1283 listing(s) in HVAC Builder's catalog from Embraco's published data, selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; Embraco has not claimed it.
Compressor maps by refrigerant: R134a 518, R600a 315, R290 285, R404A 141, R22 11, R1234yf 10, R422D 2, R502 1.
Claim this page from the supplier portal: register as a supplier (company name and contact email), open the Company tab and claim the brand. The page and its listings are then yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the supplier portal
Showing 97–120 of 141
R404A compressor — 2.7 kW cooling, 1.47 kW input, COP 1.86 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 2.4 kW cooling, 1.45 kW input, COP 1.68 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 2.7 kW cooling, 1.67 kW input, COP 1.62 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 2.6 kW cooling, 1.37 kW input, COP 1.93 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 2.6 kW cooling, 1.37 kW input, COP 1.93 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 2.4 kW cooling, 1.45 kW input, COP 1.68 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 2.7 kW cooling, 1.67 kW input, COP 1.62 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 3.0 kW cooling, 1.73 kW input, COP 1.72 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 3.3 kW cooling, 1.83 kW input, COP 1.82 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 3.5 kW cooling, 2.10 kW input, COP 1.68 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 3.3 kW cooling, 1.83 kW input, COP 1.82 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 3.5 kW cooling, 2.13 kW input, COP 1.66 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 1.5 kW cooling, 0.73 kW input, COP 2.11 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 1.8 kW cooling, 0.98 kW input, COP 1.82 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 1.5 kW cooling, 0.73 kW input, COP 2.04 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 1.7 kW cooling, 1.03 kW input, COP 1.62 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 2.1 kW cooling, 1.20 kW input, COP 1.76 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 2.1 kW cooling, 1.15 kW input, COP 1.79 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 2.1 kW cooling, 1.20 kW input, COP 1.76 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 1.9 kW cooling, 1.10 kW input, COP 1.74 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 2.1 kW cooling, 1.19 kW input, COP 1.72 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 2.7 kW cooling, 1.31 kW input, COP 2.06 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 2.5 kW cooling, 1.40 kW input, COP 1.76 at the AHRI 7.2/54.4 °C rating point.
R404A compressor — 2.4 kW cooling, 1.43 kW input, COP 1.66 at the AHRI 7.2/54.4 °C rating point.
| Embraco hermetic and variable-capacity compressor maps, fitted from the maker's published tables | 1 283 maps from 815 models (R134a 518, R600a 315, R290 285, R404A 141, R22 11, R1234yf 10, R422D 2, R502 1); 178 variable-capacity models with a table per speed | fitted at the order each table's levels determine (three condensing levels: quadratic in tc), the tables are reproduced at a median RMS of 0.08 % (p90 0.20 %); every map reads the standard's own rating point within 0.08 % at the median and 0.4 % at the ninetieth percentile; every carried flow set closes the identity once the rating's own return-gas and liquid temperatures are read off the node (ASHRAE rates with the liquid at 32.2 °C, 22 K under the condenser). 72 tables withheld and listed by reason: blend groups published as one table, variable-capacity models with fewer than three speeds tabulated, three with a COP under 0.5 at the rating point, three duplicates |
From the validation page; every row is held by a test.
Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.