Greenheck Unclaimed
28 listing(s) in HVAC Builder's catalog from Greenheck's published data, selectable in the builder and solved with the catalog's own figures. This page is listed by HVAC Builder from published data; Greenheck has not claimed it.
- Fans — 28
Are you Greenheck?
Claim this page from the app's Company page: register as a supplier (company name and contact email), open the Profile sub-tab and claim the brand. We confirm each claim by hand before it takes effect; from then the page and its listings are yours — attributed to your company, quote requests for designs that use them reach whoever you name with the design attached, and any listing is yours to edit or withdraw. No charge, no commission. Open the Company page
Listings
Showing 25–28 of 28
Greenheck GB-420 belt-drive centrifugal roof downblast exhaust fan (600 rpm, 7-1/2 HP)
Fan rated 7.83 m³/s at 6.26 kW.
Greenheck GB-480 belt-drive centrifugal roof downblast exhaust fan (485 rpm, 7-1/2 HP)
Fan rated 9.21 m³/s at 6.14 kW.
Greenheck GB-500 belt-drive centrifugal roof downblast exhaust fan (460 rpm, 10 HP)
Fan rated 11.94 m³/s at 8.34 kW.
Greenheck GB-540 belt-drive centrifugal roof downblast exhaust fan (505 rpm, 15 HP)
Fan rated 12.63 m³/s at 11.90 kW.
How the model reads against Greenheck's data
| Fan power through the fan laws, one curve per fan from a US multi-rating table | 1 832 cells over 28 fans from the Models G and GB catalog, Rev 11 (August 2022); 10 withheld by name | every held cell's BHP within 2 % plus the half-hundredth it is printed to (the worst at 0.94 of that band; one cell from 0.5 BHP past a bare 2 %, the GB-100HP at 2550 rpm and 1.75 in., 2.2 % low) and its speed within 0.37 %, read back by the solver's own fan-law solve; RMS 0.39 % on power over the 1 263 cells from 0.5 BHP up. Every held BHP sits under its page's maximum-BHP law, each listing's power curve peaks at 0.97–1.01 of it at the reference speed, and every belt motor carries it within its 1.15 service factor. Withheld: four row-end cells past the fan's pressure peak and six printed slips — three GB-130 points printed under the wrong static; two GB-480 BHP figures off their own cfm: 3.66 at 393 rpm and 0.125 in., where the 360 and 415 rpm rows scaled by the fan laws give 3.96, and 3.21 at 360 rpm and 0.625 in., over the page's own law, where the fan laws read 3.12; and the GB-540's 1 250 cfm at 175 rpm and 0.125 in., where its own 0.65 BHP and the 195 rpm row put the point at about 12 400 cfm, a dropped digit |
From the validation page; every row is held by a test.
Listed from published data with the source named on every entry; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.