Compressors
Compressors from their makers and suppliers, with the specification each publishes and a quote form on every listing.
The builder models these: pick one into a design and it solves on the listing's figures.
Showing 6,937–6,960 of 14,438
| Name | Manufacturer | Rating | Markets | Open in the builder |
|---|---|---|---|---|
| Copeland 6YVXR48ME-TSE (R449A Discus recip, 60 Hz, MD) Catalog | Copeland | R449A compressor — 82.8 kW cooling, 30.25 kW input, COP 2.74 at -15/35 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss MLZ015T4A (R407C scroll, 60 Hz, MT) Catalog | Danfoss | R407C compressor — 6.9 kW cooling, 2.21 kW input, COP 3.11 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh AJ4480P-FZ3A (R448A hermetic, HBP, EN12900, 50 Hz) Catalog | Tecumseh | R448A compressor — 1.9 kW cooling, 0.89 kW input, COP 2.11 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 6YZNF10ME-TSE (R449A Discus recip, 60 Hz, LD) Catalog | Copeland | R449A compressor — 31.9 kW cooling, 18.29 kW input, COP 1.74 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss MT080-4 (R22 hermetic reciprocating, 50 Hz, MT) Catalog | Danfoss | R22 compressor — 19.2 kW cooling, 7.08 kW input, COP 2.72 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh FH4532Z-KZ1A (R449A hermetic, HBP, EN12900, 60 Hz) Catalog | Tecumseh | R449A compressor — 7.6 kW cooling, 3.00 kW input, COP 2.55 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 6YZNR48ME-TSE (R449A Discus recip, 60 Hz, MD) Catalog | Copeland | R449A compressor — 82.8 kW cooling, 30.25 kW input, COP 2.74 at -15/35 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss MTZ022-1 (R134a hermetic reciprocating, 60 Hz, A/C) Catalog | Danfoss | R134a compressor — 3.8 kW cooling, 1.50 kW input, COP 2.52 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh AE4470Z-FZ3C (R448A hermetic, HBP, ASHRAE, 50 Hz) Catalog | Tecumseh | R448A compressor — 1.9 kW cooling, 0.78 kW input, COP 2.41 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland AFE11C4E-IAV (R449A hermetic recip, 60 Hz, LT) Catalog | Copeland | R449A compressor — 0.26 kW cooling, 0.23 kW input, COP 1.13 at -25/40 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss NTZ136-1B (R404A hermetic reciprocating, 60 Hz, LT) Catalog | Danfoss | R404A compressor — 2.1 kW cooling, 2.65 kW input, COP 0.78 at -40/45 °C (evaporating/condensing), inside its published envelope. | Open in the builder | |
| Tecumseh AJ4480P-FZ3A (R449A hermetic, HBP, EN12900, 50 Hz) Catalog | Tecumseh | R449A compressor — 1.9 kW cooling, 0.89 kW input, COP 2.11 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland AFF10C1E-IAA (R450A hermetic recip, 60 Hz, EF) Catalog | Copeland | R450A compressor — 0.28 kW cooling, 0.21 kW input, COP 1.32 at -25/40 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss PSH030-4G (R410A scroll, 50 Hz) Catalog | Danfoss | R410A compressor — 32.7 kW cooling, 11.17 kW input, COP 2.93 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh FH4532Z-KZ1A (R452A hermetic, HBP, EN12900, 50 Hz) Catalog | Tecumseh | R452A compressor — 6.4 kW cooling, 2.59 kW input, COP 2.48 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland ARE25C4E-IAA (R134A hermetic recip, 60 Hz, HT) Catalog | Copeland | R134a compressor — 0.74 kW cooling, 0.36 kW input, COP 2.06 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Danfoss SH380-7 (R410A scroll, 50 Hz, A/C) Catalog | Danfoss | R410A compressor — 79.7 kW cooling, 28.41 kW input, COP 2.81 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh AE4470Z-FZ3C (R449A hermetic, HBP, ASHRAE, 50 Hz) Catalog | Tecumseh | R449A compressor — 1.9 kW cooling, 0.78 kW input, COP 2.41 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland ASE14C4E-IAA (R449A hermetic recip, 60 Hz, MT) Catalog | Copeland | R449A compressor — 0.27 kW cooling, 0.25 kW input, COP 1.08 at -20/45 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss SZ125-4 (R407C scroll, 50 Hz, A/C) Catalog | Danfoss | R407C compressor — 28.6 kW cooling, 8.95 kW input, COP 3.19 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh AJ4480P-FZ3A (R452A hermetic, HBP, EN12900, 50 Hz) Catalog | Tecumseh | R452A compressor — 1.8 kW cooling, 0.93 kW input, COP 1.97 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland ASM17C7U-IAI (R290 hermetic recip, 50 Hz, EM) Catalog | Copeland | R290 compressor — 0.17 kW cooling, 0.13 kW input, COP 1.26 at -30/40 °C (evaporating/condensing), inside its published envelope. | EU, APAC | Open in the builder |
| Danfoss VZH088BJ (R410A inverter scroll, A/C) Catalog | Danfoss | R410A compressor — 41.1 kW cooling, 15.74 kW input, COP 2.61 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh FH4532Z-KZ1A (R452A hermetic, HBP, EN12900, 60 Hz) Catalog | Tecumseh | R452A compressor — 7.5 kW cooling, 3.14 kW input, COP 2.38 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors