677 listing(s) in HVAC Builder's catalog from Baltimore Aircoil's published data and 6 system(s) modelled on it, selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; Baltimore Aircoil has not claimed it.
Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page
Built in this model on the maker's own published data — not verified by Baltimore Aircoil. Each page names the document it was read from and what the model was held to.
| Baltimore Aircoil VT0-12-E cooling tower (12 tons, 53 kW) — modelled | Baltimore Aircoil Product & Application Handbook volume VI, Series V engineering data — the model's own row (nominal tonnage, airflow in CFM, fan motor, dimensions) and the sheet's own rating note: a nominal ton is 3 USGPM of water cooled from 95 °F to 85 °F at a 78 °F entering wet-bulb temperature (docs/bac-source.json) |
| Baltimore Aircoil FXT-0709B-J cooling tower (130 tons, 571 kW) — modelled | Baltimore Aircoil Product & Application Handbook volume VI, FXT engineering data — the model's own row (nominal tonnage, airflow in CFM, fan motor, dimensions) and the sheet's own rating note: a nominal ton is 3 USGPM of water cooled from 95 °F to 85 °F at a 78 °F entering wet-bulb temperature (docs/bac-source.json) |
| Baltimore Aircoil Series 1500 S15E-1285-09LN cooling tower (253 tons, 1.1 MW) — modelled | Baltimore Aircoil Product & Application Handbook volume VI, Series 1500 engineering data — the model's own row (nominal tonnage, airflow in CFM, fan motor, dimensions) and the sheet's own rating note: a nominal ton is 3 USGPM of water cooled from 95 °F to 85 °F at a 78 °F entering wet-bulb temperature (docs/bac-source.json) |
| Baltimore Aircoil VT1-600-P cooling tower (600 tons, 2.6 MW) — modelled | Baltimore Aircoil Product & Application Handbook volume VI, Series V engineering data — the model's own row (nominal tonnage, airflow in CFM, fan motor, dimensions) and the sheet's own rating note: a nominal ton is 3 USGPM of water cooled from 95 °F to 85 °F at a 78 °F entering wet-bulb temperature (docs/bac-source.json) |
| Baltimore Aircoil Series 3000 S3E-1222-06N cooling tower (471 tons, 2.1 MW) — modelled | Baltimore Aircoil Product & Application Handbook volume VI, Series 3000 engineering data — the model's own row (nominal tonnage, airflow in CFM, fan motor, dimensions) and the sheet's own rating note: a nominal ton is 3 USGPM of water cooled from 95 °F to 85 °F at a 78 °F entering wet-bulb temperature (docs/bac-source.json) |
| Baltimore Aircoil VFL-036-32M closed-circuit cooler (56 tons, 246 kW) — modelled | Baltimore Aircoil Product & Application Handbook volume VI, Series V closed circuit engineering data — the model's own row (nominal tonnage, airflow in CFM, fan motor, dimensions) and the sheet's own rating note: a nominal ton is 3 USGPM of water cooled from 95 °F to 85 °F at a 78 °F entering wet-bulb temperature (docs/bac-source.json) |
Showing 1–24 of 677
Cooling tower — 202 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 6.8 m³/s of air.
Cooling tower — 219 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 7.6 m³/s of air.
Cooling tower — 254 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 8.7 m³/s of air.
Cooling tower — 298 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 10.2 m³/s of air.
Cooling tower — 280 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 8.9 m³/s of air.
Cooling tower — 324 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 10.3 m³/s of air.
Cooling tower — 381 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 12.1 m³/s of air.
Cooling tower — 416 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 13.7 m³/s of air.
Cooling tower — 425 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 13.5 m³/s of air.
Cooling tower — 504 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 16.0 m³/s of air.
Cooling tower — 570 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 18.1 m³/s of air.
Cooling tower — 596 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 19.7 m³/s of air.
Cooling tower — 613 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 19.3 m³/s of air.
Cooling tower — 701 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 22.2 m³/s of air.
Cooling tower — 767 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 24.3 m³/s of air.
Cooling tower — 841 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 27.8 m³/s of air.
Cooling tower — 863 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 24.2 m³/s of air.
Cooling tower — 946 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 26.6 m³/s of air.
Cooling tower — 1052 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 30.8 m³/s of air.
Cooling tower — 1126 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 33.0 m³/s of air.
Cooling tower — 1236 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 31.3 m³/s of air.
Cooling tower — 2471 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 62.5 m³/s of air.
Cooling tower — 1354 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 34.0 m³/s of air.
Cooling tower — 2708 kW rejected, water 35.0 to 29.4 °C at a 25.6 °C wet bulb, 68.0 m³/s of air.
Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.