Baltimore Aircoil VFL-036-32M closed-circuit cooler (56 tons, 246 kW) — modelled

Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Source: Baltimore Aircoil Product & Application Handbook volume VI, Series V closed circuit engineering data — the model's own row (nominal tonnage, airflow in CFM, fan motor, dimensions) and the sheet's own rating note: a nominal ton is 3 USGPM of water cooled from 95 °F to 85 °F at a 78 °F entering wet-bulb temperature (docs/bac-source.json). The figures below come from this model run against that data; the manufacturer has not reviewed them. Are you Baltimore Aircoil? Claim this page.

CTI STD-201 (validation C11K-00R03) ✓ verified — this model is named in the certification programme's own public register. It certifies the manufacturer's machine against their published ratings; it says nothing about the model of it that runs here, which is validated separately.

by HVAC Builder

Open this system in HVAC Builder Load it into the 3D builder, adjust it to your project, and solve it against your own climate — or drop it into a building model and simulate a full year.

A closed-circuit cooler from BAC's Series V range: the loop fluid runs inside a coil under a recirculating spray and never touches the air, which is what a process loop or a heat-pump condenser loop wants. Rated on the same basis as the open towers — 168 USGPM cooled from 95 to 85 °F at a 78 °F entering wet bulb — on 13.8 m³/s of air from a centrifugal fan, with a 1 hp spray pump and 111 gal of coil. Run as an evaporative wet coil: air against the falling spray, the fluid against the air, the two conductances derived from the rating at the split and fluid-side flow exponent BAC's own Series V closed-circuit performance table picks — 4 and −0.6, the spray film outside the tube being much of the fluid side's resistance. Modelled from the manufacturer's published data — not verified by Baltimore Aircoil. Published as an example; the figures below are solved from this model.

Example200–300 kW heat rejectionEU

Example system. Published by HVAC Builder to show suppliers what their own page looks like. There is no company behind it and it is not a product offer — the specification is generic and the performance is solved from the model on this page.

Design-point performance

244.3 kWheat rejected
14.9 kWelectrical power
486 l/hwater use

Solved from this example's own model as it is published — the same numbers a supplier's page shows for their machine.

Component schedule

ComponentKindDuty
VFL-036-32M fillWet pack-244.3 kW
VFL-036-32M fanFan-14.9 kW

Are you a manufacturer?