Wieland WKC 20 coaxial condenser (32.7 kW at 2.7 m³/h of 30 °C water, 45 °C condensing, R410A)

Pipe-in-pipe exchanger — Coaxial condenser — 32.7 kW into water 30.0 to 40.4 °C, condensing at 45.0 °C, 0.75 kg/s.

A Wieland listing, from the manufacturer's published data.

Units: SI · US customary

Published specification

Rated water30.0 to 40.4 °C
Rated condensing temperature45.0 °C
Water flow at the rating0.75 kg/s
Duty at the rating32.7 kW
Conductance (from the rating)3.73 kW/K

Manufacturer's product page

Open this part in the app — as a component of its own, carrying the catalog's figures; or open the builder and pick it from the catalog picker. The solver runs it with the catalog's own data, at your design point or across a year of weather.

Same family

Pipe-in-pipe exchangerWieland WKC 10 coaxial condenser (9.6 kW at 1.0 m³/h of 30 °C water, 45 °C condensing, R410A)
Pipe-in-pipe exchangerWieland WKC 15 coaxial condenser (21.0 kW at 1.6 m³/h of 30 °C water, 45 °C condensing, R410A)
Pipe-in-pipe exchangerWieland WKC 45 coaxial condenser (70.0 kW at 5.4 m³/h of 30 °C water, 45 °C condensing, R410A)

How the model reads against this maker's data

Coaxial exchanger model against a maker's measured condenser and evaporator tables, one conductance per model554 over 8 modelsevery rating reproduced exactly. Condensers on R410A (R404A/R507 is printed identical): −13 to +16 % of the printed duty, RMS 7.9 %, the condensing temperature within 3.0 K — at one flow the duty is proportional to the temperature difference as the model has it, but the conductance rises with flow (as flow^0.4 on three of the four) and at the lowest flows the hot gas heats the water past the condensing temperature, which no isothermal model does. Evaporators on R410A: −18 to +63 %, RMS 22 %, within 3.2 K — the conductance rises with flow (flow^0.3–0.5) and with the temperature difference (as boiling that strengthens with the heat flux, and a 5 K suction superheat that takes more of the tube the smaller the difference, would make it), so one conductance over-reads most at a low flow and a 6 K difference. The other refrigerants are R410A times one ratio each — R134a 12 % under on the condensers and 20 % under on the evaporators, R404A/R507 7 % over on the evaporators — which a listing that carries no refrigerant reads as R410A

From the validation page; every row is held by a test.

Listed from published data; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.