Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 7,585–7,608 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Tecumseh AJ4461N-XA1A (R134a hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR134a compressor — 1.7 kW cooling, 0.90 kW input, COP 1.94 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ZWD61KBE-TFP (R134A scroll, 50 Hz, HP) CatalogCompressorsCopelandR134a compressor — 13.1 kW cooling, 2.86 kW input, COP 4.57 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Danfoss SM185-9 (R22 scroll, 60 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 54.3 kW cooling, 16.22 kW input, COP 3.35 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh FH4527N-XG1A (R1234yf hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR1234yf compressor — 6.8 kW cooling, 3.00 kW input, COP 2.27 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ZX19KCE-PFJ (R134A scroll, 50 Hz, MT) CatalogCompressorsCopelandR134a compressor — 1.9 kW cooling, 1.19 kW input, COP 1.61 at -15/40 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss SZ120-7 (R407C scroll, 60 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 34.8 kW cooling, 10.75 kW input, COP 3.24 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AE4460Y-FZ3C (R134a hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR134a compressor — 1.3 kW cooling, 0.60 kW input, COP 2.25 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland ZXV080QE-5X9 (R449A variable-speed scroll) CatalogCompressorsCopelandR449A compressor — 28.7 kW cooling, 12.13 kW input, COP 2.37 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Danfoss VZH065CHM (R452B inverter scroll) CatalogCompressorsDanfossR452B compressor — 33.3 kW cooling, 12.14 kW input, COP 2.75 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AG4573P-TZ1A (R448A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR448A compressor — 18.6 kW cooling, 8.53 kW input, COP 2.18 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 2DA3F23KL-TFC (R407F Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407F compressor — 5.2 kW cooling, 3.12 kW input, COP 1.67 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss DSH161-4 (R452B scroll, 60 Hz, A/C) CatalogCompressorsDanfossR452B compressor — 46.9 kW cooling, 13.84 kW input, COP 3.39 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4461N-XA1A (R513A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR513A compressor — 1.4 kW cooling, 0.74 kW input, COP 1.94 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 2DB3F25KL-TFC (R407F Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407F compressor — 5.7 kW cooling, 3.26 kW input, COP 1.74 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRH038U2 (R410A scroll, 50 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 9.2 kW cooling, 3.35 kW input, COP 2.76 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh FH4527N-XG1A (R134a hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR134a compressor — 5.9 kW cooling, 2.33 kW input, COP 2.52 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 2DC3R53KL-TFD (R407A Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407A compressor — 18.3 kW cooling, 5.43 kW input, COP 3.37 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss HRM048U4 (R22 scroll, 50 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 11.5 kW cooling, 3.57 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AE4460Y-FZ3C (R513A hermetic, HBP, ASHRAE, 50 Hz) CatalogCompressorsTecumsehR513A compressor — 1.6 kW cooling, 0.66 kW input, COP 2.36 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 2DD3R63KL-TFC (R448A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR448A compressor — 10.1 kW cooling, 3.71 kW input, COP 2.74 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss LLZ015T2C (R455A scroll, 60 Hz) CatalogCompressorsDanfossR455A compressor — 4.7 kW cooling, 2.58 kW input, COP 1.81 at -30/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Tecumseh AG4573P-TZ1A (R449A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR449A compressor — 15.4 kW cooling, 6.62 kW input, COP 2.33 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 2DF3F16KL-TFC (R407F Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407F compressor — 3.7 kW cooling, 2.26 kW input, COP 1.66 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ015T4A (R134a scroll, 60 Hz, MT) CatalogCompressorsDanfossR134a compressor — 4.7 kW cooling, 1.51 kW input, COP 3.10 at the AHRI 7.2/54.4 °C rating point.Open in the builder
‹ Previous1…315316317318319…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet