Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 8,113–8,136 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Tecumseh AJ4492N-XA1A (R1234yf hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR1234yf compressor — 1.9 kW cooling, 1.00 kW input, COP 1.93 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 2YL3R73KE-TFC (R454C Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR454C compressor — 11.7 kW cooling, 4.18 kW input, COP 2.79 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRM054U4 (R22 scroll, 60 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 15.7 kW cooling, 4.62 kW input, COP 3.40 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh FH4538P-XC3A (R455A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR455A compressor — 7.9 kW cooling, 3.03 kW input, COP 2.60 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 3DA3F28KL-TFD (R407C Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407C compressor — 5.8 kW cooling, 3.62 kW input, COP 1.59 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss LLZ015T4B (R455A scroll, 60 Hz, LT) CatalogCompressorsDanfossR455A compressor — 4.7 kW cooling, 2.58 kW input, COP 1.81 at -30/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Tecumseh AJ4492N-XA1A (R1234yf hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR1234yf compressor — 2.3 kW cooling, 1.28 kW input, COP 1.84 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 3DADF28KL-TFC (R407F Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407F compressor — 6.6 kW cooling, 3.79 kW input, COP 1.73 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ015T4A (R449A scroll, 60 Hz, MT) CatalogCompressorsDanfossR449A compressor — 6.5 kW cooling, 2.46 kW input, COP 2.64 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh FH4538P-XG1A (R404A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR404A compressor — 7.7 kW cooling, 3.39 kW input, COP 2.28 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 3DADR10ML-TFC (R448A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR448A compressor — 17.8 kW cooling, 6.40 kW input, COP 2.79 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MT100-4 (R22 hermetic reciprocating, 60 Hz, A/C) CatalogCompressorsDanfossR22 compressor — 28.1 kW cooling, 9.58 kW input, COP 2.93 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh AJ4492N-XA1A (R134a hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR134a compressor — 2.1 kW cooling, 0.98 kW input, COP 2.10 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 3DB3F33KL-TFD (R407A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407A compressor — 8.3 kW cooling, 4.60 kW input, COP 1.81 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MTZ022-1 (R449A hermetic reciprocating, 60 Hz, MT) CatalogCompressorsDanfossR449A compressor — 5.8 kW cooling, 2.41 kW input, COP 2.41 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh FH4538P-XG1A (R404A hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR404A compressor — 9.0 kW cooling, 3.97 kW input, COP 2.26 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 3DBDF33KL-TFD (R407F Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407F compressor — 8.3 kW cooling, 4.60 kW input, COP 1.81 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss NTZ136-4B (R452A hermetic reciprocating, 50 Hz, LT) CatalogCompressorsDanfossR452A compressor — 2.8 kW cooling, 2.72 kW input, COP 1.02 at -35/45 °C (evaporating/condensing), inside its published envelope.Open in the builder
Tecumseh AJ4492N-XA1A (R134a hermetic, HBP, EN12900, 60 Hz) CatalogCompressorsTecumsehR134a compressor — 2.3 kW cooling, 1.16 kW input, COP 2.01 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 3DBDR12ML-TFC (R448A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR448A compressor — 21.4 kW cooling, 7.63 kW input, COP 2.81 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss PSH030-9 (R410A scroll, 60 Hz) CatalogCompressorsDanfossR410A compressor — 38.9 kW cooling, 13.03 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Tecumseh FH4538P-XG1A (R448A hermetic, HBP, EN12900, 50 Hz) CatalogCompressorsTecumsehR448A compressor — 8.2 kW cooling, 3.18 kW input, COP 2.57 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 3DF3F40KL-TFD (R407C Discus recip, 50 Hz, LD) CatalogCompressorsCopelandR407C compressor — 8.5 kW cooling, 5.21 kW input, COP 1.64 at -35/30 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss SH485-9K (R410A scroll, 60 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 140.6 kW cooling, 43.28 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.Open in the builder
‹ Previous1…337338339340341…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one