copeland YFH04KAE-TF5 (R404A scroll, 50 Hz, LT) | R404A |
| Compressor | Copeland YFH04KAE-TF5 (R404A scroll, 60 Hz, LT) | R404A |
| Compressor | Copeland YFH04KAE-TF5 (R407A scroll, 50 Hz, LT) | R407A |
| Compressor | Copeland YFH04KAE-TF5 (R407A scroll, 60 Hz, LT) | R407A |
| Compressor | Copeland YFH04KAE-TF5 (R407C scroll, 50 Hz, LT) | R407C |
| Compressor | Copeland YFH04KAE-TF5 (R407F scroll, 50 Hz, LT) | R407F |
| Compressor | Copeland YFH04KAE-TF5 (R407F scroll, 60 Hz, LT) | R407F |
| Compressor | Copeland YFH04KAE-TF5 (R448A scroll, 50 Hz, LT) | R448A |
| Compressor | Copeland YFH04KAE-TF5 (R448A scroll, 60 Hz, LT) | R448A |
| Compressor | Copeland YFH04KAE-TF5 (R449A scroll, 50 Hz, LT) | R449A |
| Compressor | Copeland YFH04KAE-TF5 (R449A scroll, 60 Hz, LT) | R449A |
| Compressor | Copeland YFH04KAE-TF5 (R507 scroll, 50 Hz, LT) | R507 |
How the model reads against this maker's data
| Compressor maps converted from the vendor's own rating database | 5 452 maps (4 776 of the worldwide publication, 676 of the Asia and China publications listed for their region) | every basis median within 3.1 % of the nomenclature; the vendor's polynomial substituted exactly, never refitted; each map's superheat and subcooling reference read off its own rating row (the ZW heat pumps at 5 K, the ZH/YH at 10 K, the Discus at 25 K, the small hermetics at a 40 °F return gas) |
| The compressor map's superheat/subcooling correction — AHRI-rated maps read at EN 12900 conditions | 99 R410A (13 models) + 22 R407C + 35 R134a | the corrected map reads the guide's capacity at −0.1 % mean / 1.0 % RMS on R410A, flat across evaporating temperature, every model within ±1.6 %; R407C nominal +1.0 % / 1.8 % (with the subcooling measured from the bubble point, as AHRI 540 Appendix C reads it — +0.3 % when it was measured from the dew point, a difference inside the band either way); R134a +1.5 % / 1.8 %. The uncorrected polynomial reads +9 to +11 %. The R404A refrigeration scrolls, rated at a return gas rather than a superheat, read the guide's 20 °C return-gas tables at +0.7 % / 1.5 % from −15 to −5 °C (88 points) — there the correction is a one-per-cent matter either way. Not held: the heat-pump scrolls, for which the guide prints heating capacity — and one R407C row (ZRD72KCE) disagrees with its map by a quarter and is recorded as a catalogue fault |
| Drake Chillers PAC360D (30 HP, R407C and R404A), modelled — one air-cooled chiller on the catalog's maps of the compressor its sheet names, on both refrigerants it is sold on | 44 + the pinned cell | the pinned 45 °F row within −1.9 to +1.7 % on tons and −2.8 to 0 % on compressor power; every water row's ambient trend on both fluids, each cell against its row's 95 °F cell, at 1.2 % RMS on tons (worst 3.3) and 1.9 % on power (worst 4.7); and at 55 °F, the one leaving temperature both tables print, R404A's capacity over R407C's within −1.6 to −2.9 % of the sheet's ratio. Recorded, not held to the sheet: the sheet holds its evaporator at one approach whatever the duty ("selected upon requirements"), so one fixed conductance reads +6 to +11 % at 35 °F and −14 to −15 % at 65 °F; R404A's power over R407C's reads 4.9–8.7 % above the sheet's at 55 °F — the condenser model holds the refrigerant at its dew point, which credits R407C with half its 4.7 K glide, while the sheet's two tables are one condenser on the mean condensing temperature; the 0–25 °F R404A rows want glycol |
| KeepRite KEZ Generation D scroll condensing units, modelled — four frames on the catalog's maps of the Copeland scrolls the manual names, against its capacity tables on four refrigerants | 806 cells on 15 tables (KEZA009H8, KEZA050H8, KEZA150H8, KEZA150L8), four of them pinned | on the one condenser each, R404A within 0.5–1.1 % RMS (worst +3.4 %) and R407A, R407C and R448A within 1.3–3.7 % RMS (worst −6.9 and +6.7 %, both R448A), every table's mean within a point of the day's — a band no table read one ambient column or one suction row over meets; the 50 cells the manual shades for a 20 °F superheat limit read like the rest. What it tests is the four maps at their own rating basis more than the condenser: the tables are three significant figures with no power, and on three of the four frames the pinned airflow is not air the printed fans could move — through the stated coil it takes 1.9–4.1 times the air power they could give at the best static efficiency of a catalog axial fan of their size, so it stands for the conductance the tables ask for. The suction temperature reads as a dew point — taken as a mid-point the R448A tables read 10–11 % high. Across the manual's 18 cooler frames with a map the same reading runs 1.5–5.2 % RMS, KEZA061H8's R407C table apart (8–46 % under its map), and 10 of them ask a condenser their fans could not drive; the freezer tables mostly print more than their maps give near the ambient — three cannot be reached at any airflow, none is air its fans could move — and are recorded, not modelled |
From the validation page; every row is held by a test.
Listed from published data; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.