Embraco EMY6135Y (R600a hermetic, HBP, EN12900, 50-60 Hz)

Compressor — R600a compressor — 0.42 kW cooling, 0.18 kW input, COP 2.28 at the AHRI 7.2/54.4 °C rating point.

An Embraco listing, from the manufacturer's published data.

Units: SI · US customary

Published specification

ModelEmbraco EMY6135Y (R600a hermetic, HBP, EN12900, 50-60 Hz)
RefrigerantR600a
Performance dataAHRI 540 / EN 12900 10-coefficient map
Reference superheat / subcool22.5 / 0.0 K
Cooling capacity @ 7.2/54.4 °C0.42 kW
Input power @ 7.2/54.4 °C0.18 kW
COP @ 7.2/54.4 °C2.28

The map across its envelope

AHRI 540 / EN 12900 ten-coefficient polynomials in evaporating and condensing temperature, rated at 22.5 K superheat and 0.0 K subcooling; the solver corrects them to the operating superheat and subcooling. Envelope: the manufacturer's 5-sided polygon. The mass-flow coefficient set is published too, and the solver checks it against the capacity set.

te / tc °CCapacity kWPower kWCOP
7.2 / 54.40.420.182.28
-10 / 400.250.112.23
-5 / 400.310.132.49
5 / 400.470.153.09

The rating point and three conditions across the published envelope. The whole map — every condition, the envelope and the curves — is in the builder: open this machine in the app. It solves any point inside the envelope, and warns past it.

Open this compressor in the app — the compressor-map tab, with its rating at any condition, its envelope, capacity and power lines and curves plotted, and the refrigerant's pressure–temperature chart a click away; or open the builder and pick it from the catalog picker — the solver runs it with the catalog's own figures, at your design point or across a year of weather.

Same family

CompressorEmbraco EMY6135Y (R600a hermetic, HBP, EN12900, 50 Hz)R600a

All 65 Embraco EMY models

How the model reads against this maker's data

Embraco hermetic and variable-capacity compressor maps, fitted from the maker's published tables1 283 maps from 815 models (R134a 518, R600a 315, R290 285, R404A 141, R22 11, R1234yf 10, R422D 2, R502 1); 178 variable-capacity models with a table per speedfitted at the order each table's levels determine (three condensing levels: quadratic in tc), the tables are reproduced at a median RMS of 0.08 % (p90 0.20 %); every map reads the standard's own rating point within 0.08 % at the median and 0.4 % at the ninetieth percentile; every carried flow set closes the identity once the rating's own return-gas and liquid temperatures are read off the node (ASHRAE rates with the liquid at 32.2 °C, 22 K under the condenser). 72 tables withheld and listed by reason: blend groups published as one table, variable-capacity models with fewer than three speeds tabulated, three with a COP under 0.5 at the rating point, three duplicates

From the validation page; every row is held by a test.

Listed from published data; a listing's figures are the manufacturer's, the model that runs them is ours. Solver results never depend on who has claimed what.