NameManufacturerRatingMarketsOpen in the builder
Embraco EMY60HSC (R134a hermetic, LBP, ASHRAE, 60 Hz) CatalogEmbracoR134a compressor — 0.14 kW cooling, 0.09 kW input, COP 1.52 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF80E1G-Q100 (R404A low-temperature freezing scroll, 50 Hz, 380 V 3P) CatalogInvotechR404A compressor — 8.9 kW cooling, 7.22 kW input, COP 1.24 at -30/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Tecumseh AGB4581ZKZ (R404A hermetic, HBP, EN12900, 50 Hz) CatalogTecumsehR404A compressor — 16.1 kW cooling, 7.97 kW input, COP 2.02 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 2YC3R51KL-TFC (R454C Discus recip, 60 Hz, MD) CatalogCopelandR454C compressor — 8.2 kW cooling, 2.93 kW input, COP 2.79 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss PSH026-3G (R454B scroll, 60 Hz) CatalogDanfossR454B compressor — 33.5 kW cooling, 11.13 kW input, COP 3.01 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NEK6160Z (R134a hermetic, HBP, EN12900, 60 Hz) CatalogEmbracoR134a compressor — 0.76 kW cooling, 0.36 kW input, COP 2.11 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH69A2-102 (R22 air-conditioning scroll, 50 Hz, 220 V 1P) CatalogInvotechR22 compressor — 6.9 kW cooling, 2.25 kW input, COP 3.08 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Tecumseh AJ2464P-HZ3A (R454C hermetic, LBP, EN12900, 60 Hz) CatalogTecumsehR454C compressor — 0.82 kW cooling, 0.87 kW input, COP 0.95 at -30/50 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 2YD3R59KL-TFC (R454C Discus recip, 60 Hz, MD) CatalogCopelandR454C compressor — 9.5 kW cooling, 3.40 kW input, COP 2.78 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss SH180-9 (R410A scroll, 60 Hz, A/C) CatalogDanfossR410A compressor — 53.7 kW cooling, 16.45 kW input, COP 3.27 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NEU6212GK (R404A hermetic, MBP, EN12900, 60 Hz) CatalogEmbracoR404A compressor — 1.4 kW cooling, 0.72 kW input, COP 1.96 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YM70E7G-100 (R452A medium-temperature refrigeration scroll, 60 Hz, 220 V 3P) CatalogInvotechR452A compressor — 12.9 kW cooling, 5.31 kW input, COP 2.42 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh FH4522U-XG1A (R290 hermetic, HBP, EN12900, 60 Hz) CatalogTecumsehR290 compressor — 5.6 kW cooling, 2.05 kW input, COP 2.75 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 2YL3F15KL-TFC (R454C Discus recip, 60 Hz, LD) CatalogCopelandR454C compressor — 4.3 kW cooling, 2.52 kW input, COP 1.72 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss SM148-3 (R22 scroll, 60 Hz, A/C) CatalogDanfossR22 compressor — 43.8 kW cooling, 13.01 kW input, COP 3.37 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco NT6217GK (R404A hermetic, MBP, EN12900, 60 Hz) CatalogEmbracoR404A compressor — 1.8 kW cooling, 0.98 kW input, COP 1.82 at the AHRI 7.2/54.4 °C rating point.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YF80E1G-Q100 (R404A low-temperature freezing scroll, 60 Hz, 460 V 3P) CatalogInvotechR404A compressor — 10.7 kW cooling, 8.66 kW input, COP 1.24 at -30/45 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Tecumseh AE4430Z-GS1A (R404A hermetic, HBP, ASHRAE, 50 Hz) CatalogTecumsehR404A compressor — 0.83 kW cooling, 0.35 kW input, COP 2.36 at the AHRI 7.2/54.4 °C rating point.EUOpen in the builder
Copeland 3DA3F28KL-TFC (R407A Discus recip, 60 Hz, LD) CatalogCopelandR407A compressor — 6.6 kW cooling, 3.79 kW input, COP 1.73 at -35/30 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder
Danfoss SZ110-6 (R134a scroll, 50 Hz, HT) CatalogDanfossR134a compressor — 17.6 kW cooling, 5.40 kW input, COP 3.25 at the AHRI 7.2/54.4 °C rating point.Open in the builder
Embraco EM2U3121Z (R134a hermetic, MBP, EN12900, 50-60 Hz) CatalogEmbracoR134a compressor — 0.19 kW cooling, 0.14 kW input, COP 1.43 at -30/40 °C (evaporating/condensing), inside its published envelope.APAC, CN, EU, LATAM, NAOpen in the builder
Invotech YH69A3-100 (R22 air-conditioning scroll, 60 Hz, 220 V 1P) CatalogInvotechR22 compressor — 8.3 kW cooling, 2.66 kW input, COP 3.12 at the AHRI 7.2/54.4 °C rating point.NAOpen in the builder
Tecumseh AG2525Z-TZ1A (R452A hermetic, LBP, EN12900, 60 Hz) CatalogTecumsehR452A compressor — 3.0 kW cooling, 2.99 kW input, COP 1.00 at -35/45 °C (evaporating/condensing), inside its published envelope.EUOpen in the builder
Copeland 3DADF28KE-TFD (R513A Discus recip, 60 Hz, MD) CatalogCopelandR513A compressor — 11.2 kW cooling, 4.27 kW input, COP 2.63 at -15/35 °C (evaporating/condensing), inside its published envelope.NAOpen in the builder