Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 10,321–10,344 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Danfoss MLZ019T4A (R407F scroll, 50 Hz, MT) CatalogCompressorsDanfossR407F compressor — 7.6 kW cooling, 2.80 kW input, COP 2.73 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 3DA8F28KE-TFD (R407A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407A compressor — 6.6 kW cooling, 3.79 kW input, COP 1.73 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MTZ028-9 (R448A hermetic reciprocating, 60 Hz, MT) CatalogCompressorsDanfossR448A compressor — 7.2 kW cooling, 2.98 kW input, COP 2.40 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 3DB3R12ML-TFC (R448A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR448A compressor — 21.4 kW cooling, 7.63 kW input, COP 2.81 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ019T4A (R407F scroll, 60 Hz, MT) CatalogCompressorsDanfossR407F compressor — 9.4 kW cooling, 3.24 kW input, COP 2.90 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 3DF3R15ML-TFD (R407C Discus recip, 60 Hz, AC) CatalogCompressorsCopelandR407C compressor — 47.8 kW cooling, 15.13 kW input, COP 3.16 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss MTZ028-9 (R449A hermetic reciprocating, 60 Hz, MT) CatalogCompressorsDanfossR449A compressor — 7.2 kW cooling, 2.98 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 3DS3R17ME-TFD (R448A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR448A compressor — 28.7 kW cooling, 10.26 kW input, COP 2.80 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ019T4A (R448A scroll, 50 Hz, MT) CatalogCompressorsDanfossR448A compressor — 7.1 kW cooling, 2.72 kW input, COP 2.60 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 3YF4S87KL-TFD (R455A Discus recip, 60 Hz, MD) CatalogCompressorsCopelandR455A compressor — 20.4 kW cooling, 7.55 kW input, COP 2.71 at -20/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MTZ028-9 (R452A hermetic reciprocating, 60 Hz, MT) CatalogCompressorsDanfossR452A compressor — 7.2 kW cooling, 3.18 kW input, COP 2.25 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 4DANF47KL-TSK (R449A Discus recip, 50 Hz, LD) CatalogCompressorsCopelandR449A compressor — 9.6 kW cooling, 5.64 kW input, COP 1.71 at -35/30 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MLZ019T4A (R448A scroll, 60 Hz, MT) CatalogCompressorsDanfossR448A compressor — 8.5 kW cooling, 3.12 kW input, COP 2.72 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 4DAXF47KL-TSK (R449A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR449A compressor — 11.6 kW cooling, 6.77 kW input, COP 1.71 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MTZ028-9 (R513A hermetic reciprocating, 60 Hz, A/C) CatalogCompressorsDanfossR513A compressor — 5.0 kW cooling, 2.02 kW input, COP 2.48 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 4DENF47KL-TSK (R448A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR448A compressor — 11.6 kW cooling, 6.77 kW input, COP 1.71 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ019T4A (R449A scroll, 50 Hz, MT) CatalogCompressorsDanfossR449A compressor — 7.1 kW cooling, 2.72 kW input, COP 2.60 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 4DENR18ML-TSK (R449A Discus recip, 50 Hz, MD) CatalogCompressorsCopelandR449A compressor — 25.8 kW cooling, 9.04 kW input, COP 2.86 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MTZ032-1 (R134a hermetic reciprocating, 60 Hz, A/C) CatalogCompressorsDanfossR134a compressor — 5.3 kW cooling, 2.17 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 6DUNF13ML-AWD (R407A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407A compressor — 30.3 kW cooling, 18.02 kW input, COP 1.68 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ019T4A (R449A scroll, 60 Hz, MT) CatalogCompressorsDanfossR449A compressor — 8.5 kW cooling, 3.12 kW input, COP 2.72 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 6DUNR49ME-TSE (R507 Discus recip, 50 Hz, MD) CatalogCompressorsCopelandR507 compressor — 90.3 kW cooling, 36.23 kW input, COP 2.49 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MTZ032-1 (R404A hermetic reciprocating, 60 Hz, MT) CatalogCompressorsDanfossR404A compressor — 8.2 kW cooling, 3.84 kW input, COP 2.14 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland 6DUXF13ML-AWD (R407A Discus recip, 60 Hz, LD) CatalogCompressorsCopelandR407A compressor — 30.3 kW cooling, 18.02 kW input, COP 1.68 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
‹ Previous1…429430431432433…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one