Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 8785–8808 of 10248
R449A compressor — 15.4 kW cooling, 6.62 kW input, COP 2.33 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 18.6 kW cooling, 8.53 kW input, COP 2.18 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 15.0 kW cooling, 6.91 kW input, COP 2.18 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 18.1 kW cooling, 8.90 kW input, COP 2.04 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 17.5 kW cooling, 7.51 kW input, COP 2.33 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 20.8 kW cooling, 9.33 kW input, COP 2.23 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 16.1 kW cooling, 7.97 kW input, COP 2.02 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 19.1 kW cooling, 9.90 kW input, COP 1.93 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 16.0 kW cooling, 6.96 kW input, COP 2.31 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 19.1 kW cooling, 8.65 kW input, COP 2.21 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 16.6 kW cooling, 7.38 kW input, COP 2.25 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 19.8 kW cooling, 9.17 kW input, COP 2.16 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 16.6 kW cooling, 7.38 kW input, COP 2.25 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 19.8 kW cooling, 9.17 kW input, COP 2.16 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 16.3 kW cooling, 7.71 kW input, COP 2.11 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 19.3 kW cooling, 9.58 kW input, COP 2.02 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 17.5 kW cooling, 7.48 kW input, COP 2.34 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 20.6 kW cooling, 9.46 kW input, COP 2.17 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 16.1 kW cooling, 7.94 kW input, COP 2.02 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 18.9 kW cooling, 10.04 kW input, COP 1.88 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 16.0 kW cooling, 6.93 kW input, COP 2.31 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 18.9 kW cooling, 8.77 kW input, COP 2.15 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 16.6 kW cooling, 7.36 kW input, COP 2.26 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 19.6 kW cooling, 9.31 kW input, COP 2.10 at the AHRI 7.2/54.4 °C rating point.
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one