Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 12,337–12,360 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Danfoss MLZ030T4B (R407A scroll, 60 Hz, MT) CatalogCompressorsDanfossR407A compressor — 13.7 kW cooling, 4.48 kW input, COP 3.07 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZF06KAE-TF5 (R448A scroll, 60 Hz, LL) CatalogCompressorsCopelandR448A compressor — 1.4 kW cooling, 1.25 kW input, COP 1.12 at -35/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MTZ064-9 (R513A hermetic reciprocating, 60 Hz, A/C) CatalogCompressorsDanfossR513A compressor — 11.2 kW cooling, 4.33 kW input, COP 2.59 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZFH09KAE-TF5 (R407C scroll, 50 Hz, LT) CatalogCompressorsCopelandR407C compressor — 1.4 kW cooling, 1.37 kW input, COP 1.05 at -35/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MLZ030T4B (R407C scroll, 50 Hz, MT) CatalogCompressorsDanfossR407C compressor — 12.1 kW cooling, 3.83 kW input, COP 3.17 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZP296KCE-TE5 (R410A scroll, 50 Hz, AC) CatalogCompressorsCopelandR410A compressor — 71.3 kW cooling, 21.99 kW input, COP 3.24 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Danfoss MTZ072-3 (R134a hermetic reciprocating, 60 Hz, A/C) CatalogCompressorsDanfossR134a compressor — 12.3 kW cooling, 4.87 kW input, COP 2.53 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZR22KTE-TFD (R407C scroll, 60 Hz, AC) CatalogCompressorsCopelandR407C compressor — 6.1 kW cooling, 2.11 kW input, COP 2.89 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss MLZ030T4B (R407C scroll, 60 Hz, MT) CatalogCompressorsDanfossR407C compressor — 14.4 kW cooling, 4.46 kW input, COP 3.23 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZS15KAE-TF5 (R407A scroll, 50 Hz, EM) CatalogCompressorsCopelandR407A compressor — 1.9 kW cooling, 1.30 kW input, COP 1.46 at -25/40 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MTZ072-3 (R404A hermetic reciprocating, 60 Hz, MT) CatalogCompressorsDanfossR404A compressor — 19.3 kW cooling, 8.34 kW input, COP 2.32 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ZW61KAE-TFP (R407C scroll, 50 Hz, HP) CatalogCompressorsCopelandR407C compressor — 18.8 kW cooling, 4.63 kW input, COP 4.06 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Danfoss MLZ030T4B (R407F scroll, 50 Hz, MT) CatalogCompressorsDanfossR407F compressor — 12.0 kW cooling, 4.01 kW input, COP 2.99 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland ASE43C7U-IFZ (R290 hermetic recip, 50 Hz, EM) CatalogCompressorsCopelandR290 compressor — 0.43 kW cooling, 0.31 kW input, COP 1.41 at -30/40 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MTZ072-3 (R407A hermetic reciprocating, 60 Hz, MT) CatalogCompressorsDanfossR407A compressor — 19.0 kW cooling, 7.22 kW input, COP 2.63 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland CR42K6E-PFV (R22 hermetic recip, 60 Hz, AC) CatalogCompressorsCopelandR22 compressor — 11.6 kW cooling, 3.56 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss MLZ030T4B (R407F scroll, 60 Hz, MT) CatalogCompressorsDanfossR407F compressor — 14.8 kW cooling, 4.80 kW input, COP 3.09 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland YB21K1E-TFD (R407C scroll, 60 Hz, MT) CatalogCompressorsCopelandR407C compressor — 5.8 kW cooling, 2.24 kW input, COP 2.60 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MTZ072-3 (R407C hermetic reciprocating, 60 Hz, A/C) CatalogCompressorsDanfossR407C compressor — 20.8 kW cooling, 7.30 kW input, COP 2.85 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland YBD31K1E-TFD (R407C scroll, 60 Hz, MT) CatalogCompressorsCopelandR407C compressor — 8.2 kW cooling, 3.11 kW input, COP 2.65 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss MLZ030T4B (R448A scroll, 50 Hz, MT) CatalogCompressorsDanfossR448A compressor — 11.1 kW cooling, 4.04 kW input, COP 2.74 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland YF06KAE-TF5 (R454C scroll, 50 Hz, LT) CatalogCompressorsCopelandR454C compressor — 1.1 kW cooling, 0.96 kW input, COP 1.11 at -35/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MTZ072-3 (R407F hermetic reciprocating, 60 Hz, MT) CatalogCompressorsDanfossR407F compressor — 20.5 kW cooling, 7.63 kW input, COP 2.68 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Copeland YFH07KAU-TF5 (R290 scroll, 50 Hz, LT) CatalogCompressorsCopelandR290 compressor — 1.3 kW cooling, 0.95 kW input, COP 1.39 at -35/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
‹ Previous1…513514515516517…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one