All categories

Compressors

Compressors from their makers and suppliers, with the specification each publishes and a quote form on every listing.

The builder models these: pick one into a design and it solves on the listing's figures.

Suppliers 45Systems 3,474Components 15,410Accessories 0

Showing 3,289–3,312 of 14,438

NameManufacturerRatingMarketsOpen in the builder
Tecumseh FH2511P-XG1A (R452A hermetic, LBP, EN12900, 60 Hz) CatalogTecumsehR452A compressor — 1.4 kW cooling, 1.40 kW input, COP 0.97 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 4YRNR27ME-TSK (R454C Discus recip, 50 Hz, MD) CatalogCopelandR454C compressor — 36.8 kW cooling, 13.39 kW input, COP 2.75 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss HRM038U2 (R22 scroll, 60 Hz, A/C) CatalogDanfossR22 compressor — 11.1 kW cooling, 3.39 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco FFUS80HAK (R134a hermetic, LBP, EN12900, 60 Hz) CatalogEmbracoR134a compressor — 0.17 kW cooling, 0.13 kW input, COP 1.29 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF29A3G-Q100 (R22 low-temperature freezing scroll, 60 Hz, 220 V 1P) CatalogInvotechR22 compressor — 3.9 kW cooling, 3.13 kW input, COP 1.25 at -30/45 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Tecumseh AE2420Z-DS1B (R404A hermetic, LBP, ASHRAE, 60 Hz) CatalogTecumsehR404A compressor — 0.34 kW cooling, 0.36 kW input, COP 0.97 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 6DBNR32ML-TSK (R407C Discus recip, 60 Hz, AC) CatalogCopelandR407C compressor — 99.6 kW cooling, 30.99 kW input, COP 3.21 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Danfoss HRP042T1 (R407C scroll, 60 Hz, A/C) CatalogDanfossR407C compressor — 11.8 kW cooling, 3.70 kW input, COP 3.20 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco FMFT411U (R290 variable-capacity hermetic, LBP, EN12900, 50-60 Hz) CatalogEmbracoR290 compressor — 0.61 kW cooling, 0.38 kW input, COP 1.59 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH175T8-100 (R407C air-conditioning scroll, 60 Hz, 575 V 3P) CatalogInvotechR407C compressor — 20.3 kW cooling, 6.19 kW input, COP 3.28 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AG2518U-TZ1A (R290 hermetic, LBP, EN12900, 60 Hz) CatalogTecumsehR290 compressor — 2.2 kW cooling, 2.21 kW input, COP 0.98 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 6DBXR32ME-TSK (R407C Discus recip, 50 Hz, MD) CatalogCopelandR407C compressor — 40.2 kW cooling, 14.90 kW input, COP 2.70 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss LLZ013T2C (R455A scroll, 60 Hz) CatalogDanfossR455A compressor — 3.8 kW cooling, 2.14 kW input, COP 1.76 at -30/30 °C (evaporating/condensing), inside its published envelope.Open in the builder
Embraco NEK2125GK (R404A hermetic, LBP, EN12900, 50-60 Hz) CatalogEmbracoR404A compressor — 0.22 kW cooling, 0.21 kW input, COP 1.02 at -35/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM43A2G-102 (R22 medium-temperature refrigeration scroll, 50 Hz, 220 V 1P) CatalogInvotechR22 compressor — 6.9 kW cooling, 2.60 kW input, COP 2.65 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AGB4561ZKZ (R404A hermetic, HBP, EN12900, 60 Hz) CatalogTecumsehR404A compressor — 14.2 kW cooling, 7.18 kW input, COP 1.98 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 6DGNR37ME-TSN (R407F Discus recip, 50 Hz, MD) CatalogCopelandR407F compressor — 53.2 kW cooling, 20.05 kW input, COP 2.65 at -15/35 °C (evaporating/condensing), inside its published envelope.EU, APACOpen in the builder
Danfoss MLM048T4 (R22 scroll, 50 Hz, MT) CatalogDanfossR22 compressor — 17.9 kW cooling, 5.60 kW input, COP 3.21 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NEU2168GJ (R404A hermetic, LBP, EN12900, 50 Hz) CatalogEmbracoR404A compressor — 0.42 kW cooling, 0.37 kW input, COP 1.15 at -35/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YW320C8-100 (R410A heat-pump water heater scroll, 60 Hz, 575 V 3P) CatalogInvotechR410A compressor — 41.8 kW cooling, 13.64 kW input, COP 3.06 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AJ2440Z-FZ3C (R452A hermetic, LBP, EN12900, 50 Hz) CatalogTecumsehR452A compressor — 0.38 kW cooling, 0.44 kW input, COP 0.85 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 6DGXR37ME-TSN (R407F Discus recip, 50 Hz, AC) CatalogCopelandR407F compressor — 103.8 kW cooling, 34.00 kW input, COP 3.05 at the AHRI 7.2/54.4 °C rating point.EU, APACOpen in the builder
Danfoss MLZ015T2 (R134a scroll, 50 Hz, MT) CatalogDanfossR134a compressor — 3.7 kW cooling, 1.27 kW input, COP 2.91 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NJ9226E (R22 hermetic, HBP, EN12900, 60 Hz) CatalogEmbracoR22 compressor — 2.7 kW cooling, 1.24 kW input, COP 2.15 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
‹ Previous1…136137138139140…602Next ›

Manufacturers publish from the supplier portal, or bulk-import a whole range over MCP. How it works for component vendors