Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 9385–9408 of 10248
R452A compressor — 2.2 kW cooling, 1.16 kW input, COP 1.92 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 2.3 kW cooling, 1.05 kW input, COP 2.23 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 2.3 kW cooling, 1.19 kW input, COP 1.91 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 2.2 kW cooling, 1.03 kW input, COP 2.17 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 2.3 kW cooling, 1.10 kW input, COP 2.13 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 2.3 kW cooling, 1.10 kW input, COP 2.13 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 2.3 kW cooling, 1.15 kW input, COP 2.00 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 2.3 kW cooling, 1.05 kW input, COP 2.21 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 2.2 kW cooling, 1.21 kW input, COP 1.86 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 2.2 kW cooling, 1.05 kW input, COP 2.11 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 2.3 kW cooling, 1.12 kW input, COP 2.08 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 2.3 kW cooling, 1.12 kW input, COP 2.08 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 2.3 kW cooling, 1.17 kW input, COP 1.95 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 3.1 kW cooling, 1.53 kW input, COP 2.05 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 2.5 kW cooling, 1.07 kW input, COP 2.36 at the AHRI 7.2/54.4 °C rating point.
R22 compressor — 3.0 kW cooling, 1.35 kW input, COP 2.19 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 2.3 kW cooling, 1.22 kW input, COP 1.86 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 2.7 kW cooling, 1.55 kW input, COP 1.73 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 2.2 kW cooling, 1.06 kW input, COP 2.11 at the AHRI 7.2/54.4 °C rating point.
R407C compressor — 2.7 kW cooling, 1.35 kW input, COP 1.97 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 2.3 kW cooling, 1.13 kW input, COP 2.08 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 2.8 kW cooling, 1.44 kW input, COP 1.94 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 2.3 kW cooling, 1.13 kW input, COP 2.08 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 2.8 kW cooling, 1.44 kW input, COP 1.94 at the AHRI 7.2/54.4 °C rating point.
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one