Published components
Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.
Showing 10,609–10,632 of 15,410
| Name | Type | Manufacturer | Rating | Markets | Open in the builder |
|---|---|---|---|---|---|
| Danfoss MLZ021T1 (R22 scroll, 60 Hz, MT) Catalog | Compressors | Danfoss | R22 compressor — 9.2 kW cooling, 3.14 kW input, COP 2.94 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Copeland 6DUNF13ML-AWD (R407F Discus recip, 50 Hz, LD) Catalog | Compressors | Copeland | R407F compressor — 25.3 kW cooling, 15.02 kW input, COP 1.68 at -35/30 °C (evaporating/condensing), inside its published envelope. | EU, APAC | Open in the builder |
| Danfoss MTZ032-7 (R407A hermetic reciprocating, 50 Hz, MT) Catalog | Compressors | Danfoss | R407A compressor — 7.0 kW cooling, 2.82 kW input, COP 2.47 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Copeland 6DUNR49ML-AWD (R22 Discus recip, 60 Hz, MD) Catalog | Compressors | Copeland | R22 compressor — 80.8 kW cooling, 29.51 kW input, COP 2.74 at -15/35 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss MLZ021T1 (R404A scroll, 60 Hz, MT) Catalog | Compressors | Danfoss | R404A compressor — 4.6 kW cooling, 2.22 kW input, COP 2.07 at -20/35 °C (evaporating/condensing), inside its published envelope. | Open in the builder | |
| Copeland 6DUXF13ML-AWD (R407F Discus recip, 50 Hz, LD) Catalog | Compressors | Copeland | R407F compressor — 25.3 kW cooling, 15.02 kW input, COP 1.68 at -35/30 °C (evaporating/condensing), inside its published envelope. | EU, APAC | Open in the builder |
| Danfoss MTZ032-7 (R407A hermetic reciprocating, 60 Hz, MT) Catalog | Compressors | Danfoss | R407A compressor — 8.4 kW cooling, 3.38 kW input, COP 2.47 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Copeland 6DUXR49ML-AWD (R22 Discus recip, 60 Hz, MD) Catalog | Compressors | Copeland | R22 compressor — 80.8 kW cooling, 29.51 kW input, COP 2.74 at -15/35 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss MLZ021T1 (R407C scroll, 60 Hz, MT) Catalog | Compressors | Danfoss | R407C compressor — 9.6 kW cooling, 2.99 kW input, COP 3.20 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Copeland 6DVNF13ML-AWD (R448A Discus recip, 60 Hz, LD) Catalog | Compressors | Copeland | R448A compressor — 31.9 kW cooling, 18.29 kW input, COP 1.74 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss MTZ032-7 (R407C hermetic reciprocating, 50 Hz, HT) Catalog | Compressors | Danfoss | R407C compressor — 6.7 kW cooling, 2.65 kW input, COP 2.52 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Copeland 6DVNR49ML-AWD (R22 Discus recip, 60 Hz, MD) Catalog | Compressors | Copeland | R22 compressor — 80.8 kW cooling, 29.51 kW input, COP 2.74 at -15/35 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss MLZ021T1A (R134a scroll, 60 Hz, MT) Catalog | Compressors | Danfoss | R134a compressor — 6.2 kW cooling, 2.25 kW input, COP 2.74 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Copeland 6DVXF13ML-AWD (R448A Discus recip, 60 Hz, LD) Catalog | Compressors | Copeland | R448A compressor — 31.9 kW cooling, 18.29 kW input, COP 1.74 at -35/30 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss MTZ032-7 (R407C hermetic reciprocating, 60 Hz, A/C) Catalog | Compressors | Danfoss | R407C compressor — 9.0 kW cooling, 3.20 kW input, COP 2.81 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Copeland 6DVXR49ML-AWD (R22 Discus recip, 60 Hz, MD) Catalog | Compressors | Copeland | R22 compressor — 80.8 kW cooling, 29.51 kW input, COP 2.74 at -15/35 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss MLZ021T1A (R22 scroll, 60 Hz, MT) Catalog | Compressors | Danfoss | R22 compressor — 9.2 kW cooling, 3.14 kW input, COP 2.94 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Copeland 6DZNR49ML-AWD (R407F Discus recip, 60 Hz, MD) Catalog | Compressors | Copeland | R407F compressor — 80.4 kW cooling, 29.86 kW input, COP 2.69 at -15/35 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss MTZ032-7 (R407F hermetic reciprocating, 50 Hz, MT) Catalog | Compressors | Danfoss | R407F compressor — 7.5 kW cooling, 2.98 kW input, COP 2.52 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Copeland AFE16C4U-CAA (R290 hermetic recip, 60 Hz, LA) Catalog | Compressors | Copeland | R290 compressor — 0.46 kW cooling, 0.41 kW input, COP 1.13 at -30/40 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
| Danfoss MLZ021T1A (R404A scroll, 60 Hz, MT) Catalog | Compressors | Danfoss | R404A compressor — 8.8 kW cooling, 3.45 kW input, COP 2.54 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Copeland ARE40C4E-IAA (R513A hermetic recip, 60 Hz, HT) Catalog | Compressors | Copeland | R513A compressor — 1.2 kW cooling, 0.68 kW input, COP 1.73 at the AHRI 7.2/54.4 °C rating point. | NA | Open in the builder |
| Danfoss MTZ032-7 (R407F hermetic reciprocating, 60 Hz, MT) Catalog | Compressors | Danfoss | R407F compressor — 9.0 kW cooling, 3.58 kW input, COP 2.52 at the AHRI 7.2/54.4 °C rating point. | Open in the builder | |
| Copeland ASE20C5E-CAA (R404A hermetic recip, 60 Hz, MT) Catalog | Compressors | Copeland | R404A compressor — 0.37 kW cooling, 0.31 kW input, COP 1.20 at -20/45 °C (evaporating/condensing), inside its published envelope. | NA | Open in the builder |
Refrigerant circuit
- Compressors — 14,438
Heat exchangers and recovery
- Coils — 1
- Pipe-in-pipe exchangers — 21
- Recovery cores — 76
- Heat pipes — 3
Fans and air movement
- Fans — 344
Pumps and hydronics
- Pumps — 260
Heating and humidity
- Heaters — 122
- Radiators and emitters — 113
- Humidifiers — 27
Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory
Publishing here
Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one