Published components

Compressors with AHRI 540 maps, coils with real geometry, fans, pumps, evaporative media, heaters, humidifiers, radiators, exchangers and recovery cores — the parts the builder models, published by the manufacturers themselves and selectable directly inside the builder, where each one solves on its own published figures.

Suppliers 46Systems 3,474Components 15,410Accessories 3

Showing 14,761–14,784 of 15,410

NameTypeManufacturerRatingMarketsOpen in the builder
Copeland YB68KAE-TFD (R452A scroll, 60 Hz, MT) CatalogCompressorsCopelandR452A compressor — 18.4 kW cooling, 8.44 kW input, COP 2.18 at -15/40 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland YF13KAE-PFV (R507 scroll, 50 Hz, LL) CatalogCompressorsCopelandR507 compressor — 3.8 kW cooling, 2.76 kW input, COP 1.38 at -35/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZB220KQE-TRD (R407C scroll, 50 Hz, MT) CatalogCompressorsCopelandR407C compressor — 81.9 kW cooling, 27.04 kW input, COP 3.03 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Copeland ZBD76KCE-TF5 (R448A scroll, 50 Hz, MT) CatalogCompressorsCopelandR448A compressor — 15.5 kW cooling, 6.20 kW input, COP 2.50 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF13K4E-TF5 (R134A scroll, 60 Hz, HT) CatalogCompressorsCopelandR134a compressor — 8.9 kW cooling, 3.10 kW input, COP 2.88 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland ZR61KE-TFD (R22 scroll, 50 Hz, AC) CatalogCompressorsCopelandR22 compressor — 14.9 kW cooling, 4.47 kW input, COP 3.34 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Copeland ZS38K4E-TF5 (R407C scroll, 60 Hz, EM) CatalogCompressorsCopelandR407C compressor — 5.5 kW cooling, 3.06 kW input, COP 1.78 at -25/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland YB68KAE-TFD (R513A scroll, 50 Hz, HT) CatalogCompressorsCopelandR513A compressor — 18.0 kW cooling, 6.53 kW input, COP 2.76 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Copeland YF13KAE-TF5 (R454A scroll, 50 Hz, LL) CatalogCompressorsCopelandR454A compressor — 3.4 kW cooling, 2.64 kW input, COP 1.27 at -35/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZB220KQE-TWD (R404A scroll, 50 Hz, MT) CatalogCompressorsCopelandR404A compressor — 81.1 kW cooling, 31.00 kW input, COP 2.62 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Copeland ZBD76KCE-TF5 (R448A scroll, 60 Hz, MT) CatalogCompressorsCopelandR448A compressor — 18.6 kW cooling, 7.44 kW input, COP 2.50 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZF13K4E-TF5 (R404A scroll, 50 Hz, LL) CatalogCompressorsCopelandR404A compressor — 4.1 kW cooling, 1.97 kW input, COP 2.09 at -30/25 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZR61KE-TFD (R22 scroll, 60 Hz, AC) CatalogCompressorsCopelandR22 compressor — 18.3 kW cooling, 5.38 kW input, COP 3.40 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland ZS38K4E-TF5 (R448A scroll, 50 Hz, EM) CatalogCompressorsCopelandR448A compressor — 5.0 kW cooling, 2.76 kW input, COP 1.82 at -25/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland YB68KAE-TFD (R513A scroll, 60 Hz, HT) CatalogCompressorsCopelandR513A compressor — 21.6 kW cooling, 7.83 kW input, COP 2.76 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Copeland YF13KAE-TF5 (R454A scroll, 60 Hz, LL) CatalogCompressorsCopelandR454A compressor — 4.0 kW cooling, 3.17 kW input, COP 1.27 at -35/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZB220KQE-TWD (R404A scroll, 60 Hz, MT) CatalogCompressorsCopelandR404A compressor — 97.5 kW cooling, 37.48 kW input, COP 2.60 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
Copeland ZBD76KCE-TF5 (R449A scroll, 50 Hz, MT) CatalogCompressorsCopelandR449A compressor — 15.5 kW cooling, 6.20 kW input, COP 2.50 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZF13K4E-TF5 (R404A scroll, 60 Hz, LL) CatalogCompressorsCopelandR404A compressor — 4.9 kW cooling, 2.37 kW input, COP 2.09 at -30/25 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland ZR61KEE-TFM (R407C scroll, 50 Hz, AC) CatalogCompressorsCopelandR407C compressor — 14.7 kW cooling, 4.55 kW input, COP 3.22 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Copeland ZS38K4E-TF5 (R448A scroll, 60 Hz, EM) CatalogCompressorsCopelandR448A compressor — 6.0 kW cooling, 3.31 kW input, COP 1.82 at -25/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Copeland YB81K1G-TFD (R290 scroll, 50 Hz, MT) CatalogCompressorsCopelandR290 compressor — 29.7 kW cooling, 9.77 kW input, COP 3.04 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Copeland YF13KAE-TF5 (R454C scroll, 50 Hz, LL) CatalogCompressorsCopelandR454C compressor — 2.8 kW cooling, 2.15 kW input, COP 1.33 at -35/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Copeland ZB220KQE-TWD (R407A scroll, 50 Hz, MT) CatalogCompressorsCopelandR407A compressor — 85.1 kW cooling, 29.70 kW input, COP 2.86 at the AHRI 7.2/54.4 °C rating point.APACOpen in the builder
‹ Previous1…614615616617618…643Next ›

Refrigerant circuit

Heat exchangers and recovery

Fans and air movement

Pumps and hydronics

Heating and humidity

Evaporative cooling and heat rejection

Cooling towers — none listed yet

Complete machines — air handlers, rooftops, splits, chillers, fan coils, cooling towers — are systems: the systems directory

Publishing here

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors Twelve manufacturers' ranges are already in the catalog from their published data — the brands, and how to claim one