Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 9457–9480 of 10248
R452A compressor — 3.0 kW cooling, 1.84 kW input, COP 1.65 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 1.5 kW cooling, 0.68 kW input, COP 2.25 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 1.5 kW cooling, 0.71 kW input, COP 2.15 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 1.9 kW cooling, 0.91 kW input, COP 2.13 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 1.9 kW cooling, 0.84 kW input, COP 2.28 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 1.9 kW cooling, 0.83 kW input, COP 2.29 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 1.9 kW cooling, 0.87 kW input, COP 2.14 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 1.9 kW cooling, 0.91 kW input, COP 2.13 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 1.9 kW cooling, 0.84 kW input, COP 2.28 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 1.9 kW cooling, 0.83 kW input, COP 2.29 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 1.9 kW cooling, 0.87 kW input, COP 2.14 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 2.2 kW cooling, 1.10 kW input, COP 1.97 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 2.3 kW cooling, 1.06 kW input, COP 2.14 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 2.2 kW cooling, 1.02 kW input, COP 2.20 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 2.1 kW cooling, 1.05 kW input, COP 1.99 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 2.2 kW cooling, 1.10 kW input, COP 1.97 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 2.3 kW cooling, 1.06 kW input, COP 2.14 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 2.2 kW cooling, 1.02 kW input, COP 2.20 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 2.1 kW cooling, 1.05 kW input, COP 1.99 at the AHRI 7.2/54.4 °C rating point.
R290 compressor — 1.7 kW cooling, 0.75 kW input, COP 2.30 at the AHRI 7.2/54.4 °C rating point.
R290 compressor — 1.9 kW cooling, 0.64 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point.
R290 compressor — 1.9 kW cooling, 0.64 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point.
R290 compressor — 2.1 kW cooling, 0.67 kW input, COP 3.18 at the AHRI 7.2/54.4 °C rating point.
R290 compressor — 2.0 kW cooling, 0.90 kW input, COP 2.26 at the AHRI 7.2/54.4 °C rating point.
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one