Copeland ZB95KQE-TFD (R134A scroll, 60 Hz, HT)

Compressor — R134a compressor — 27.6 kW cooling, 9.73 kW input, COP 2.84 at the AHRI 7.2/54.4 °C rating point.

A Copeland listing, from the manufacturer's published data.

Published specification

ModelCopeland ZB95KQE-TFD (R134A scroll, 60 Hz, HT)
RefrigerantR134a
Performance dataAHRI 540 / EN 12900 10-coefficient map
Reference superheat / subcool11.1 / 0.0 K
Cooling capacity @ 7.2/54.4 °C27.62 kW
Input power @ 7.2/54.4 °C9.73 kW
COP @ 7.2/54.4 °C2.84

The map across its envelope

AHRI 540 / EN 12900 ten-coefficient polynomials in evaporating and condensing temperature, rated at 11.1 K superheat and 0.0 K subcooling; the solver corrects them to the operating superheat and subcooling. Envelope: the manufacturer's 6-sided polygon. The mass-flow coefficient set is published too, and the solver checks it against the capacity set.

te / tc °CCapacity kWPower kWCOP
-10 / 3017.975.663.17
-10 / 5013.858.491.63
0 / 3027.506.024.57
0 / 5021.918.742.51
0 / 7015.2213.211.15
10 / 3040.616.496.26
10 / 5032.689.043.61
10 / 7023.7713.331.78

Points on a 10 K grid inside the published envelope; the builder solves any point in it, and warns past it.

Open the builder and pick this listing from the catalog picker — the solver runs it with the catalog's own figures, at your design point or across a year of weather.

Same family

compressorsCopeland ZB95KQE-TFD (R134A scroll, 50 Hz, HT)R134a
compressorsCopeland ZB95KQE-TFD (R404A scroll, 50 Hz, MD)R404A
compressorsCopeland ZB95KQE-TFD (R404A scroll, 60 Hz, MD)R404A
compressorsCopeland ZB95KQE-TF7 (R407C scroll, 60 Hz, HD)R407C

How the model reads against this maker's data

Compressor maps converted from the vendor's own rating database5 452 maps (4 776 of the worldwide publication, 676 of the Asia and China publications listed for their region)every basis median within 3.1 % of the nomenclature; the vendor's polynomial substituted exactly, never refitted; each map's superheat and subcooling reference read off its own rating row (the ZW heat pumps at 5 K, the ZH/YH at 10 K, the Discus at 25 K, the small hermetics at a 40 °F return gas)
The compressor map's superheat/subcooling correction — AHRI-rated maps read at EN 12900 conditions99 R410A (13 models) + 22 R407C + 35 R134athe corrected map reads the guide's capacity at −0.1 % mean / 1.0 % RMS on R410A, flat across evaporating temperature, every model within ±1.6 %; R407C nominal +0.3 % / 1.6 %; R134a +1.5 % / 1.8 %. The uncorrected polynomial reads +9 to +11 %. The R404A refrigeration scrolls, rated at a return gas rather than a superheat, read the guide's 20 °C return-gas tables at +0.7 % / 1.5 % from −15 to −5 °C (88 points) — there the correction is a one-per-cent matter either way. Not held: the heat-pump scrolls, for which the guide prints heating capacity — and one R407C row (ZRD72KCE) disagrees with its map by a quarter and is recorded as a catalogue fault

From the validation page; every row is held by a test.

Listed from published data; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.

HVAC Builder · engineering results are estimates from catalog data and published correlations: ASHRAE, IAPWS-IF97, AHRI 540, EnergyPlus, CoolProp · weather data: PVGIS © European Union, JRC · contact: leads@hvacbuilder.app · bugs: bugs@hvacbuilder.app · validation · changelog · manufacturers · catalog · tools · Systems · Components · Suppliers · Privacy