Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 9793–9816 of 10248
R455A compressor — 6.3 kW cooling, 2.25 kW input, COP 2.81 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 6.0 kW cooling, 2.63 kW input, COP 2.29 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 7.3 kW cooling, 3.15 kW input, COP 2.30 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 6.2 kW cooling, 2.44 kW input, COP 2.56 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 7.5 kW cooling, 2.95 kW input, COP 2.55 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 6.1 kW cooling, 2.55 kW input, COP 2.39 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 7.4 kW cooling, 3.09 kW input, COP 2.38 at the AHRI 7.2/54.4 °C rating point.
R454C compressor — 5.7 kW cooling, 2.05 kW input, COP 2.76 at the AHRI 7.2/54.4 °C rating point.
R454C compressor — 6.9 kW cooling, 2.50 kW input, COP 2.76 at the AHRI 7.2/54.4 °C rating point.
R455A compressor — 6.0 kW cooling, 2.22 kW input, COP 2.70 at the AHRI 7.2/54.4 °C rating point.
R455A compressor — 7.3 kW cooling, 2.72 kW input, COP 2.70 at the AHRI 7.2/54.4 °C rating point.
R455A compressor — 6.1 kW cooling, 2.45 kW input, COP 2.48 at the AHRI 7.2/54.4 °C rating point.
R455A compressor — 7.3 kW cooling, 3.00 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 6.4 kW cooling, 2.67 kW input, COP 2.38 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 7.4 kW cooling, 3.24 kW input, COP 2.28 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 6.6 kW cooling, 2.48 kW input, COP 2.66 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 7.6 kW cooling, 3.00 kW input, COP 2.55 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 6.6 kW cooling, 2.48 kW input, COP 2.66 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 7.6 kW cooling, 3.00 kW input, COP 2.55 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 6.4 kW cooling, 2.59 kW input, COP 2.48 at the AHRI 7.2/54.4 °C rating point.
R452A compressor — 7.5 kW cooling, 3.14 kW input, COP 2.38 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 6.3 kW cooling, 2.67 kW input, COP 2.34 at the AHRI 7.2/54.4 °C rating point.
R448A compressor — 6.5 kW cooling, 2.48 kW input, COP 2.62 at the AHRI 7.2/54.4 °C rating point.
R449A compressor — 6.5 kW cooling, 2.48 kW input, COP 2.62 at the AHRI 7.2/54.4 °C rating point.
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one