Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, exchangers and recovery cores — published by the manufacturers themselves and selectable directly inside the builder.
Showing 9961–9984 of 10248
R134a compressor — 0.2 kW cooling, 0.12 kW input, COP 1.99 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 0.3 kW cooling, 0.14 kW input, COP 1.99 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 0.2 kW cooling, 0.13 kW input, COP 1.91 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 0.3 kW cooling, 0.15 kW input, COP 1.88 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 0.3 kW cooling, 0.14 kW input, COP 2.07 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 0.3 kW cooling, 0.15 kW input, COP 2.00 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 0.5 kW cooling, 0.24 kW input, COP 1.92 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 0.5 kW cooling, 0.25 kW input, COP 1.85 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 0.4 kW cooling, 0.18 kW input, COP 2.12 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 0.5 kW cooling, 0.22 kW input, COP 2.11 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 0.4 kW cooling, 0.19 kW input, COP 2.04 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 0.5 kW cooling, 0.23 kW input, COP 1.99 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 0.5 kW cooling, 0.26 kW input, COP 1.78 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 0.5 kW cooling, 0.27 kW input, COP 1.71 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 0.4 kW cooling, 0.19 kW input, COP 2.10 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 0.5 kW cooling, 0.24 kW input, COP 2.02 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 0.4 kW cooling, 0.20 kW input, COP 2.01 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 0.5 kW cooling, 0.25 kW input, COP 1.94 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 0.6 kW cooling, 0.35 kW input, COP 1.84 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 0.6 kW cooling, 0.36 kW input, COP 1.65 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 0.5 kW cooling, 0.29 kW input, COP 1.86 at the AHRI 7.2/54.4 °C rating point.
R134a compressor — 0.6 kW cooling, 0.32 kW input, COP 1.94 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 0.5 kW cooling, 0.30 kW input, COP 1.78 at the AHRI 7.2/54.4 °C rating point.
R513A compressor — 0.6 kW cooling, 0.34 kW input, COP 1.81 at the AHRI 7.2/54.4 °C rating point.
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one