Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 9,961–9,984 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Danfoss LLZ033T2 (R404A scroll, 60 Hz, LT) CatalogCompressorsDanfossR404A compressor — 9.4 kW cooling, 5.65 kW input, COP 1.67 at -35/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Copeland 4DANF47KL-TSK (R407F Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407F compressor — 11.0 kW cooling, 6.43 kW input, COP 1.71 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ019T2A (R452A scroll, 60 Hz, MT) CatalogCompressorsDanfossR452A compressor — 8.2 kW cooling, 3.22 kW input, COP 2.55 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 4DANR18ML-TSK (R449A Discus recip, 50 Hz, MD) CatalogCompressorsCopelandR449A compressor — 25.8 kW cooling, 9.04 kW input, COP 2.86 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MTZ028-4 (R404A hermetic reciprocating, 50 Hz, MT) CatalogCompressorsDanfossR404A compressor — 6.1 kW cooling, 2.81 kW input, COP 2.19 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 4DAXF47KL-TSK (R407F Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407F compressor — 11.0 kW cooling, 6.43 kW input, COP 1.71 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss PSH105-8 (R410A scroll, 50 Hz) CatalogCompressorsDanfossR410A compressor — 110.2 kW cooling, 36.21 kW input, COP 3.04 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 4DAXR18ML-TSK (R449A Discus recip, 50 Hz, MD) CatalogCompressorsCopelandR449A compressor — 25.8 kW cooling, 9.04 kW input, COP 2.86 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss SZ185W7 (R134a scroll, 60 Hz, A/C) CatalogCompressorsDanfossR134a compressor — 36.6 kW cooling, 11.10 kW input, COP 3.30 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 4DENF47KL-TSK (R407F Discus recip, 50 Hz, LD) CatalogCompressorsCopelandR407F compressor — 9.2 kW cooling, 5.36 kW input, COP 1.71 at -35/30 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss HRH054U4A (R454B scroll, 60 Hz) CatalogCompressorsDanfossR454B compressor — 15.2 kW cooling, 4.79 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 4DENR18ML-TSK (R407F Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR407F compressor — 30.1 kW cooling, 10.71 kW input, COP 2.81 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss LLZ033T4 (R404A scroll, 50 Hz, LT) CatalogCompressorsDanfossR404A compressor — 7.8 kW cooling, 4.98 kW input, COP 1.56 at -35/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Copeland 4DHNR22ML-TSK (R407F Discus recip, 50 Hz, AC) CatalogCompressorsCopelandR407F compressor — 66.7 kW cooling, 21.05 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Danfoss MLZ019T2A (R513A scroll, 50 Hz, MT) CatalogCompressorsDanfossR513A compressor — 4.7 kW cooling, 1.70 kW input, COP 2.74 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 4DHXR22ML-TSK (R407F Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407F compressor — 80.0 kW cooling, 25.26 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss MTZ028-4 (R404A hermetic reciprocating, 60 Hz, MT) CatalogCompressorsDanfossR404A compressor — 7.4 kW cooling, 3.44 kW input, COP 2.16 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 4DJXR28ML-TSK (R407F Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407F compressor — 94.4 kW cooling, 30.98 kW input, COP 3.05 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss SZ185W7 (R407C scroll, 50 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 43.1 kW cooling, 13.62 kW input, COP 3.16 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 6DHNR35ML-TSK (R448A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR448A compressor — 57.8 kW cooling, 20.52 kW input, COP 2.82 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRH054U4B (R410A scroll, 50 Hz) CatalogCompressorsDanfossR410A compressor — 11.8 kW cooling, 4.40 kW input, COP 2.68 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 6DJNR40ML-TSN (R407F Discus recip, 50 Hz, MD) CatalogCompressorsCopelandR407F compressor — 58.7 kW cooling, 21.88 kW input, COP 2.68 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss LLZ033T4 (R404A scroll, 60 Hz, LT) CatalogCompressorsDanfossR404A compressor — 9.4 kW cooling, 5.65 kW input, COP 1.67 at -35/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Copeland 6DUNF13ML-AWD (R404A Discus recip, 50 Hz, LD) CatalogCompressorsCopelandR404A compressor — 34.1 kW cooling, 18.60 kW input, COP 1.83 at -35/30 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
‹ Previous1…414415416417418…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory