All categories

Compressors

Compressors from their makers and suppliers, with the specification each publishes and a quote form on every listing.

The builder models these: pick one into a design and it solves on the listing's figures.

Suppliers 45Systems 3,474Components 15,410Accessories 0

Showing 7,681–7,704 of 14,438

NameManufacturerRatingMarketsOpen in the builder
Copeland 4DHNR22ME-TSK (R448A Discus recip, 60 Hz, MD) CatalogCopelandR448A compressor — 40.1 kW cooling, 14.45 kW input, COP 2.77 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss LLZ018T2C (R404A scroll, 50 Hz, LT) CatalogDanfossR404A compressor — 4.5 kW cooling, 2.81 kW input, COP 1.61 at -35/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Tecumseh AJ4517P-KZ1A (R452A hermetic, HBP, EN12900, 50 Hz) CatalogTecumsehR452A compressor — 3.4 kW cooling, 1.54 kW input, COP 2.22 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DHXR22ME-TSK (R407F Discus recip, 60 Hz, AC) CatalogCopelandR407F compressor — 80.0 kW cooling, 25.26 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss MLZ015T4B (R449A scroll, 50 Hz, MT) CatalogDanfossR449A compressor — 5.5 kW cooling, 2.13 kW input, COP 2.56 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4517P-KZ1A (R452A hermetic, HBP, EN12900, 60 Hz) CatalogTecumsehR452A compressor — 4.0 kW cooling, 1.89 kW input, COP 2.13 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DJNF76KL-TSK (R448A Discus recip, 60 Hz, LD) CatalogCopelandR448A compressor — 19.5 kW cooling, 11.01 kW input, COP 1.77 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MT144-7 (R22 hermetic reciprocating, 50 Hz, MT) CatalogDanfossR22 compressor — 34.3 kW cooling, 11.95 kW input, COP 2.87 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4517P-KZ1A (R454C hermetic, HBP, EN12900, 50 Hz) CatalogTecumsehR454C compressor — 3.1 kW cooling, 1.25 kW input, COP 2.50 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DJNR28ML-TSK (R407C Discus recip, 60 Hz, AC) CatalogCopelandR407C compressor — 87.7 kW cooling, 29.41 kW input, COP 2.98 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss MTZ022-3 (R455A hermetic reciprocating, 60 Hz) CatalogDanfossR455A compressor — 5.7 kW cooling, 2.36 kW input, COP 2.43 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4517P-KZ1A (R454C hermetic, HBP, EN12900, 60 Hz) CatalogTecumsehR454C compressor — 3.7 kW cooling, 1.53 kW input, COP 2.40 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DJXR28ME-TSK (R407F Discus recip, 60 Hz, AC) CatalogCopelandR407F compressor — 94.4 kW cooling, 30.98 kW input, COP 3.05 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss NTZ271-3B (R404A hermetic reciprocating, 60 Hz, LT) CatalogDanfossR404A compressor — 5.0 kW cooling, 5.44 kW input, COP 0.92 at -40/45 °C (evaporating/condensing), inside its published envelope.Open in the builder
Tecumseh AJ4517P-KZ1A (R455A hermetic, HBP, EN12900, 50 Hz) CatalogTecumsehR455A compressor — 3.4 kW cooling, 1.34 kW input, COP 2.50 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DKNR22ML-TSK (R407A Discus recip, 60 Hz, AC) CatalogCopelandR407A compressor — 80.0 kW cooling, 25.26 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss PSH034-4F (R410A scroll, 60 Hz) CatalogDanfossR410A compressor — 45.4 kW cooling, 15.00 kW input, COP 3.03 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4517P-KZ1A (R455A hermetic, HBP, EN12900, 60 Hz) CatalogTecumsehR455A compressor — 3.9 kW cooling, 1.64 kW input, COP 2.40 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4DRNR28ML-TSK (R407C Discus recip, 60 Hz, AC) CatalogCopelandR407C compressor — 87.7 kW cooling, 29.41 kW input, COP 2.98 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss SZ148-6 (R404A scroll, 50 Hz, A/C) CatalogDanfossR404A compressor — 31.3 kW cooling, 12.07 kW input, COP 2.59 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4517P-TZ1A (R404A hermetic, HBP, EN12900, 50 Hz) CatalogTecumsehR404A compressor — 3.2 kW cooling, 1.68 kW input, COP 1.93 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 4YANF36KL-TSK (R454C Discus recip, 50 Hz, LD) CatalogCopelandR454C compressor — 8.7 kW cooling, 4.98 kW input, COP 1.75 at -35/30 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss VZH117CHM (R410A inverter scroll) CatalogDanfossR410A compressor — 50.5 kW cooling, 18.10 kW input, COP 2.79 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4517P-TZ1A (R404A hermetic, HBP, EN12900, 60 Hz) CatalogTecumsehR404A compressor — 3.8 kW cooling, 2.04 kW input, COP 1.84 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
‹ Previous1…319320321322323…602Next ›

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors