Flat: radiators, 12 kW at ΔT 50

by HVAC Builder

Open this system in HVAC Builder Load it into the 3D builder, adjust it to your project, and solve it against your own climate — or drop it into a building model and simulate a full year.

One dwelling's radiators, fed from a plant across a water coupling. It is a single component and that is the point: a radiator is rated, not modelled — the EN 442 output at 75/65/20 °C and a characteristic exponent, with no geometry. Twelve kilowatts at that rating carries a 2.6 kW flat on 40 °C water, which is the low flow temperature a heat pump wants. That four-to-one multiple is the whole cost of a low-temperature retrofit: the same flat on a 70 °C boiler needs a third of the radiator. Published as an example; the figures below are solved from this model.

Example2–4 kW heatingEU

Example system. Published by HVAC Builder to show suppliers what their own page looks like. There is no company behind it and it is not a product offer — the specification is generic and the performance is solved from the model on this page.

Design-point performance

2.6 kWheating
-0.0 kWelectrical power

Solved from this example's own model each time the page loads — the same numbers a supplier's page shows for their machine.

Component schedule

ComponentKindDuty
Radiators (12 kW at ΔT 50)emitter-2.6 kW