Compressors

Compressors from their makers and suppliers, with the specification each publishes and a quote form on every listing.

The builder models these: pick one into a design and it solves on the listing's figures.

Suppliers 44Systems 3,474Components 15,410Accessories 0

Showing 13,537–13,560 of 14,438

NameManufacturerRatingMarketsOpen in the builder
Copeland ZB21KCE-TF5 (R404A scroll, 50 Hz, MT) CatalogCopelandR404A compressor — 4.9 kW cooling, 2.05 kW input, COP 2.38 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MLZ076T4 (R407F scroll, 60 Hz, MT) CatalogDanfossR407F compressor — 33.8 kW cooling, 11.78 kW input, COP 2.87 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZBD58KCE-TF5 (R407A scroll, 60 Hz, MT) CatalogCopelandR407A compressor — 13.8 kW cooling, 5.53 kW input, COP 2.49 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ076T4A (R134a scroll, 50 Hz, MT) CatalogDanfossR134a compressor — 17.8 kW cooling, 5.91 kW input, COP 3.01 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZF11K4E-TF5 (R407C scroll, 60 Hz, LL) CatalogCopelandR407C compressor — 3.2 kW cooling, 1.71 kW input, COP 1.87 at -30/25 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ076T4A (R134a scroll, 60 Hz, MT) CatalogDanfossR134a compressor — 21.5 kW cooling, 7.27 kW input, COP 2.96 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZR48KTE-TFD (R407C scroll, 60 Hz, AC) CatalogCopelandR407C compressor — 13.8 kW cooling, 4.33 kW input, COP 3.18 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss MLZ076T4A (R22 scroll, 50 Hz, MT) CatalogDanfossR22 compressor — 28.3 kW cooling, 8.52 kW input, COP 3.31 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZS30K4E-TF5 (R507 scroll, 50 Hz, EM) CatalogCopelandR507 compressor — 4.4 kW cooling, 2.03 kW input, COP 2.16 at -30/25 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MLZ076T4A (R22 scroll, 60 Hz, MT) CatalogDanfossR22 compressor — 34.5 kW cooling, 10.60 kW input, COP 3.26 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland YB45K1E-TFD (R407F scroll, 60 Hz, MT) CatalogCopelandR407F compressor — 14.2 kW cooling, 5.29 kW input, COP 2.69 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ076T4A (R404A scroll, 50 Hz, MT) CatalogDanfossR404A compressor — 24.4 kW cooling, 9.83 kW input, COP 2.49 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland YF09KSE-TF5 (R454A scroll, 60 Hz, LL) CatalogCopelandR454A compressor — 3.8 kW cooling, 1.92 kW input, COP 2.00 at -30/25 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ076T4A (R404A scroll, 60 Hz, MT) CatalogDanfossR404A compressor — 30.4 kW cooling, 12.05 kW input, COP 2.53 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland YS33KAE-TF5 (R454A scroll, 50 Hz, EM) CatalogCopelandR454A compressor — 5.0 kW cooling, 3.16 kW input, COP 1.58 at -25/40 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MLZ076T4A (R407A scroll, 50 Hz, MT) CatalogDanfossR407A compressor — 26.1 kW cooling, 9.48 kW input, COP 2.75 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZB21KCE-TF5 (R404A scroll, 60 Hz, MT) CatalogCopelandR404A compressor — 5.9 kW cooling, 2.46 kW input, COP 2.38 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ076T4A (R407A scroll, 60 Hz, MT) CatalogDanfossR407A compressor — 31.2 kW cooling, 10.88 kW input, COP 2.87 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZBD58KCE-TF5 (R407C scroll, 50 Hz, MT) CatalogCopelandR407C compressor — 20.5 kW cooling, 6.97 kW input, COP 2.94 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Danfoss MLZ076T4A (R407C scroll, 50 Hz, MT) CatalogDanfossR407C compressor — 28.1 kW cooling, 8.88 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZF11K4E-TF5 (R407F scroll, 50 Hz, LL) CatalogCopelandR407F compressor — 2.9 kW cooling, 1.50 kW input, COP 1.93 at -30/25 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MLZ076T4A (R407C scroll, 60 Hz, MT) CatalogDanfossR407C compressor — 33.8 kW cooling, 10.58 kW input, COP 3.19 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZR52K3E-TF5 (R407C scroll, 50 Hz, AC) CatalogCopelandR407C compressor — 12.1 kW cooling, 3.85 kW input, COP 3.15 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Danfoss MLZ076T4A (R407F scroll, 50 Hz, MT) CatalogDanfossR407F compressor — 28.0 kW cooling, 10.02 kW input, COP 2.79 at the AHRI 7.2/54.4 °C rating point.Open in the builder
‹ Previous1…563564565566567…602Next ›