Compressors

Compressors from their makers and suppliers, with the specification each publishes and a quote form on every listing.

The builder models these: pick one into a design and it solves on the listing's figures.

Suppliers 44Systems 3,474Components 15,410Accessories 0

Showing 13,633–13,656 of 14,438

NameManufacturerRatingMarketsOpen in the builder
Copeland ZB21KCE-TF5 (R407F scroll, 50 Hz, MT) CatalogCopelandR407F compressor — 4.4 kW cooling, 1.85 kW input, COP 2.36 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MLZ076T7A (R452A scroll, 60 Hz, MT) CatalogDanfossR452A compressor — 31.3 kW cooling, 11.62 kW input, COP 2.69 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZBD58KCE-TF5 (R448A scroll, 60 Hz, MT) CatalogCopelandR448A compressor — 14.1 kW cooling, 5.64 kW input, COP 2.50 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ076T7A (R513A scroll, 60 Hz, MT) CatalogDanfossR513A compressor — 20.6 kW cooling, 7.53 kW input, COP 2.73 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZF11K4E-TF5 (R449A scroll, 60 Hz, LL) CatalogCopelandR449A compressor — 3.6 kW cooling, 1.86 kW input, COP 1.94 at -30/25 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ076T9 (R134a scroll, 60 Hz, MT) CatalogDanfossR134a compressor — 21.5 kW cooling, 7.27 kW input, COP 2.96 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZR54K5E-TFD (R22 scroll, 60 Hz, AC) CatalogCopelandR22 compressor — 15.7 kW cooling, 4.73 kW input, COP 3.31 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss MLZ076T9 (R22 scroll, 60 Hz, MT) CatalogDanfossR22 compressor — 34.5 kW cooling, 10.60 kW input, COP 3.26 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZS33KAE-TF5 (R404A scroll, 50 Hz, MT) CatalogCopelandR404A compressor — 11.4 kW cooling, 4.44 kW input, COP 2.57 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Danfoss MLZ076T9 (R404A scroll, 60 Hz, MT) CatalogDanfossR404A compressor — 15.9 kW cooling, 7.64 kW input, COP 2.09 at -20/35 °C (evaporating/condensing), inside its published envelope.Open in the builder
Copeland YB45K1E-TFD (R454C scroll, 60 Hz, MT) CatalogCopelandR454C compressor — 12.6 kW cooling, 4.52 kW input, COP 2.78 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ076T9A (R134a scroll, 60 Hz, MT) CatalogDanfossR134a compressor — 21.5 kW cooling, 7.27 kW input, COP 2.96 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland YF10KAE-PFV (R404A scroll, 50 Hz, LL) CatalogCopelandR404A compressor — 2.9 kW cooling, 2.19 kW input, COP 1.34 at -35/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MLZ076T9A (R22 scroll, 60 Hz, MT) CatalogDanfossR22 compressor — 34.5 kW cooling, 10.60 kW input, COP 3.26 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland YS40KAE-TF5 (R404A scroll, 50 Hz, EM) CatalogCopelandR404A compressor — 6.7 kW cooling, 3.47 kW input, COP 1.94 at -25/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MLZ076T9A (R404A scroll, 60 Hz, MT) CatalogDanfossR404A compressor — 29.6 kW cooling, 12.05 kW input, COP 2.46 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZB21KCE-TF5 (R407F scroll, 60 Hz, MT) CatalogCopelandR407F compressor — 5.2 kW cooling, 2.23 kW input, COP 2.36 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ076T9A (R448A scroll, 60 Hz, MT) CatalogDanfossR448A compressor — 32.3 kW cooling, 11.26 kW input, COP 2.87 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZBD58KCE-TF5 (R449A scroll, 50 Hz, MT) CatalogCopelandR449A compressor — 11.8 kW cooling, 4.70 kW input, COP 2.50 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MLZ076T9A (R449A scroll, 60 Hz, MT) CatalogDanfossR449A compressor — 32.3 kW cooling, 11.26 kW input, COP 2.87 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZF11K4E-TF5 (R507 scroll, 50 Hz, LL) CatalogCopelandR507 compressor — 3.6 kW cooling, 1.71 kW input, COP 2.13 at -30/25 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MLZ090T4 (R404A scroll, 50 Hz) CatalogDanfossR404A compressor — 31.2 kW cooling, 11.43 kW input, COP 2.73 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZR54KEE-TFM (R407C scroll, 50 Hz, AC) CatalogCopelandR407C compressor — 12.9 kW cooling, 3.97 kW input, COP 3.26 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Danfoss MLZ116T4 (R404A scroll, 50 Hz, MT) CatalogDanfossR404A compressor — 40.7 kW cooling, 16.52 kW input, COP 2.46 at the AHRI 7.2/54.4 °C rating point.Open in the builder