Greenheck Unclaimed
28 listing(s) in HVAC Builder's catalog from Greenheck's published data, selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; Greenheck has not claimed it.
- Fans — 28
Are you Greenheck?
Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. We confirm each claim by hand before it takes effect; from then the page and its listings are yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page
Listings
Showing 1–24 of 28
Greenheck GB-098 belt-drive centrifugal roof downblast exhaust fan (1725 rpm, 1/4 HP)
Fan rated 0.25 m³/s at 0.20 kW.
Greenheck GB-099 belt-drive centrifugal roof downblast exhaust fan (1725 rpm, 1/4 HP)
Fan rated 0.33 m³/s at 0.27 kW.
Greenheck GB-100 belt-drive centrifugal roof downblast exhaust fan (1800 rpm, 1/3 HP)
Fan rated 0.37 m³/s at 0.30 kW.
Greenheck GB-100HP belt-drive high-pressure centrifugal roof downblast exhaust fan (2550 rpm, 1/2 HP)
Fan rated 0.30 m³/s at 0.48 kW.
Greenheck GB-120 belt-drive centrifugal roof downblast exhaust fan (1725 rpm, 1/2 HP)
Fan rated 0.56 m³/s at 0.45 kW.
Greenheck GB-130 belt-drive centrifugal roof downblast exhaust fan (1725 rpm, 3/4 HP)
Fan rated 0.70 m³/s at 0.53 kW.
Greenheck GB-140 belt-drive centrifugal roof downblast exhaust fan (1725 rpm, 1 HP)
Fan rated 0.86 m³/s at 0.87 kW.
Greenheck GB-140HP belt-drive high-pressure centrifugal roof downblast exhaust fan (2170 rpm, 3/4 HP)
Fan rated 0.49 m³/s at 0.72 kW.
Greenheck GB-160 belt-drive centrifugal roof downblast exhaust fan (1575 rpm, 1-1/2 HP)
Fan rated 1.51 m³/s at 1.33 kW.
Greenheck GB-160HP belt-drive high-pressure centrifugal roof downblast exhaust fan (1740 rpm, 1 HP)
Fan rated 0.69 m³/s at 0.85 kW.
Greenheck GB-180 belt-drive centrifugal roof downblast exhaust fan (1460 rpm, 2 HP)
Fan rated 1.78 m³/s at 1.74 kW.
Greenheck GB-180HP belt-drive high-pressure centrifugal roof downblast exhaust fan (1700 rpm, 2 HP)
Fan rated 1.43 m³/s at 1.78 kW.
Greenheck GB-200 belt-drive centrifugal roof downblast exhaust fan (1200 rpm, 2 HP)
Fan rated 1.45 m³/s at 1.46 kW.
Greenheck GB-200HP belt-drive high-pressure centrifugal roof downblast exhaust fan (1625 rpm, 3 HP)
Fan rated 1.82 m³/s at 2.60 kW.
Greenheck GB-220 belt-drive centrifugal roof downblast exhaust fan (985 rpm, 2 HP)
Fan rated 2.30 m³/s at 1.69 kW.
Greenheck GB-220HP belt-drive high-pressure centrifugal roof downblast exhaust fan (1230 rpm, 3 HP)
Fan rated 2.01 m³/s at 2.52 kW.
Greenheck GB-240 belt-drive centrifugal roof downblast exhaust fan (910 rpm, 2 HP)
Fan rated 2.54 m³/s at 1.70 kW.
Greenheck GB-240HP belt-drive high-pressure centrifugal roof downblast exhaust fan (1240 rpm, 3 HP)
Fan rated 2.25 m³/s at 2.53 kW.
Greenheck GB-260 belt-drive centrifugal roof downblast exhaust fan (835 rpm, 3 HP)
Fan rated 2.84 m³/s at 2.44 kW.
Greenheck GB-300 belt-drive centrifugal roof downblast exhaust fan (890 rpm, 5 HP)
Fan rated 3.76 m³/s at 3.78 kW.
Greenheck GB-300HP belt-drive high-pressure centrifugal roof downblast exhaust fan (1065 rpm, 5 HP)
Fan rated 3.09 m³/s at 4.17 kW.
Greenheck GB-330 belt-drive centrifugal roof downblast exhaust fan (700 rpm, 5 HP)
Fan rated 4.81 m³/s at 4.12 kW.
Greenheck GB-360 belt-drive centrifugal roof downblast exhaust fan (685 rpm, 5 HP)
Fan rated 5.72 m³/s at 4.25 kW.
Greenheck GB-360HP belt-drive high-pressure centrifugal roof downblast exhaust fan (855 rpm, 7-1/2 HP)
Fan rated 4.89 m³/s at 6.00 kW.
How the model reads against Greenheck's data
| Fan power through the fan laws, one curve per fan from a US multi-rating table | 1 832 cells over 28 fans from the Models G and GB catalog, Rev 11 (August 2022); 10 withheld by name | every held cell's BHP within 2 % plus the half-hundredth it is printed to (the worst at 0.94 of that band; one cell from 0.5 BHP past a bare 2 %, the GB-100HP at 2550 rpm and 1.75 in., 2.2 % low) and its speed within 0.37 %, read back by the solver's own fan-law solve; RMS 0.39 % on power over the 1 263 cells from 0.5 BHP up. Every held BHP sits under its page's maximum-BHP law, each listing's power curve peaks at 0.97–1.01 of it at the reference speed, and every belt motor carries it within its 1.15 service factor. Withheld: four row-end cells past the fan's pressure peak and six printed slips — three GB-130 points printed under the wrong static; two GB-480 BHP figures off their own cfm: 3.66 at 393 rpm and 0.125 in., where the 360 and 415 rpm rows scaled by the fan laws give 3.96, and 3.21 at 360 rpm and 0.625 in., over the page's own law, where the fan laws read 3.12; and the GB-540's 1 250 cfm at 175 rpm and 0.125 in., where its own 0.65 BHP and the 195 rpm row put the point at about 12 400 cfm, a dropped digit |
From the validation page; every row is held by a test.
Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.