Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 10,081–10,104 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Danfoss HRH056U1 (R410A scroll, 60 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 16.7 kW cooling, 5.39 kW input, COP 3.09 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 2DA3R89KL-TFD (R407C Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407C compressor — 30.3 kW cooling, 9.47 kW input, COP 3.20 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss LLZ034T2C (R404A scroll, 60 Hz, LT) CatalogCompressorsDanfossR404A compressor — 9.7 kW cooling, 5.43 kW input, COP 1.78 at -35/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Copeland 2DL3R78KL-TFD (R407C Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407C compressor — 27.0 kW cooling, 8.26 kW input, COP 3.27 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss MLZ019T2C (R449A scroll, 60 Hz, MT) CatalogCompressorsDanfossR449A compressor — 8.5 kW cooling, 3.12 kW input, COP 2.72 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 3DA3R10ML-TFD (R407A Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407A compressor — 35.9 kW cooling, 10.95 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss MTZ028-4 (R452A hermetic reciprocating, 50 Hz, MT) CatalogCompressorsDanfossR452A compressor — 5.8 kW cooling, 2.65 kW input, COP 2.17 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 3DB3R12ME-TFD (R407C Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407C compressor — 41.0 kW cooling, 12.28 kW input, COP 3.34 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss SZ240-9 (R407C scroll, 60 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 71.1 kW cooling, 22.66 kW input, COP 3.14 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 3DF3R15ME-TFD (R448A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR448A compressor — 24.6 kW cooling, 8.71 kW input, COP 2.83 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRH056U2 (R410A scroll, 50 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 13.8 kW cooling, 4.58 kW input, COP 3.02 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 3DS3R17ME-TFD (R407F Discus recip, 50 Hz, MD) CatalogCompressorsCopelandR407F compressor — 23.0 kW cooling, 8.45 kW input, COP 2.72 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss LLZ034T2C (R448A scroll, 50 Hz, LT) CatalogCompressorsDanfossR448A compressor — 6.1 kW cooling, 4.02 kW input, COP 1.52 at -35/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Copeland 3PA3R85KL-TFD (R410A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR410A compressor — 22.4 kW cooling, 8.08 kW input, COP 2.77 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ019T2C (R452A scroll, 50 Hz, MT) CatalogCompressorsDanfossR452A compressor — 6.8 kW cooling, 2.71 kW input, COP 2.51 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 3YF4S87KL-TFD (R454C Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR454C compressor — 19.0 kW cooling, 7.03 kW input, COP 2.71 at -20/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MTZ028-4 (R452A hermetic reciprocating, 60 Hz, MT) CatalogCompressorsDanfossR452A compressor — 7.2 kW cooling, 3.18 kW input, COP 2.25 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 4DANF47KL-TSK (R448A Discus recip, 50 Hz, LD) CatalogCompressorsCopelandR448A compressor — 9.6 kW cooling, 5.64 kW input, COP 1.71 at -35/30 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss SZ300-3 (R134a scroll, 60 Hz, A/C) CatalogCompressorsDanfossR134a compressor — 60.6 kW cooling, 19.61 kW input, COP 3.09 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 4DANR18ML-TSK (R449A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR449A compressor — 31.0 kW cooling, 10.85 kW input, COP 2.86 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss HRH056U2 (R410A scroll, 60 Hz, A/C) CatalogCompressorsDanfossR410A compressor — 16.7 kW cooling, 5.36 kW input, COP 3.11 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 4DAXF47KL-TSK (R448A Discus recip, 50 Hz, LD) CatalogCompressorsCopelandR448A compressor — 9.6 kW cooling, 5.64 kW input, COP 1.71 at -35/30 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss LLZ034T2C (R448A scroll, 60 Hz, LT) CatalogCompressorsDanfossR448A compressor — 7.9 kW cooling, 4.81 kW input, COP 1.65 at -35/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Copeland 4DAXR18ML-TSK (R449A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR449A compressor — 31.0 kW cooling, 10.85 kW input, COP 2.86 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
‹ Previous1…419420421422423…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one