Compressors
Compressors from their makers and suppliers, with the specification each publishes and a quote form on every listing.
The builder models these: pick one into a design and it solves on the listing's figures.
Showing 7,249–7,272 of 14,438
| Name | Manufacturer | Rating | Markets | Open in the builder |
|---|---|---|---|---|
| Copeland 4DJNF76KL-TSK (R407F Discus recip, 60 Hz, LD) Catalog | Copeland | R407F compressor — 18.2 kW cooling, 10.34 kW input, COP 1.76 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss HRM058T1 (R22 scroll, 60 Hz, A/C) Catalog | Danfoss | R22 compressor — 17.0 kW cooling, 5.13 kW input, COP 3.32 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh FH4538Z-KZ1A (R449A hermetic, HBP, EN12900, 50 Hz) Catalog | Tecumseh | R449A compressor — 8.2 kW cooling, 3.15 kW input, COP 2.61 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 4DJNR28ML-TSK (R407A Discus recip, 60 Hz, AC) Catalog | Copeland | R407A compressor — 94.4 kW cooling, 30.98 kW input, COP 3.05 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Danfoss LLZ015T9A (R448A scroll, 60 Hz, LT) Catalog | Danfoss | R448A compressor — 3.8 kW cooling, 2.85 kW input, COP 1.32 at -35/30 °C (evaporating/condensing), inside its published envelope. | Open in the builder | |
| Tecumseh AJ4510P-FZ3A (R404A hermetic, HBP, EN12900, 50 Hz) Catalog | Tecumseh | R404A compressor — 2.3 kW cooling, 1.19 kW input, COP 1.91 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 4DJXF76KL-TSK (R448A Discus recip, 60 Hz, LD) Catalog | Copeland | R448A compressor — 19.5 kW cooling, 11.01 kW input, COP 1.77 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss MLZ015T4A (R513A scroll, 50 Hz, MT) Catalog | Danfoss | R513A compressor — 3.6 kW cooling, 1.35 kW input, COP 2.67 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh FH4538Z-KZ1A (R449A hermetic, HBP, EN12900, 60 Hz) Catalog | Tecumseh | R449A compressor — 9.4 kW cooling, 3.84 kW input, COP 2.45 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 4DJXR28ME-TSK (R407F Discus recip, 50 Hz, AC) Catalog | Copeland | R407F compressor — 78.6 kW cooling, 25.82 kW input, COP 3.05 at the AHRI 7.2/54.4 °C rating point. | EU, APAC | Open in the builder |
| Danfoss MT100-7 (R22 hermetic reciprocating, 60 Hz, A/C) Catalog | Danfoss | R22 compressor — 28.1 kW cooling, 9.58 kW input, COP 2.93 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh AJ4510P-FZ3A (R448A hermetic, HBP, EN12900, 50 Hz) Catalog | Tecumseh | R448A compressor — 2.3 kW cooling, 1.10 kW input, COP 2.13 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 4DK3S16ML-TSK (R449A Discus recip, 60 Hz, MD) Catalog | Copeland | R449A compressor — 33.7 kW cooling, 12.52 kW input, COP 2.69 at -20/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss MTZ022-1 (R454C hermetic reciprocating, 60 Hz) Catalog | Danfoss | R454C compressor — 5.4 kW cooling, 2.16 kW input, COP 2.52 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh FH4538Z-KZ1A (R452A hermetic, HBP, EN12900, 50 Hz) Catalog | Tecumseh | R452A compressor — 8.0 kW cooling, 3.30 kW input, COP 2.44 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 4DKNR22ME-TSK (R448A Discus recip, 60 Hz, MD) Catalog | Copeland | R448A compressor — 40.1 kW cooling, 14.45 kW input, COP 2.77 at -15/35 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss NTZ136-4B (R454C hermetic reciprocating, 60 Hz) Catalog | Danfoss | R454C compressor — 4.3 kW cooling, 3.21 kW input, COP 1.34 at -30/35 °C (evaporating/condensing), inside its published envelope. | Open in the builder | |
| Tecumseh AJ4510P-FZ3A (R449A hermetic, HBP, EN12900, 50 Hz) Catalog | Tecumseh | R449A compressor — 2.3 kW cooling, 1.10 kW input, COP 2.13 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 4DKNS16ML-TSK (R449A Discus recip, 60 Hz, MD) Catalog | Copeland | R449A compressor — 33.7 kW cooling, 12.52 kW input, COP 2.69 at -20/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss PSH034-3E (R410A scroll, 60 Hz) Catalog | Danfoss | R410A compressor — 45.4 kW cooling, 15.00 kW input, COP 3.03 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh FH4538Z-KZ1A (R452A hermetic, HBP, EN12900, 60 Hz) Catalog | Tecumseh | R452A compressor — 9.2 kW cooling, 4.02 kW input, COP 2.29 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |
| Copeland 4DRNR28ML-TSK (R407A Discus recip, 60 Hz, AC) Catalog | Copeland | R407A compressor — 94.4 kW cooling, 30.98 kW input, COP 3.05 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Danfoss SZ147-4 (R407C scroll, 60 Hz, A/C) Catalog | Danfoss | R407C compressor — 42.3 kW cooling, 12.03 kW input, COP 3.52 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Tecumseh AJ4510P-FZ3A (R452A hermetic, HBP, EN12900, 50 Hz) Catalog | Tecumseh | R452A compressor — 2.3 kW cooling, 1.15 kW input, COP 2.00 at the AHRI 7.2/54.4 °C rating point. | EU | Open in the builder |